ABAP Select data from SAP table PROE2 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PROE2 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PROE2. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PROE2 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PROE2 TYPE STANDARD TABLE OF PROE2,
      WA_PROE2 TYPE PROE2,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PROE2> TYPE PROE2.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PROE2.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PROE2
  INTO TABLE IT_PROE2.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PROE2
*  INTO TABLE @DATA(IT_PROE22).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PROE2 INDEX 1 INTO DATA(WA_PROE22).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PROE2 ASSIGNING <PROE2>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PROE2>-PERNR = 1.
<PROE2>-RECTY = 1.
<PROE2>-PERIOD = 1.
<PROE2>-SEQNR = 1.
<PROE2>-ABKRS = 1.
ENDLOOP.

LOOP AT IT_PROE2 INTO WA_PROE2.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PROE2-FPPER, sy-vline,
WA_PROE2-FPBEG, sy-vline,
WA_PROE2-FPEND, sy-vline,
WA_PROE2-IABKRS, sy-vline,
WA_PROE2-IPERM, sy-vline,
WA_PROE2-INPER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PROE2 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PROE2 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PROE2 INTO WA_PROE2. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PROE2_STR,
PERNR TYPE STRING,
RECTY TYPE STRING,
PERIOD TYPE STRING,
SEQNR TYPE STRING,
ABKRS TYPE STRING,
FPPER TYPE STRING,
FPBEG TYPE STRING,
FPEND TYPE STRING,
IABKRS TYPE STRING,
IPERM TYPE STRING,
INPER TYPE STRING,
IPEND TYPE STRING,
JUPER TYPE STRING,
SRTZA TYPE STRING,
PAYTY TYPE STRING,
PAYID TYPE STRING,
VOID TYPE STRING,
BONDT TYPE STRING,
RUNDT TYPE STRING,
RUNTM TYPE STRING,
PERMO TYPE STRING,
VOIDD TYPE STRING,
VOIDT TYPE STRING,
VOIDR TYPE STRING,
PAYDT TYPE STRING,
DUMMY TYPE STRING,
INPTY TYPE STRING,
INPID TYPE STRING,
OCRSN TYPE STRING,
INOCR TYPE STRING,
OCCAT TYPE STRING,
INOCC TYPE STRING,
REVERSAL TYPE STRING,
OUTOFSEQ TYPE STRING,
OOSDATE TYPE STRING,
ARC_GROUP TYPE STRING,
CALCD TYPE STRING,
PERSON TYPE STRING,
PERSDATA TYPE STRING,
BRACKET TYPE STRING,
ORIG_SRTZA TYPE STRING,END OF T_EKKO_STR. DATA: WA_PROE2_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PROE2_STR-PERNR sy-vline
WA_PROE2_STR-RECTY sy-vline
WA_PROE2_STR-PERIOD sy-vline
WA_PROE2_STR-SEQNR sy-vline
WA_PROE2_STR-ABKRS sy-vline
WA_PROE2_STR-FPPER sy-vline
WA_PROE2_STR-FPBEG sy-vline
WA_PROE2_STR-FPEND sy-vline
WA_PROE2_STR-IABKRS sy-vline
WA_PROE2_STR-IPERM sy-vline
WA_PROE2_STR-INPER sy-vline
WA_PROE2_STR-IPEND sy-vline
WA_PROE2_STR-JUPER sy-vline
WA_PROE2_STR-SRTZA sy-vline
WA_PROE2_STR-PAYTY sy-vline
WA_PROE2_STR-PAYID sy-vline
WA_PROE2_STR-VOID sy-vline
WA_PROE2_STR-BONDT sy-vline
WA_PROE2_STR-RUNDT sy-vline
WA_PROE2_STR-RUNTM sy-vline
WA_PROE2_STR-PERMO sy-vline
WA_PROE2_STR-VOIDD sy-vline
WA_PROE2_STR-VOIDT sy-vline
WA_PROE2_STR-VOIDR sy-vline
WA_PROE2_STR-PAYDT sy-vline
WA_PROE2_STR-DUMMY sy-vline
WA_PROE2_STR-INPTY sy-vline
WA_PROE2_STR-INPID sy-vline
WA_PROE2_STR-OCRSN sy-vline
WA_PROE2_STR-INOCR sy-vline
WA_PROE2_STR-OCCAT sy-vline
WA_PROE2_STR-INOCC sy-vline
WA_PROE2_STR-REVERSAL sy-vline
WA_PROE2_STR-OUTOFSEQ sy-vline
WA_PROE2_STR-OOSDATE sy-vline
WA_PROE2_STR-ARC_GROUP sy-vline
WA_PROE2_STR-CALCD sy-vline
WA_PROE2_STR-PERSON sy-vline
WA_PROE2_STR-PERSDATA sy-vline
WA_PROE2_STR-BRACKET sy-vline
WA_PROE2_STR-ORIG_SRTZA sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.