ABAP Select data from SAP table PMXLIST_FIC_CE into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PMXLIST_FIC_CE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PMXLIST_FIC_CE. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PMXLIST_FIC_CE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PMXLIST_FIC_CE TYPE STANDARD TABLE OF PMXLIST_FIC_CE, WA_PMXLIST_FIC_CE TYPE PMXLIST_FIC_CE, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <PMXLIST_FIC_CE> TYPE PMXLIST_FIC_CE. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_PMXLIST_FIC_CE. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM PMXLIST_FIC_CE INTO TABLE IT_PMXLIST_FIC_CE. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM PMXLIST_FIC_CE * INTO TABLE @DATA(IT_PMXLIST_FIC_CE2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_PMXLIST_FIC_CE INDEX 1 INTO DATA(WA_PMXLIST_FIC_CE2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_PMXLIST_FIC_CE ASSIGNING <PMXLIST_FIC_CE>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<PMXLIST_FIC_CE>-RFC = 1.
<PMXLIST_FIC_CE>-BUKRS = 1.
<PMXLIST_FIC_CE>-BUTXT = 1.
<PMXLIST_FIC_CE>-WERKS = 1.
<PMXLIST_FIC_CE>-DES_WERKS = 1.
ENDLOOP. LOOP AT IT_PMXLIST_FIC_CE INTO WA_PMXLIST_FIC_CE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PMXLIST_FIC_CE-BTRTL, sy-vline,
WA_PMXLIST_FIC_CE-DES_BTRTL, sy-vline,
WA_PMXLIST_FIC_CE-ABKRS, sy-vline,
WA_PMXLIST_FIC_CE-DES_ABKRS, sy-vline,
WA_PMXLIST_FIC_CE-PERSK, sy-vline,
WA_PMXLIST_FIC_CE-DES_PERSK, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PMXLIST_FIC_CE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PMXLIST_FIC_CE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PMXLIST_FIC_CE INTO WA_PMXLIST_FIC_CE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit PIDEX, internal->external for field PERSONID_EXT CALL FUNCTION 'CONVERSION_EXIT_PIDEX_OUTPUT' EXPORTING input = WA_PMXLIST_FIC_CE-PERSONID_EXT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PMXLIST_FIC_CE-PERSONID_EXT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PMXLIST_FIC_CE_STR,
RFC TYPE STRING,
BUKRS TYPE STRING,
BUTXT TYPE STRING,
WERKS TYPE STRING,
DES_WERKS TYPE STRING,
BTRTL TYPE STRING,
DES_BTRTL TYPE STRING,
ABKRS TYPE STRING,
DES_ABKRS TYPE STRING,
PERSK TYPE STRING,
DES_PERSK TYPE STRING,
PERSONID_EXT TYPE STRING,
PERNR TYPE STRING,
ENAME TYPE STRING,
DLART TYPE STRING,
OBJPS TYPE STRING,
BORD TYPE STRING,
CSAL TYPE STRING,
IORD TYPE STRING,
TCIA TYPE STRING,
SPRES TYPE STRING,
IMERC TYPE STRING,
IREAL TYPE STRING,
DIFER TYPE STRING,
NEWBORD TYPE STRING,
SALFIC TYPE STRING,
IMPFIC TYPE STRING,
INGFIC TYPE STRING,
NUMPRES TYPE STRING,END OF T_EKKO_STR. DATA: WA_PMXLIST_FIC_CE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PMXLIST_FIC_CE_STR-RFC sy-vline
WA_PMXLIST_FIC_CE_STR-BUKRS sy-vline
WA_PMXLIST_FIC_CE_STR-BUTXT sy-vline
WA_PMXLIST_FIC_CE_STR-WERKS sy-vline
WA_PMXLIST_FIC_CE_STR-DES_WERKS sy-vline
WA_PMXLIST_FIC_CE_STR-BTRTL sy-vline
WA_PMXLIST_FIC_CE_STR-DES_BTRTL sy-vline
WA_PMXLIST_FIC_CE_STR-ABKRS sy-vline
WA_PMXLIST_FIC_CE_STR-DES_ABKRS sy-vline
WA_PMXLIST_FIC_CE_STR-PERSK sy-vline
WA_PMXLIST_FIC_CE_STR-DES_PERSK sy-vline
WA_PMXLIST_FIC_CE_STR-PERSONID_EXT sy-vline
WA_PMXLIST_FIC_CE_STR-PERNR sy-vline
WA_PMXLIST_FIC_CE_STR-ENAME sy-vline
WA_PMXLIST_FIC_CE_STR-DLART sy-vline
WA_PMXLIST_FIC_CE_STR-OBJPS sy-vline
WA_PMXLIST_FIC_CE_STR-BORD sy-vline
WA_PMXLIST_FIC_CE_STR-CSAL sy-vline
WA_PMXLIST_FIC_CE_STR-IORD sy-vline
WA_PMXLIST_FIC_CE_STR-TCIA sy-vline
WA_PMXLIST_FIC_CE_STR-SPRES sy-vline
WA_PMXLIST_FIC_CE_STR-IMERC sy-vline
WA_PMXLIST_FIC_CE_STR-IREAL sy-vline
WA_PMXLIST_FIC_CE_STR-DIFER sy-vline
WA_PMXLIST_FIC_CE_STR-NEWBORD sy-vline
WA_PMXLIST_FIC_CE_STR-SALFIC sy-vline
WA_PMXLIST_FIC_CE_STR-IMPFIC sy-vline
WA_PMXLIST_FIC_CE_STR-INGFIC sy-vline
WA_PMXLIST_FIC_CE_STR-NUMPRES sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.