ABAP Select data from SAP table PPSFC_00002737 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PPSFC_00002737 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PPSFC_00002737. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PPSFC_00002737 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PPSFC_00002737 TYPE STANDARD TABLE OF PPSFC_00002737,
      WA_PPSFC_00002737 TYPE PPSFC_00002737,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PPSFC_00002737> TYPE PPSFC_00002737.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PPSFC_00002737.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PPSFC_00002737
  INTO TABLE IT_PPSFC_00002737.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PPSFC_00002737
*  INTO TABLE @DATA(IT_PPSFC_000027372).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PPSFC_00002737 INDEX 1 INTO DATA(WA_PPSFC_000027372).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PPSFC_00002737 ASSIGNING <PPSFC_00002737>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PPSFC_00002737>-VORNR = 1.
<PPSFC_00002737>-PVZNR = 1.
<PPSFC_00002737>-ABLIPKZ = 1.
<PPSFC_00002737>-ABRUE = 1.
<PPSFC_00002737>-ANZZL = 1.
ENDLOOP.

LOOP AT IT_PPSFC_00002737 INTO WA_PPSFC_00002737.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PPSFC_00002737-ARBEH, sy-vline,
WA_PPSFC_00002737-ARBEI, sy-vline,
WA_PPSFC_00002737-ARBID, sy-vline,
WA_PPSFC_00002737-ARUZE, sy-vline,
WA_PPSFC_00002737-AUFAK, sy-vline,
WA_PPSFC_00002737-BEARZ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PPSFC_00002737 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PPSFC_00002737 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PPSFC_00002737 INTO WA_PPSFC_00002737. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit NUMCV, internal->external for field VORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_PPSFC_00002737-VORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPSFC_00002737-VORNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field PVZNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_PPSFC_00002737-PVZNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPSFC_00002737-PVZNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PPSFC_00002737_STR,
VORNR TYPE STRING,
PVZNR TYPE STRING,
ABLIPKZ TYPE STRING,
ABRUE TYPE STRING,
ANZZL TYPE STRING,
ARBEH TYPE STRING,
ARBEI TYPE STRING,
ARBID TYPE STRING,
ARUZE TYPE STRING,
AUFAK TYPE STRING,
BEARZ TYPE STRING,
BEAZE TYPE STRING,
BMSCH TYPE STRING,
CY_SEQNRV TYPE STRING,
DAUNE TYPE STRING,
DAUNO TYPE STRING,
DAUME TYPE STRING,
DAUMI TYPE STRING,
FLIES TYPE STRING,
FSAVD TYPE STRING,
FSAVZ TYPE STRING,
FSEDD TYPE STRING,
FSEDZ TYPE STRING,
FSELD TYPE STRING,
FSELZ TYPE STRING,
FSEVD TYPE STRING,
FSEVZ TYPE STRING,
FSSAD TYPE STRING,
FSSAZ TYPE STRING,
FSSBD TYPE STRING,
FSSBZ TYPE STRING,
FSSLD TYPE STRING,
FSSLZ TYPE STRING,
KALID TYPE STRING,
LAR01 TYPE STRING,
LAR02 TYPE STRING,
LAR03 TYPE STRING,
LAR04 TYPE STRING,
LAR05 TYPE STRING,
LAR06 TYPE STRING,
LIEGZ TYPE STRING,
LIGZE TYPE STRING,
LMNGA TYPE STRING,
LTXA1 TYPE STRING,
MEINH TYPE STRING,
MINWE TYPE STRING,
MGVRG TYPE STRING,
PEINH TYPE STRING,
PREIS TYPE STRING,
PRZNT TYPE STRING,
RASCH TYPE STRING,
RFGRP TYPE STRING,
RFSCH TYPE STRING,
RMNGA TYPE STRING,
RSTZE TYPE STRING,
RUEST TYPE STRING,
SPLIM TYPE STRING,
SPMUS TYPE STRING,
SSAVD TYPE STRING,
SSAVZ TYPE STRING,
SSEDD TYPE STRING,
SSEDZ TYPE STRING,
SSELD TYPE STRING,
SSELZ TYPE STRING,
SSEVD TYPE STRING,
SSEVZ TYPE STRING,
SSSAD TYPE STRING,
SSSAZ TYPE STRING,
SSSBD TYPE STRING,
SSSBZ TYPE STRING,
SSSLD TYPE STRING,
SSSLZ TYPE STRING,
STEUS TYPE STRING,
TRANZ TYPE STRING,
TRAZE TYPE STRING,
UEKAN TYPE STRING,
UEMUS TYPE STRING,
USR04 TYPE STRING,
USR05 TYPE STRING,
USE04 TYPE STRING,
USE05 TYPE STRING,
VGE01 TYPE STRING,
VGE02 TYPE STRING,
VGE03 TYPE STRING,
VGE04 TYPE STRING,
VGE05 TYPE STRING,
VGE06 TYPE STRING,
VGW01 TYPE STRING,
VGW02 TYPE STRING,
VGW03 TYPE STRING,
VGW04 TYPE STRING,
VGW05 TYPE STRING,
VGW06 TYPE STRING,
VGWTS TYPE STRING,
WAERS TYPE STRING,
WARTZ TYPE STRING,
WRTZE TYPE STRING,
XDISP TYPE STRING,
XMNGA TYPE STRING,
ZEILP TYPE STRING,
ZEIMB TYPE STRING,
ZEIMU TYPE STRING,
ZEITN TYPE STRING,
ZEIWM TYPE STRING,
ZEIWN TYPE STRING,
ZLPRO TYPE STRING,
ZMINB TYPE STRING,
ZMINU TYPE STRING,
ZTMIN TYPE STRING,
ZWMIN TYPE STRING,
ZWNOR TYPE STRING,
ISAVD TYPE STRING,
IEAVD TYPE STRING,
ISDD TYPE STRING,
ISDZ TYPE STRING,
IEDD TYPE STRING,
IEDZ TYPE STRING,
ANZMA TYPE STRING,
QUALF TYPE STRING,
LOART TYPE STRING,
LOGRP TYPE STRING,
SAMPLE_SIZE TYPE STRING,
INSPLOT_BASE_UOM TYPE STRING,
ARBPL TYPE STRING,
ME_OPERATION_ID TYPE STRING,
ME_REVISION TYPE STRING,
RUEK TYPE STRING,
ME_RESOURCE_TYPE TYPE STRING,
SAMPLE_SIZE_ALL TYPE STRING,
E1JSTVL TYPE STRING,
E1RESBL TYPE STRING,
E1AFUVL TYPE STRING,
E1KBEDL TYPE STRING,END OF T_EKKO_STR. DATA: WA_PPSFC_00002737_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PPSFC_00002737_STR-VORNR sy-vline
WA_PPSFC_00002737_STR-PVZNR sy-vline
WA_PPSFC_00002737_STR-ABLIPKZ sy-vline
WA_PPSFC_00002737_STR-ABRUE sy-vline
WA_PPSFC_00002737_STR-ANZZL sy-vline
WA_PPSFC_00002737_STR-ARBEH sy-vline
WA_PPSFC_00002737_STR-ARBEI sy-vline
WA_PPSFC_00002737_STR-ARBID sy-vline
WA_PPSFC_00002737_STR-ARUZE sy-vline
WA_PPSFC_00002737_STR-AUFAK sy-vline
WA_PPSFC_00002737_STR-BEARZ sy-vline
WA_PPSFC_00002737_STR-BEAZE sy-vline
WA_PPSFC_00002737_STR-BMSCH sy-vline
WA_PPSFC_00002737_STR-CY_SEQNRV sy-vline
WA_PPSFC_00002737_STR-DAUNE sy-vline
WA_PPSFC_00002737_STR-DAUNO sy-vline
WA_PPSFC_00002737_STR-DAUME sy-vline
WA_PPSFC_00002737_STR-DAUMI sy-vline
WA_PPSFC_00002737_STR-FLIES sy-vline
WA_PPSFC_00002737_STR-FSAVD sy-vline
WA_PPSFC_00002737_STR-FSAVZ sy-vline
WA_PPSFC_00002737_STR-FSEDD sy-vline
WA_PPSFC_00002737_STR-FSEDZ sy-vline
WA_PPSFC_00002737_STR-FSELD sy-vline
WA_PPSFC_00002737_STR-FSELZ sy-vline
WA_PPSFC_00002737_STR-FSEVD sy-vline
WA_PPSFC_00002737_STR-FSEVZ sy-vline
WA_PPSFC_00002737_STR-FSSAD sy-vline
WA_PPSFC_00002737_STR-FSSAZ sy-vline
WA_PPSFC_00002737_STR-FSSBD sy-vline
WA_PPSFC_00002737_STR-FSSBZ sy-vline
WA_PPSFC_00002737_STR-FSSLD sy-vline
WA_PPSFC_00002737_STR-FSSLZ sy-vline
WA_PPSFC_00002737_STR-KALID sy-vline
WA_PPSFC_00002737_STR-LAR01 sy-vline
WA_PPSFC_00002737_STR-LAR02 sy-vline
WA_PPSFC_00002737_STR-LAR03 sy-vline
WA_PPSFC_00002737_STR-LAR04 sy-vline
WA_PPSFC_00002737_STR-LAR05 sy-vline
WA_PPSFC_00002737_STR-LAR06 sy-vline
WA_PPSFC_00002737_STR-LIEGZ sy-vline
WA_PPSFC_00002737_STR-LIGZE sy-vline
WA_PPSFC_00002737_STR-LMNGA sy-vline
WA_PPSFC_00002737_STR-LTXA1 sy-vline
WA_PPSFC_00002737_STR-MEINH sy-vline
WA_PPSFC_00002737_STR-MINWE sy-vline
WA_PPSFC_00002737_STR-MGVRG sy-vline
WA_PPSFC_00002737_STR-PEINH sy-vline
WA_PPSFC_00002737_STR-PREIS sy-vline
WA_PPSFC_00002737_STR-PRZNT sy-vline
WA_PPSFC_00002737_STR-RASCH sy-vline
WA_PPSFC_00002737_STR-RFGRP sy-vline
WA_PPSFC_00002737_STR-RFSCH sy-vline
WA_PPSFC_00002737_STR-RMNGA sy-vline
WA_PPSFC_00002737_STR-RSTZE sy-vline
WA_PPSFC_00002737_STR-RUEST sy-vline
WA_PPSFC_00002737_STR-SPLIM sy-vline
WA_PPSFC_00002737_STR-SPMUS sy-vline
WA_PPSFC_00002737_STR-SSAVD sy-vline
WA_PPSFC_00002737_STR-SSAVZ sy-vline
WA_PPSFC_00002737_STR-SSEDD sy-vline
WA_PPSFC_00002737_STR-SSEDZ sy-vline
WA_PPSFC_00002737_STR-SSELD sy-vline
WA_PPSFC_00002737_STR-SSELZ sy-vline
WA_PPSFC_00002737_STR-SSEVD sy-vline
WA_PPSFC_00002737_STR-SSEVZ sy-vline
WA_PPSFC_00002737_STR-SSSAD sy-vline
WA_PPSFC_00002737_STR-SSSAZ sy-vline
WA_PPSFC_00002737_STR-SSSBD sy-vline
WA_PPSFC_00002737_STR-SSSBZ sy-vline
WA_PPSFC_00002737_STR-SSSLD sy-vline
WA_PPSFC_00002737_STR-SSSLZ sy-vline
WA_PPSFC_00002737_STR-STEUS sy-vline
WA_PPSFC_00002737_STR-TRANZ sy-vline
WA_PPSFC_00002737_STR-TRAZE sy-vline
WA_PPSFC_00002737_STR-UEKAN sy-vline
WA_PPSFC_00002737_STR-UEMUS sy-vline
WA_PPSFC_00002737_STR-USR04 sy-vline
WA_PPSFC_00002737_STR-USR05 sy-vline
WA_PPSFC_00002737_STR-USE04 sy-vline
WA_PPSFC_00002737_STR-USE05 sy-vline
WA_PPSFC_00002737_STR-VGE01 sy-vline
WA_PPSFC_00002737_STR-VGE02 sy-vline
WA_PPSFC_00002737_STR-VGE03 sy-vline
WA_PPSFC_00002737_STR-VGE04 sy-vline
WA_PPSFC_00002737_STR-VGE05 sy-vline
WA_PPSFC_00002737_STR-VGE06 sy-vline
WA_PPSFC_00002737_STR-VGW01 sy-vline
WA_PPSFC_00002737_STR-VGW02 sy-vline
WA_PPSFC_00002737_STR-VGW03 sy-vline
WA_PPSFC_00002737_STR-VGW04 sy-vline
WA_PPSFC_00002737_STR-VGW05 sy-vline
WA_PPSFC_00002737_STR-VGW06 sy-vline
WA_PPSFC_00002737_STR-VGWTS sy-vline
WA_PPSFC_00002737_STR-WAERS sy-vline
WA_PPSFC_00002737_STR-WARTZ sy-vline
WA_PPSFC_00002737_STR-WRTZE sy-vline
WA_PPSFC_00002737_STR-XDISP sy-vline
WA_PPSFC_00002737_STR-XMNGA sy-vline
WA_PPSFC_00002737_STR-ZEILP sy-vline
WA_PPSFC_00002737_STR-ZEIMB sy-vline
WA_PPSFC_00002737_STR-ZEIMU sy-vline
WA_PPSFC_00002737_STR-ZEITN sy-vline
WA_PPSFC_00002737_STR-ZEIWM sy-vline
WA_PPSFC_00002737_STR-ZEIWN sy-vline
WA_PPSFC_00002737_STR-ZLPRO sy-vline
WA_PPSFC_00002737_STR-ZMINB sy-vline
WA_PPSFC_00002737_STR-ZMINU sy-vline
WA_PPSFC_00002737_STR-ZTMIN sy-vline
WA_PPSFC_00002737_STR-ZWMIN sy-vline
WA_PPSFC_00002737_STR-ZWNOR sy-vline
WA_PPSFC_00002737_STR-ISAVD sy-vline
WA_PPSFC_00002737_STR-IEAVD sy-vline
WA_PPSFC_00002737_STR-ISDD sy-vline
WA_PPSFC_00002737_STR-ISDZ sy-vline
WA_PPSFC_00002737_STR-IEDD sy-vline
WA_PPSFC_00002737_STR-IEDZ sy-vline
WA_PPSFC_00002737_STR-ANZMA sy-vline
WA_PPSFC_00002737_STR-QUALF sy-vline
WA_PPSFC_00002737_STR-LOART sy-vline
WA_PPSFC_00002737_STR-LOGRP sy-vline
WA_PPSFC_00002737_STR-SAMPLE_SIZE sy-vline
WA_PPSFC_00002737_STR-INSPLOT_BASE_UOM sy-vline
WA_PPSFC_00002737_STR-ARBPL sy-vline
WA_PPSFC_00002737_STR-ME_OPERATION_ID sy-vline
WA_PPSFC_00002737_STR-ME_REVISION sy-vline
WA_PPSFC_00002737_STR-RUEK sy-vline
WA_PPSFC_00002737_STR-ME_RESOURCE_TYPE sy-vline
WA_PPSFC_00002737_STR-SAMPLE_SIZE_ALL sy-vline
WA_PPSFC_00002737_STR-E1JSTVL sy-vline
WA_PPSFC_00002737_STR-E1RESBL sy-vline
WA_PPSFC_00002737_STR-E1AFUVL sy-vline
WA_PPSFC_00002737_STR-E1KBEDL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.