ABAP Select data from SAP table PQM_MIC_METH_CAT into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PQM_MIC_METH_CAT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PQM_MIC_METH_CAT. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PQM_MIC_METH_CAT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PQM_MIC_METH_CAT TYPE STANDARD TABLE OF PQM_MIC_METH_CAT, WA_PQM_MIC_METH_CAT TYPE PQM_MIC_METH_CAT, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <PQM_MIC_METH_CAT> TYPE PQM_MIC_METH_CAT. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_PQM_MIC_METH_CAT. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM PQM_MIC_METH_CAT INTO TABLE IT_PQM_MIC_METH_CAT. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM PQM_MIC_METH_CAT * INTO TABLE @DATA(IT_PQM_MIC_METH_CAT2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_PQM_MIC_METH_CAT INDEX 1 INTO DATA(WA_PQM_MIC_METH_CAT2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_PQM_MIC_METH_CAT ASSIGNING <PQM_MIC_METH_CAT>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<PQM_MIC_METH_CAT>-MANDT = 1.
<PQM_MIC_METH_CAT>-INSPECTIONSPECIFICATIONPLANT = 1.
<PQM_MIC_METH_CAT>-INSPECTIONCHARACTERISTIC = 1.
<PQM_MIC_METH_CAT>-INSPECTIONSPECIFICATIONVERSION = 1.
<PQM_MIC_METH_CAT>-INSPECTIONMETHODPLANT = 1.
ENDLOOP. LOOP AT IT_PQM_MIC_METH_CAT INTO WA_PQM_MIC_METH_CAT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PQM_MIC_METH_CAT-INSPECTIONMETHOD, sy-vline,
WA_PQM_MIC_METH_CAT-INSPECTIONMETHODVERSION, sy-vline,
WA_PQM_MIC_METH_CAT-WERKMK, sy-vline,
WA_PQM_MIC_METH_CAT-GUELTIGAB, sy-vline,
WA_PQM_MIC_METH_CAT-ANONR, sy-vline,
WA_PQM_MIC_METH_CAT-KATAB1, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PQM_MIC_METH_CAT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PQM_MIC_METH_CAT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PQM_MIC_METH_CAT INTO WA_PQM_MIC_METH_CAT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field INSPECTIONCHARACTERISTIC CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PQM_MIC_METH_CAT-INSPECTIONCHARACTERISTIC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PQM_MIC_METH_CAT-INSPECTIONCHARACTERISTIC.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field INSPECTIONSPECIFICATIONVERSION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PQM_MIC_METH_CAT-INSPECTIONSPECIFICATIONVERSION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PQM_MIC_METH_CAT-INSPECTIONSPECIFICATIONVERSION.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field INSPECTIONMETHOD CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PQM_MIC_METH_CAT-INSPECTIONMETHOD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PQM_MIC_METH_CAT-INSPECTIONMETHOD.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field INSPECTIONMETHODVERSION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PQM_MIC_METH_CAT-INSPECTIONMETHODVERSION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PQM_MIC_METH_CAT-INSPECTIONMETHODVERSION.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field VERSION1 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PQM_MIC_METH_CAT-VERSION1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PQM_MIC_METH_CAT-VERSION1.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field VERSION2 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PQM_MIC_METH_CAT-VERSION2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PQM_MIC_METH_CAT-VERSION2.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field VERSION3 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PQM_MIC_METH_CAT-VERSION3 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PQM_MIC_METH_CAT-VERSION3.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field VERSION4 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PQM_MIC_METH_CAT-VERSION4 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PQM_MIC_METH_CAT-VERSION4.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field VERSION5 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PQM_MIC_METH_CAT-VERSION5 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PQM_MIC_METH_CAT-VERSION5.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PQM_MIC_METH_CAT_STR,
MANDT TYPE STRING,
INSPECTIONSPECIFICATIONPLANT TYPE STRING,
INSPECTIONCHARACTERISTIC TYPE STRING,
INSPECTIONSPECIFICATIONVERSION TYPE STRING,
INSPECTIONMETHODPLANT TYPE STRING,
INSPECTIONMETHOD TYPE STRING,
INSPECTIONMETHODVERSION TYPE STRING,
WERKMK TYPE STRING,
GUELTIGAB TYPE STRING,
ANONR TYPE STRING,
KATAB1 TYPE STRING,
KATALGART1 TYPE STRING,
AUSWMENGE1 TYPE STRING,
VERSION1 TYPE STRING,
AUSWMGWRK1 TYPE STRING,
KATAB2 TYPE STRING,
KATALGART2 TYPE STRING,
AUSWMENGE2 TYPE STRING,
VERSION2 TYPE STRING,
AUSWMGWRK2 TYPE STRING,
KATAB3 TYPE STRING,
KATALGART3 TYPE STRING,
AUSWMENGE3 TYPE STRING,
VERSION3 TYPE STRING,
AUSWMGWRK3 TYPE STRING,
KATAB4 TYPE STRING,
KATALGART4 TYPE STRING,
AUSWMENGE4 TYPE STRING,
VERSION4 TYPE STRING,
AUSWMGWRK4 TYPE STRING,
KATAB5 TYPE STRING,
KATALGART5 TYPE STRING,
AUSWMENGE5 TYPE STRING,
VERSION5 TYPE STRING,
AUSWMGWRK5 TYPE STRING,END OF T_EKKO_STR. DATA: WA_PQM_MIC_METH_CAT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PQM_MIC_METH_CAT_STR-MANDT sy-vline
WA_PQM_MIC_METH_CAT_STR-INSPECTIONSPECIFICATIONPLANT sy-vline
WA_PQM_MIC_METH_CAT_STR-INSPECTIONCHARACTERISTIC sy-vline
WA_PQM_MIC_METH_CAT_STR-INSPECTIONSPECIFICATIONVERSION sy-vline
WA_PQM_MIC_METH_CAT_STR-INSPECTIONMETHODPLANT sy-vline
WA_PQM_MIC_METH_CAT_STR-INSPECTIONMETHOD sy-vline
WA_PQM_MIC_METH_CAT_STR-INSPECTIONMETHODVERSION sy-vline
WA_PQM_MIC_METH_CAT_STR-WERKMK sy-vline
WA_PQM_MIC_METH_CAT_STR-GUELTIGAB sy-vline
WA_PQM_MIC_METH_CAT_STR-ANONR sy-vline
WA_PQM_MIC_METH_CAT_STR-KATAB1 sy-vline
WA_PQM_MIC_METH_CAT_STR-KATALGART1 sy-vline
WA_PQM_MIC_METH_CAT_STR-AUSWMENGE1 sy-vline
WA_PQM_MIC_METH_CAT_STR-VERSION1 sy-vline
WA_PQM_MIC_METH_CAT_STR-AUSWMGWRK1 sy-vline
WA_PQM_MIC_METH_CAT_STR-KATAB2 sy-vline
WA_PQM_MIC_METH_CAT_STR-KATALGART2 sy-vline
WA_PQM_MIC_METH_CAT_STR-AUSWMENGE2 sy-vline
WA_PQM_MIC_METH_CAT_STR-VERSION2 sy-vline
WA_PQM_MIC_METH_CAT_STR-AUSWMGWRK2 sy-vline
WA_PQM_MIC_METH_CAT_STR-KATAB3 sy-vline
WA_PQM_MIC_METH_CAT_STR-KATALGART3 sy-vline
WA_PQM_MIC_METH_CAT_STR-AUSWMENGE3 sy-vline
WA_PQM_MIC_METH_CAT_STR-VERSION3 sy-vline
WA_PQM_MIC_METH_CAT_STR-AUSWMGWRK3 sy-vline
WA_PQM_MIC_METH_CAT_STR-KATAB4 sy-vline
WA_PQM_MIC_METH_CAT_STR-KATALGART4 sy-vline
WA_PQM_MIC_METH_CAT_STR-AUSWMENGE4 sy-vline
WA_PQM_MIC_METH_CAT_STR-VERSION4 sy-vline
WA_PQM_MIC_METH_CAT_STR-AUSWMGWRK4 sy-vline
WA_PQM_MIC_METH_CAT_STR-KATAB5 sy-vline
WA_PQM_MIC_METH_CAT_STR-KATALGART5 sy-vline
WA_PQM_MIC_METH_CAT_STR-AUSWMENGE5 sy-vline
WA_PQM_MIC_METH_CAT_STR-VERSION5 sy-vline
WA_PQM_MIC_METH_CAT_STR-AUSWMGWRK5 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.