ABAP Select data from SAP table PPEPDV_PVCMP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PPEPDV_PVCMP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PPEPDV_PVCMP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PPEPDV_PVCMP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PPEPDV_PVCMP TYPE STANDARD TABLE OF PPEPDV_PVCMP,
      WA_PPEPDV_PVCMP TYPE PPEPDV_PVCMP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PPEPDV_PVCMP> TYPE PPEPDV_PVCMP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PPEPDV_PVCMP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PPEPDV_PVCMP
  INTO TABLE IT_PPEPDV_PVCMP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PPEPDV_PVCMP
*  INTO TABLE @DATA(IT_PPEPDV_PVCMP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PPEPDV_PVCMP INDEX 1 INTO DATA(WA_PPEPDV_PVCMP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PPEPDV_PVCMP ASSIGNING <PPEPDV_PVCMP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PPEPDV_PVCMP>-MANDT = 1.
<PPEPDV_PVCMP>-PVGUID = 1.
<PPEPDV_PVCMP>-PVNAME = 1.
<PPEPDV_PVCMP>-NAMEID = 1.
<PPEPDV_PVCMP>-PNGUID = 1.
ENDLOOP.

LOOP AT IT_PPEPDV_PVCMP INTO WA_PPEPDV_PVCMP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PPEPDV_PVCMP-PVTYPE, sy-vline,
WA_PPEPDV_PVCMP-APPLOBJ_TYPE, sy-vline,
WA_PPEPDV_PVCMP-TIMSTMP, sy-vline,
WA_PPEPDV_PVCMP-HISTFLG, sy-vline,
WA_PPEPDV_PVCMP-CREADAT, sy-vline,
WA_PPEPDV_PVCMP-CREABY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PPEPDV_PVCMP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PPEPDV_PVCMP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PPEPDV_PVCMP INTO WA_PPEPDV_PVCMP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PVNAME CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPEPDV_PVCMP-PVNAME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPEPDV_PVCMP-PVNAME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPEPDV_PVCMP-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPEPDV_PVCMP-LOGSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPEPDV_PVCMP-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPEPDV_PVCMP-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PPEPDV_PVCMP-QUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPEPDV_PVCMP-QUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ROMEI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PPEPDV_PVCMP-ROMEI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPEPDV_PVCMP-ROMEI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ROKME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PPEPDV_PVCMP-ROKME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPEPDV_PVCMP-ROKME.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PPEPDV_PVCMP_STR,
MANDT TYPE STRING,
PVGUID TYPE STRING,
PVNAME TYPE STRING,
NAMEID TYPE STRING,
PNGUID TYPE STRING,
PVTYPE TYPE STRING,
APPLOBJ_TYPE TYPE STRING,
TIMSTMP TYPE STRING,
HISTFLG TYPE STRING,
CREADAT TYPE STRING,
CREABY TYPE STRING,
CHNGDAT TYPE STRING,
CHNGBY TYPE STRING,
LOGSYS TYPE STRING,
AENNR TYPE STRING,
DELFLG TYPE STRING,
CLINT TYPE STRING,
PVCTYPE TYPE STRING,
CMPID TYPE STRING,
QUANT TYPE STRING,
QUNIT TYPE STRING,
DOCID TYPE STRING,
ROMS1 TYPE STRING,
PRCNT1 TYPE STRING,
ROMS2 TYPE STRING,
PRCNT2 TYPE STRING,
ROMS3 TYPE STRING,
PRCNT3 TYPE STRING,
ROMEI TYPE STRING,
ROMEN TYPE STRING,
ROKME TYPE STRING,
RFORM TYPE STRING,
QUANT_FIX_PD TYPE STRING,
OTYPE_PD TYPE STRING,
PGUID_PD TYPE STRING,
OTYPE_REF_PD TYPE STRING,
PGUID_REF_PD TYPE STRING,
ALTGRP_PD TYPE STRING,
CO_DATA_FLG_PD TYPE STRING,
STDVAR TYPE STRING,
PRIO TYPE STRING,
KNOBJ TYPE STRING,
CUOBJ TYPE STRING,
OTYPE TYPE STRING,
PGUID TYPE STRING,
DMUCNT TYPE STRING,END OF T_EKKO_STR. DATA: WA_PPEPDV_PVCMP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PPEPDV_PVCMP_STR-MANDT sy-vline
WA_PPEPDV_PVCMP_STR-PVGUID sy-vline
WA_PPEPDV_PVCMP_STR-PVNAME sy-vline
WA_PPEPDV_PVCMP_STR-NAMEID sy-vline
WA_PPEPDV_PVCMP_STR-PNGUID sy-vline
WA_PPEPDV_PVCMP_STR-PVTYPE sy-vline
WA_PPEPDV_PVCMP_STR-APPLOBJ_TYPE sy-vline
WA_PPEPDV_PVCMP_STR-TIMSTMP sy-vline
WA_PPEPDV_PVCMP_STR-HISTFLG sy-vline
WA_PPEPDV_PVCMP_STR-CREADAT sy-vline
WA_PPEPDV_PVCMP_STR-CREABY sy-vline
WA_PPEPDV_PVCMP_STR-CHNGDAT sy-vline
WA_PPEPDV_PVCMP_STR-CHNGBY sy-vline
WA_PPEPDV_PVCMP_STR-LOGSYS sy-vline
WA_PPEPDV_PVCMP_STR-AENNR sy-vline
WA_PPEPDV_PVCMP_STR-DELFLG sy-vline
WA_PPEPDV_PVCMP_STR-CLINT sy-vline
WA_PPEPDV_PVCMP_STR-PVCTYPE sy-vline
WA_PPEPDV_PVCMP_STR-CMPID sy-vline
WA_PPEPDV_PVCMP_STR-QUANT sy-vline
WA_PPEPDV_PVCMP_STR-QUNIT sy-vline
WA_PPEPDV_PVCMP_STR-DOCID sy-vline
WA_PPEPDV_PVCMP_STR-ROMS1 sy-vline
WA_PPEPDV_PVCMP_STR-PRCNT1 sy-vline
WA_PPEPDV_PVCMP_STR-ROMS2 sy-vline
WA_PPEPDV_PVCMP_STR-PRCNT2 sy-vline
WA_PPEPDV_PVCMP_STR-ROMS3 sy-vline
WA_PPEPDV_PVCMP_STR-PRCNT3 sy-vline
WA_PPEPDV_PVCMP_STR-ROMEI sy-vline
WA_PPEPDV_PVCMP_STR-ROMEN sy-vline
WA_PPEPDV_PVCMP_STR-ROKME sy-vline
WA_PPEPDV_PVCMP_STR-RFORM sy-vline
WA_PPEPDV_PVCMP_STR-QUANT_FIX_PD sy-vline
WA_PPEPDV_PVCMP_STR-OTYPE_PD sy-vline
WA_PPEPDV_PVCMP_STR-PGUID_PD sy-vline
WA_PPEPDV_PVCMP_STR-OTYPE_REF_PD sy-vline
WA_PPEPDV_PVCMP_STR-PGUID_REF_PD sy-vline
WA_PPEPDV_PVCMP_STR-ALTGRP_PD sy-vline
WA_PPEPDV_PVCMP_STR-CO_DATA_FLG_PD sy-vline
WA_PPEPDV_PVCMP_STR-STDVAR sy-vline
WA_PPEPDV_PVCMP_STR-PRIO sy-vline
WA_PPEPDV_PVCMP_STR-KNOBJ sy-vline
WA_PPEPDV_PVCMP_STR-CUOBJ sy-vline
WA_PPEPDV_PVCMP_STR-OTYPE sy-vline
WA_PPEPDV_PVCMP_STR-PGUID sy-vline
WA_PPEPDV_PVCMP_STR-DMUCNT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.