ABAP Select data from SAP table PLMT_TS_FMEA_ACT_TYPE into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PLMT_TS_FMEA_ACT_TYPE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PLMT_TS_FMEA_ACT_TYPE. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PLMT_TS_FMEA_ACT_TYPE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PLMT_TS_FMEA_ACT_TYPE TYPE STANDARD TABLE OF PLMT_TS_FMEA_ACT_TYPE, WA_PLMT_TS_FMEA_ACT_TYPE TYPE PLMT_TS_FMEA_ACT_TYPE, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <PLMT_TS_FMEA_ACT_TYPE> TYPE PLMT_TS_FMEA_ACT_TYPE. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_PLMT_TS_FMEA_ACT_TYPE. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM PLMT_TS_FMEA_ACT_TYPE INTO TABLE IT_PLMT_TS_FMEA_ACT_TYPE. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM PLMT_TS_FMEA_ACT_TYPE * INTO TABLE @DATA(IT_PLMT_TS_FMEA_ACT_TYPE2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_PLMT_TS_FMEA_ACT_TYPE INDEX 1 INTO DATA(WA_PLMT_TS_FMEA_ACT_TYPE2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_PLMT_TS_FMEA_ACT_TYPE ASSIGNING <PLMT_TS_FMEA_ACT_TYPE>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<PLMT_TS_FMEA_ACT_TYPE>-ASSESSM_PROFIL = 1.
<PLMT_TS_FMEA_ACT_TYPE>-ASSESSMENT_REC = 1.
<PLMT_TS_FMEA_ACT_TYPE>-ASSESSM_RES = 1.
<PLMT_TS_FMEA_ACT_TYPE>-SCORE_REC = 1.
<PLMT_TS_FMEA_ACT_TYPE>-SCORE_RES = 1.
ENDLOOP. LOOP AT IT_PLMT_TS_FMEA_ACT_TYPE INTO WA_PLMT_TS_FMEA_ACT_TYPE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PLMT_TS_FMEA_ACT_TYPE-ASSESSM_RES_OLD, sy-vline,
WA_PLMT_TS_FMEA_ACT_TYPE-SCORE_REC_OLD, sy-vline,
WA_PLMT_TS_FMEA_ACT_TYPE-SCORE_RES_OLD, sy-vline,
WA_PLMT_TS_FMEA_ACT_TYPE-CONFIRMATION, sy-vline,
WA_PLMT_TS_FMEA_ACT_TYPE-MAKAT, sy-vline,
WA_PLMT_TS_FMEA_ACT_TYPE-GRUPPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PLMT_TS_FMEA_ACT_TYPE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PLMT_TS_FMEA_ACT_TYPE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PLMT_TS_FMEA_ACT_TYPE INTO WA_PLMT_TS_FMEA_ACT_TYPE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field VERSION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PLMT_TS_FMEA_ACT_TYPE-VERSION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMT_TS_FMEA_ACT_TYPE-VERSION.
WRITE:/ 'New Value:', ld_input.
*Conversion exit PLMAM, internal->external for field REFERENCE_GUID CALL FUNCTION 'CONVERSION_EXIT_PLMAM_OUTPUT' EXPORTING input = WA_PLMT_TS_FMEA_ACT_TYPE-REFERENCE_GUID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMT_TS_FMEA_ACT_TYPE-REFERENCE_GUID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field QMNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PLMT_TS_FMEA_ACT_TYPE-QMNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMT_TS_FMEA_ACT_TYPE-QMNUM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PLMT_TS_FMEA_ACT_TYPE_STR,
ASSESSM_PROFIL TYPE STRING,
ASSESSMENT_REC TYPE STRING,
ASSESSM_RES TYPE STRING,
SCORE_REC TYPE STRING,
SCORE_RES TYPE STRING,
ASSESSM_RES_OLD TYPE STRING,
SCORE_REC_OLD TYPE STRING,
SCORE_RES_OLD TYPE STRING,
CONFIRMATION TYPE STRING,
MAKAT TYPE STRING,
GRUPPE TYPE STRING,
CODE TYPE STRING,
VERSION TYPE STRING,
ACT_CANCEL TYPE STRING,
REFERENCE_GUID TYPE STRING,
START_ACTION TYPE STRING,
QMNUM TYPE STRING,
FENUM TYPE STRING,
MANUM TYPE STRING,
DUMMY_FMEA_ACT_TYP_INCL_EEW_PS TYPE STRING,END OF T_EKKO_STR. DATA: WA_PLMT_TS_FMEA_ACT_TYPE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PLMT_TS_FMEA_ACT_TYPE_STR-ASSESSM_PROFIL sy-vline
WA_PLMT_TS_FMEA_ACT_TYPE_STR-ASSESSMENT_REC sy-vline
WA_PLMT_TS_FMEA_ACT_TYPE_STR-ASSESSM_RES sy-vline
WA_PLMT_TS_FMEA_ACT_TYPE_STR-SCORE_REC sy-vline
WA_PLMT_TS_FMEA_ACT_TYPE_STR-SCORE_RES sy-vline
WA_PLMT_TS_FMEA_ACT_TYPE_STR-ASSESSM_RES_OLD sy-vline
WA_PLMT_TS_FMEA_ACT_TYPE_STR-SCORE_REC_OLD sy-vline
WA_PLMT_TS_FMEA_ACT_TYPE_STR-SCORE_RES_OLD sy-vline
WA_PLMT_TS_FMEA_ACT_TYPE_STR-CONFIRMATION sy-vline
WA_PLMT_TS_FMEA_ACT_TYPE_STR-MAKAT sy-vline
WA_PLMT_TS_FMEA_ACT_TYPE_STR-GRUPPE sy-vline
WA_PLMT_TS_FMEA_ACT_TYPE_STR-CODE sy-vline
WA_PLMT_TS_FMEA_ACT_TYPE_STR-VERSION sy-vline
WA_PLMT_TS_FMEA_ACT_TYPE_STR-ACT_CANCEL sy-vline
WA_PLMT_TS_FMEA_ACT_TYPE_STR-REFERENCE_GUID sy-vline
WA_PLMT_TS_FMEA_ACT_TYPE_STR-START_ACTION sy-vline
WA_PLMT_TS_FMEA_ACT_TYPE_STR-QMNUM sy-vline
WA_PLMT_TS_FMEA_ACT_TYPE_STR-FENUM sy-vline
WA_PLMT_TS_FMEA_ACT_TYPE_STR-MANUM sy-vline
WA_PLMT_TS_FMEA_ACT_TYPE_STR-DUMMY_FMEA_ACT_TYP_INCL_EEW_PS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.