ABAP Select data from SAP table PS0784 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PS0784 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PS0784. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PS0784 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PS0784 TYPE STANDARD TABLE OF PS0784,
      WA_PS0784 TYPE PS0784,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PS0784> TYPE PS0784.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PS0784.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PS0784
  INTO TABLE IT_PS0784.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PS0784
*  INTO TABLE @DATA(IT_PS07842).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PS0784 INDEX 1 INTO DATA(WA_PS07842).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PS0784 ASSIGNING <PS0784>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PS0784>-DATUM_EHE_VON = 1.
<PS0784>-DATUM_EHE_BIS = 1.
<PS0784>-DATUM_VB_EHE_VON = 1.
<PS0784>-DATUM_VB_EHE_BIS = 1.
<PS0784>-GERICHT = 1.
ENDLOOP.

LOOP AT IT_PS0784 INTO WA_PS0784.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PS0784-ADRNR_GERICHT, sy-vline,
WA_PS0784-AKTENZ_VERS_AUSG, sy-vline,
WA_PS0784-ANTRAGSTELLER, sy-vline,
WA_PS0784-APRFNR, sy-vline,
WA_PS0784-ABW_MAX_RGVH, sy-vline,
WA_PS0784-ABW_SZAHLUNG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PS0784 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PS0784 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PS0784 INTO WA_PS0784. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field ADRNR_GERICHT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PS0784-ADRNR_GERICHT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PS0784-ADRNR_GERICHT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PS0784_STR,
DATUM_EHE_VON TYPE STRING,
DATUM_EHE_BIS TYPE STRING,
DATUM_VB_EHE_VON TYPE STRING,
DATUM_VB_EHE_BIS TYPE STRING,
GERICHT TYPE STRING,
ADRNR_GERICHT TYPE STRING,
AKTENZ_VERS_AUSG TYPE STRING,
ANTRAGSTELLER TYPE STRING,
APRFNR TYPE STRING,
ABW_MAX_RGVH TYPE STRING,
ABW_SZAHLUNG TYPE STRING,
ABW_SZAHLUNG_WA TYPE STRING,
BOX_ABW_SZAHLUNG TYPE STRING,
BDATE TYPE STRING,END OF T_EKKO_STR. DATA: WA_PS0784_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PS0784_STR-DATUM_EHE_VON sy-vline
WA_PS0784_STR-DATUM_EHE_BIS sy-vline
WA_PS0784_STR-DATUM_VB_EHE_VON sy-vline
WA_PS0784_STR-DATUM_VB_EHE_BIS sy-vline
WA_PS0784_STR-GERICHT sy-vline
WA_PS0784_STR-ADRNR_GERICHT sy-vline
WA_PS0784_STR-AKTENZ_VERS_AUSG sy-vline
WA_PS0784_STR-ANTRAGSTELLER sy-vline
WA_PS0784_STR-APRFNR sy-vline
WA_PS0784_STR-ABW_MAX_RGVH sy-vline
WA_PS0784_STR-ABW_SZAHLUNG sy-vline
WA_PS0784_STR-ABW_SZAHLUNG_WA sy-vline
WA_PS0784_STR-BOX_ABW_SZAHLUNG sy-vline
WA_PS0784_STR-BDATE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.