ABAP Select data from SAP table POSWPSA_CH into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP POSWPSA_CH table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to POSWPSA_CH. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the POSWPSA_CH table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_POSWPSA_CH TYPE STANDARD TABLE OF POSWPSA_CH, WA_POSWPSA_CH TYPE POSWPSA_CH, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <POSWPSA_CH> TYPE POSWPSA_CH. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_POSWPSA_CH. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM POSWPSA_CH INTO TABLE IT_POSWPSA_CH. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM POSWPSA_CH * INTO TABLE @DATA(IT_POSWPSA_CH2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_POSWPSA_CH INDEX 1 INTO DATA(WA_POSWPSA_CH2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_POSWPSA_CH ASSIGNING <POSWPSA_CH>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<POSWPSA_CH>-SEGNUM_CHG = 1.
<POSWPSA_CH>-SEGFLD = 1.
<POSWPSA_CH>-OLD_VALUE = 1.
<POSWPSA_CH>-NEW_VALUE = 1.
ENDLOOP. LOOP AT IT_POSWPSA_CH INTO WA_POSWPSA_CH. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, ENDLOOP. *Add any further fields from structure WA_POSWPSA_CH you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_POSWPSA_CH TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_POSWPSA_CH INTO WA_POSWPSA_CH. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_POSWPSA_CH_STR,
SEGNUM_CHG TYPE STRING,
SEGFLD TYPE STRING,
OLD_VALUE TYPE STRING,
NEW_VALUE TYPE STRING,END OF T_EKKO_STR. DATA: WA_POSWPSA_CH_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_POSWPSA_CH_STR-SEGNUM_CHG sy-vline
WA_POSWPSA_CH_STR-SEGFLD sy-vline
WA_POSWPSA_CH_STR-OLD_VALUE sy-vline
WA_POSWPSA_CH_STR-NEW_VALUE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.