ABAP Select data from SAP table PPETDP_ECN_MOD_IP into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PPETDP_ECN_MOD_IP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PPETDP_ECN_MOD_IP. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PPETDP_ECN_MOD_IP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PPETDP_ECN_MOD_IP TYPE STANDARD TABLE OF PPETDP_ECN_MOD_IP, WA_PPETDP_ECN_MOD_IP TYPE PPETDP_ECN_MOD_IP, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <PPETDP_ECN_MOD_IP> TYPE PPETDP_ECN_MOD_IP. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_PPETDP_ECN_MOD_IP. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM PPETDP_ECN_MOD_IP INTO TABLE IT_PPETDP_ECN_MOD_IP. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM PPETDP_ECN_MOD_IP * INTO TABLE @DATA(IT_PPETDP_ECN_MOD_IP2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_PPETDP_ECN_MOD_IP INDEX 1 INTO DATA(WA_PPETDP_ECN_MOD_IP2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_PPETDP_ECN_MOD_IP ASSIGNING <PPETDP_ECN_MOD_IP>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<PPETDP_ECN_MOD_IP>-PAGUID = 1.
<PPETDP_ECN_MOD_IP>-AENNR = 1.
<PPETDP_ECN_MOD_IP>-VERSIOID = 1.
<PPETDP_ECN_MOD_IP>-DATEF = 1.
<PPETDP_ECN_MOD_IP>-DURATION = 1.
ENDLOOP. LOOP AT IT_PPETDP_ECN_MOD_IP INTO WA_PPETDP_ECN_MOD_IP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PPETDP_ECN_MOD_IP-DURATION_FIX, sy-vline,
WA_PPETDP_ECN_MOD_IP-UNITD, sy-vline,
WA_PPETDP_ECN_MOD_IP-DURRND, sy-vline,
WA_PPETDP_ECN_MOD_IP-VRSIOEX, sy-vline,
WA_PPETDP_ECN_MOD_IP-ACTIVITY, sy-vline,
WA_PPETDP_ECN_MOD_IP-ALTNUM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PPETDP_ECN_MOD_IP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PPETDP_ECN_MOD_IP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PPETDP_ECN_MOD_IP INTO WA_PPETDP_ECN_MOD_IP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPETDP_ECN_MOD_IP-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPETDP_ECN_MOD_IP-AENNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UNITD CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PPETDP_ECN_MOD_IP-UNITD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPETDP_ECN_MOD_IP-UNITD.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field ALTNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPETDP_ECN_MOD_IP-ALTNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPETDP_ECN_MOD_IP-ALTNUM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field NEXT_AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPETDP_ECN_MOD_IP-NEXT_AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPETDP_ECN_MOD_IP-NEXT_AENNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field MODE_UNITD CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PPETDP_ECN_MOD_IP-MODE_UNITD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPETDP_ECN_MOD_IP-MODE_UNITD.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PPETDP_ECN_MOD_IP_STR,
PAGUID TYPE STRING,
AENNR TYPE STRING,
VERSIOID TYPE STRING,
DATEF TYPE STRING,
DURATION TYPE STRING,
DURATION_FIX TYPE STRING,
UNITD TYPE STRING,
DURRND TYPE STRING,
VRSIOEX TYPE STRING,
ACTIVITY TYPE STRING,
ALTNUM TYPE STRING,
AENNR_DATUV TYPE STRING,
NEXT_AENNR TYPE STRING,
NEXT_AENNR_DATUV TYPE STRING,
MODE_DURATION TYPE STRING,
MODE_DURATION_FIX TYPE STRING,
MODE_UNITD TYPE STRING,
VALIDITY TYPE STRING,
VALIDITY_FLAG TYPE STRING,END OF T_EKKO_STR. DATA: WA_PPETDP_ECN_MOD_IP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PPETDP_ECN_MOD_IP_STR-PAGUID sy-vline
WA_PPETDP_ECN_MOD_IP_STR-AENNR sy-vline
WA_PPETDP_ECN_MOD_IP_STR-VERSIOID sy-vline
WA_PPETDP_ECN_MOD_IP_STR-DATEF sy-vline
WA_PPETDP_ECN_MOD_IP_STR-DURATION sy-vline
WA_PPETDP_ECN_MOD_IP_STR-DURATION_FIX sy-vline
WA_PPETDP_ECN_MOD_IP_STR-UNITD sy-vline
WA_PPETDP_ECN_MOD_IP_STR-DURRND sy-vline
WA_PPETDP_ECN_MOD_IP_STR-VRSIOEX sy-vline
WA_PPETDP_ECN_MOD_IP_STR-ACTIVITY sy-vline
WA_PPETDP_ECN_MOD_IP_STR-ALTNUM sy-vline
WA_PPETDP_ECN_MOD_IP_STR-AENNR_DATUV sy-vline
WA_PPETDP_ECN_MOD_IP_STR-NEXT_AENNR sy-vline
WA_PPETDP_ECN_MOD_IP_STR-NEXT_AENNR_DATUV sy-vline
WA_PPETDP_ECN_MOD_IP_STR-MODE_DURATION sy-vline
WA_PPETDP_ECN_MOD_IP_STR-MODE_DURATION_FIX sy-vline
WA_PPETDP_ECN_MOD_IP_STR-MODE_UNITD sy-vline
WA_PPETDP_ECN_MOD_IP_STR-VALIDITY sy-vline
WA_PPETDP_ECN_MOD_IP_STR-VALIDITY_FLAG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.