ABAP Select data from SAP table PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ TYPE STANDARD TABLE OF PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ, WA_PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ TYPE PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ> TYPE PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ INTO TABLE IT_PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ * INTO TABLE @DATA(IT_PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ INDEX 1 INTO DATA(WA_PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ ASSIGNING <PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ>-REF_PERIOD = 1.
<PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ>-TRAIN_AREA = 1.
<PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ>-MODALITY = 1.
<PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ>-INITIATIVE = 1.
<PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ>-DURATION = 1.
ENDLOOP. LOOP AT IT_PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ INTO WA_PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ-TRAIN_SCHEDULE, sy-vline,
WA_PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ-TRAIN_ENTITY_ATTR, sy-vline,
WA_PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ-DIPLOMA, sy-vline,
WA_PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ-QUALIFICATION, sy-vline,
ENDLOOP. *Add any further fields from structure WA_PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ INTO WA_PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ_STR,
REF_PERIOD TYPE STRING,
TRAIN_AREA TYPE STRING,
MODALITY TYPE STRING,
INITIATIVE TYPE STRING,
DURATION TYPE STRING,
TRAIN_SCHEDULE TYPE STRING,
TRAIN_ENTITY_ATTR TYPE STRING,
DIPLOMA TYPE STRING,
QUALIFICATION TYPE STRING,END OF T_EKKO_STR. DATA: WA_PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ_STR-REF_PERIOD sy-vline
WA_PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ_STR-TRAIN_AREA sy-vline
WA_PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ_STR-MODALITY sy-vline
WA_PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ_STR-INITIATIVE sy-vline
WA_PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ_STR-DURATION sy-vline
WA_PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ_STR-TRAIN_SCHEDULE sy-vline
WA_PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ_STR-TRAIN_ENTITY_ATTR sy-vline
WA_PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ_STR-DIPLOMA sy-vline
WA_PPTS_UNIQUE_RP_ANEXO_RFC_TR_AZ_STR-QUALIFICATION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.