ABAP Select data from SAP table PPFTCONDTR into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PPFTCONDTR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PPFTCONDTR. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PPFTCONDTR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PPFTCONDTR TYPE STANDARD TABLE OF PPFTCONDTR, WA_PPFTCONDTR TYPE PPFTCONDTR, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <PPFTCONDTR> TYPE PPFTCONDTR. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_PPFTCONDTR. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM PPFTCONDTR INTO TABLE IT_PPFTCONDTR. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM PPFTCONDTR * INTO TABLE @DATA(IT_PPFTCONDTR2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_PPFTCONDTR INDEX 1 INTO DATA(WA_PPFTCONDTR2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_PPFTCONDTR ASSIGNING <PPFTCONDTR>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<PPFTCONDTR>-MANDT = 1.
<PPFTCONDTR>-GUID = 1.
<PPFTCONDTR>-TTYPE = 1.
<PPFTCONDTR>-SELCOND = 1.
<PPFTCONDTR>-SELCONT = 1.
ENDLOOP. LOOP AT IT_PPFTCONDTR INTO WA_PPFTCONDTR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PPFTCONDTR-TEMPL_OID, sy-vline,
WA_PPFTCONDTR-TEMPL_CLS, sy-vline,
WA_PPFTCONDTR-STOP, sy-vline,
WA_PPFTCONDTR-COUNTER, sy-vline,
WA_PPFTCONDTR-OK, sy-vline,
WA_PPFTCONDTR-DETTYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PPFTCONDTR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PPFTCONDTR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PPFTCONDTR INTO WA_PPFTCONDTR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PPFTCONDTR_STR,
MANDT TYPE STRING,
GUID TYPE STRING,
TTYPE TYPE STRING,
SELCOND TYPE STRING,
SELCONT TYPE STRING,
TEMPL_OID TYPE STRING,
TEMPL_CLS TYPE STRING,
STOP TYPE STRING,
COUNTER TYPE STRING,
OK TYPE STRING,
DETTYPE TYPE STRING,
CUSTCONT TYPE STRING,
CUSTCONT2 TYPE STRING,
CONTEXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_PPFTCONDTR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PPFTCONDTR_STR-MANDT sy-vline
WA_PPFTCONDTR_STR-GUID sy-vline
WA_PPFTCONDTR_STR-TTYPE sy-vline
WA_PPFTCONDTR_STR-SELCOND sy-vline
WA_PPFTCONDTR_STR-SELCONT sy-vline
WA_PPFTCONDTR_STR-TEMPL_OID sy-vline
WA_PPFTCONDTR_STR-TEMPL_CLS sy-vline
WA_PPFTCONDTR_STR-STOP sy-vline
WA_PPFTCONDTR_STR-COUNTER sy-vline
WA_PPFTCONDTR_STR-OK sy-vline
WA_PPFTCONDTR_STR-DETTYPE sy-vline
WA_PPFTCONDTR_STR-CUSTCONT sy-vline
WA_PPFTCONDTR_STR-CUSTCONT2 sy-vline
WA_PPFTCONDTR_STR-CONTEXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.