ABAP Select data from SAP table PPE51_1100 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PPE51_1100 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PPE51_1100. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PPE51_1100 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PPE51_1100 TYPE STANDARD TABLE OF PPE51_1100,
      WA_PPE51_1100 TYPE PPE51_1100,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PPE51_1100> TYPE PPE51_1100.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PPE51_1100.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PPE51_1100
  INTO TABLE IT_PPE51_1100.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PPE51_1100
*  INTO TABLE @DATA(IT_PPE51_11002).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PPE51_1100 INDEX 1 INTO DATA(WA_PPE51_11002).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PPE51_1100 ASSIGNING <PPE51_1100>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PPE51_1100>-MOLGA = 1.
<PPE51_1100>-FORML = 1.
<PPE51_1100>-CLASS = 1.
<PPE51_1100>-GENER = 1.
<PPE51_1100>-RESPU = 1.
ENDLOOP.

LOOP AT IT_PPE51_1100 INTO WA_PPE51_1100.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PPE51_1100-RELEA, sy-vline,
WA_PPE51_1100-CDATE, sy-vline,
WA_PPE51_1100-UVERS, sy-vline,
WA_PPE51_1100-UNAME, sy-vline,
WA_PPE51_1100-UDATE, sy-vline,
WA_PPE51_1100-UTIME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PPE51_1100 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PPE51_1100 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PPE51_1100 INTO WA_PPE51_1100. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PPE51_1100_STR,
MOLGA TYPE STRING,
FORML TYPE STRING,
CLASS TYPE STRING,
GENER TYPE STRING,
RESPU TYPE STRING,
RELEA TYPE STRING,
CDATE TYPE STRING,
UVERS TYPE STRING,
UNAME TYPE STRING,
UDATE TYPE STRING,
UTIME TYPE STRING,
R_MAX TYPE STRING,
C_MAX TYPE STRING,
R_USE TYPE STRING,
C_USE TYPE STRING,
COMPR TYPE STRING,
CFLAG TYPE STRING,
WTEXT TYPE STRING,
LTEXT TYPE STRING,
FTEXT TYPE STRING,
FFORM TYPE STRING,END OF T_EKKO_STR. DATA: WA_PPE51_1100_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PPE51_1100_STR-MOLGA sy-vline
WA_PPE51_1100_STR-FORML sy-vline
WA_PPE51_1100_STR-CLASS sy-vline
WA_PPE51_1100_STR-GENER sy-vline
WA_PPE51_1100_STR-RESPU sy-vline
WA_PPE51_1100_STR-RELEA sy-vline
WA_PPE51_1100_STR-CDATE sy-vline
WA_PPE51_1100_STR-UVERS sy-vline
WA_PPE51_1100_STR-UNAME sy-vline
WA_PPE51_1100_STR-UDATE sy-vline
WA_PPE51_1100_STR-UTIME sy-vline
WA_PPE51_1100_STR-R_MAX sy-vline
WA_PPE51_1100_STR-C_MAX sy-vline
WA_PPE51_1100_STR-R_USE sy-vline
WA_PPE51_1100_STR-C_USE sy-vline
WA_PPE51_1100_STR-COMPR sy-vline
WA_PPE51_1100_STR-CFLAG sy-vline
WA_PPE51_1100_STR-WTEXT sy-vline
WA_PPE51_1100_STR-LTEXT sy-vline
WA_PPE51_1100_STR-FTEXT sy-vline
WA_PPE51_1100_STR-FFORM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.