ABAP Select data from SAP table PRP_TS_EXT_REQ_PROFILE into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PRP_TS_EXT_REQ_PROFILE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PRP_TS_EXT_REQ_PROFILE. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PRP_TS_EXT_REQ_PROFILE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PRP_TS_EXT_REQ_PROFILE TYPE STANDARD TABLE OF PRP_TS_EXT_REQ_PROFILE, WA_PRP_TS_EXT_REQ_PROFILE TYPE PRP_TS_EXT_REQ_PROFILE, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <PRP_TS_EXT_REQ_PROFILE> TYPE PRP_TS_EXT_REQ_PROFILE. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_PRP_TS_EXT_REQ_PROFILE. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM PRP_TS_EXT_REQ_PROFILE INTO TABLE IT_PRP_TS_EXT_REQ_PROFILE. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM PRP_TS_EXT_REQ_PROFILE * INTO TABLE @DATA(IT_PRP_TS_EXT_REQ_PROFILE2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_PRP_TS_EXT_REQ_PROFILE INDEX 1 INTO DATA(WA_PRP_TS_EXT_REQ_PROFILE2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_PRP_TS_EXT_REQ_PROFILE ASSIGNING <PRP_TS_EXT_REQ_PROFILE>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<PRP_TS_EXT_REQ_PROFILE>-INTERVALS = 1.
<PRP_TS_EXT_REQ_PROFILE>-TIMESPECS = 1.
<PRP_TS_EXT_REQ_PROFILE>-SCRULE_DATA = 1.
<PRP_TS_EXT_REQ_PROFILE>-TAB_RO = 1.
<PRP_TS_EXT_REQ_PROFILE>-TAB_RN = 1.
ENDLOOP. LOOP AT IT_PRP_TS_EXT_REQ_PROFILE INTO WA_PRP_TS_EXT_REQ_PROFILE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PRP_TS_EXT_REQ_PROFILE-TAB_D, sy-vline,
WA_PRP_TS_EXT_REQ_PROFILE-TAB_W, sy-vline,
WA_PRP_TS_EXT_REQ_PROFILE-TAB_M1, sy-vline,
WA_PRP_TS_EXT_REQ_PROFILE-TAB_M3, sy-vline,
WA_PRP_TS_EXT_REQ_PROFILE-TAB_T, sy-vline,
WA_PRP_TS_EXT_REQ_PROFILE-REQ_QUALIS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PRP_TS_EXT_REQ_PROFILE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PRP_TS_EXT_REQ_PROFILE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PRP_TS_EXT_REQ_PROFILE INTO WA_PRP_TS_EXT_REQ_PROFILE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field ADDR_NUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PRP_TS_EXT_REQ_PROFILE-ADDR_NUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PRP_TS_EXT_REQ_PROFILE-ADDR_NUM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PRP_TS_EXT_REQ_PROFILE_STR,
INTERVALS TYPE STRING,
TIMESPECS TYPE STRING,
SCRULE_DATA TYPE STRING,
TAB_RO TYPE STRING,
TAB_RN TYPE STRING,
TAB_D TYPE STRING,
TAB_W TYPE STRING,
TAB_M1 TYPE STRING,
TAB_M3 TYPE STRING,
TAB_T TYPE STRING,
REQ_QUALIS TYPE STRING,
RESOURCES TYPE STRING,
RES_TYPES TYPE STRING,
LOCATION TYPE STRING,
ADDR_NUM TYPE STRING,
ADDRESS_ID TYPE STRING,
LATITUDE TYPE STRING,
LONGITUDE TYPE STRING,
PRECISID TYPE STRING,END OF T_EKKO_STR. DATA: WA_PRP_TS_EXT_REQ_PROFILE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PRP_TS_EXT_REQ_PROFILE_STR-INTERVALS sy-vline
WA_PRP_TS_EXT_REQ_PROFILE_STR-TIMESPECS sy-vline
WA_PRP_TS_EXT_REQ_PROFILE_STR-SCRULE_DATA sy-vline
WA_PRP_TS_EXT_REQ_PROFILE_STR-TAB_RO sy-vline
WA_PRP_TS_EXT_REQ_PROFILE_STR-TAB_RN sy-vline
WA_PRP_TS_EXT_REQ_PROFILE_STR-TAB_D sy-vline
WA_PRP_TS_EXT_REQ_PROFILE_STR-TAB_W sy-vline
WA_PRP_TS_EXT_REQ_PROFILE_STR-TAB_M1 sy-vline
WA_PRP_TS_EXT_REQ_PROFILE_STR-TAB_M3 sy-vline
WA_PRP_TS_EXT_REQ_PROFILE_STR-TAB_T sy-vline
WA_PRP_TS_EXT_REQ_PROFILE_STR-REQ_QUALIS sy-vline
WA_PRP_TS_EXT_REQ_PROFILE_STR-RESOURCES sy-vline
WA_PRP_TS_EXT_REQ_PROFILE_STR-RES_TYPES sy-vline
WA_PRP_TS_EXT_REQ_PROFILE_STR-LOCATION sy-vline
WA_PRP_TS_EXT_REQ_PROFILE_STR-ADDR_NUM sy-vline
WA_PRP_TS_EXT_REQ_PROFILE_STR-ADDRESS_ID sy-vline
WA_PRP_TS_EXT_REQ_PROFILE_STR-LATITUDE sy-vline
WA_PRP_TS_EXT_REQ_PROFILE_STR-LONGITUDE sy-vline
WA_PRP_TS_EXT_REQ_PROFILE_STR-PRECISID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.