ABAP Select data from SAP table PS0889 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PS0889 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PS0889. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PS0889 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PS0889 TYPE STANDARD TABLE OF PS0889, WA_PS0889 TYPE PS0889, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <PS0889> TYPE PS0889. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_PS0889. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM PS0889 INTO TABLE IT_PS0889. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM PS0889 * INTO TABLE @DATA(IT_PS08892). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_PS0889 INDEX 1 INTO DATA(WA_PS08892). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_PS0889 ASSIGNING <PS0889>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<PS0889>-RET_BEN_PLN = 1.
<PS0889>-RET_BEN_PLN_TYP = 1.
<PS0889>-PART_STAT = 1.
<PS0889>-ENRL_STAT = 1.
<PS0889>-PS_CHG_RSN = 1.
ENDLOOP. LOOP AT IT_PS0889 INTO WA_PS0889. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PS0889-COM_STA_DTE, sy-vline,
WA_PS0889-EXC_YR, sy-vline,
WA_PS0889-EXC_MON, sy-vline,
WA_PS0889-PART_NUM, sy-vline,
WA_PS0889-CTRB_STAT_ER, sy-vline,
WA_PS0889-CTRB_STAT_PART, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PS0889 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PS0889 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PS0889 INTO WA_PS0889. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PS0889_STR,
RET_BEN_PLN TYPE STRING,
RET_BEN_PLN_TYP TYPE STRING,
PART_STAT TYPE STRING,
ENRL_STAT TYPE STRING,
PS_CHG_RSN TYPE STRING,
COM_STA_DTE TYPE STRING,
EXC_YR TYPE STRING,
EXC_MON TYPE STRING,
PART_NUM TYPE STRING,
CTRB_STAT_ER TYPE STRING,
CTRB_STAT_PART TYPE STRING,
EE_CONT_REJ TYPE STRING,
STD_PAYT_AMT TYPE STRING,
STD_PREM_AMT_ER TYPE STRING,
STD_PREM_AMT_EE TYPE STRING,
SPC_PREM_AMT_ER TYPE STRING,
SPC_PREM_AMT_EE TYPE STRING,
ADM_PREM_AMT_ER TYPE STRING,
ADM_PREM_AMT_EE TYPE STRING,
ER_CS_IND TYPE STRING,
PART_CS_IND TYPE STRING,
CTRB_SUSP_RSN TYPE STRING,
SUB_PLAN1 TYPE STRING,
SUB_PLAN2 TYPE STRING,
SUB_PLAN3 TYPE STRING,
SUB_PLAN4 TYPE STRING,
SUB_PLAN5 TYPE STRING,
STD_PAYT_AMT1 TYPE STRING,
STD_PAYT_AMT2 TYPE STRING,
STD_PAYT_AMT3 TYPE STRING,
STD_PAYT_AMT4 TYPE STRING,
STD_PAYT_AMT5 TYPE STRING,
STD_PREM_AMT_ER1 TYPE STRING,
STD_PREM_AMT_EE1 TYPE STRING,
SPC_PREM_AMT_ER1 TYPE STRING,
SPC_PREM_AMT_EE1 TYPE STRING,
ADM_PREM_AMT_ER1 TYPE STRING,
ADM_PREM_AMT_EE1 TYPE STRING,
STD_PREM_AMT_ER2 TYPE STRING,
STD_PREM_AMT_EE2 TYPE STRING,
SPC_PREM_AMT_ER2 TYPE STRING,
SPC_PREM_AMT_EE2 TYPE STRING,
ADM_PREM_AMT_ER2 TYPE STRING,
ADM_PREM_AMT_EE2 TYPE STRING,
STD_PREM_AMT_ER3 TYPE STRING,
STD_PREM_AMT_EE3 TYPE STRING,
SPC_PREM_AMT_ER3 TYPE STRING,
SPC_PREM_AMT_EE3 TYPE STRING,
ADM_PREM_AMT_ER3 TYPE STRING,
ADM_PREM_AMT_EE3 TYPE STRING,
STD_PREM_AMT_ER4 TYPE STRING,
STD_PREM_AMT_EE4 TYPE STRING,
SPC_PREM_AMT_ER4 TYPE STRING,
SPC_PREM_AMT_EE4 TYPE STRING,
ADM_PREM_AMT_ER4 TYPE STRING,
ADM_PREM_AMT_EE4 TYPE STRING,
STD_PREM_AMT_ER5 TYPE STRING,
STD_PREM_AMT_EE5 TYPE STRING,
SPC_PREM_AMT_ER5 TYPE STRING,
SPC_PREM_AMT_EE5 TYPE STRING,
ADM_PREM_AMT_ER5 TYPE STRING,
ADM_PREM_AMT_EE5 TYPE STRING,
WAERS TYPE STRING,
BEN_TYP TYPE STRING,
PEN_ELG_STAT TYPE STRING,
BEN_RECE_STAT TYPE STRING,
PAYT_TYP TYPE STRING,
PAYT_PER TYPE STRING,
BEN_TYP1 TYPE STRING,
PEN_ELG_STAT1 TYPE STRING,
BEN_RECE_STAT1 TYPE STRING,
PAYT_TYP1 TYPE STRING,
PAYT_PER1 TYPE STRING,
BEN_TYP2 TYPE STRING,
PEN_ELG_STAT2 TYPE STRING,
BEN_RECE_STAT2 TYPE STRING,
PAYT_TYP2 TYPE STRING,
PAYT_PER2 TYPE STRING,
BEN_TYP3 TYPE STRING,
PEN_ELG_STAT3 TYPE STRING,
BEN_RECE_STAT3 TYPE STRING,
PAYT_TYP3 TYPE STRING,
PAYT_PER3 TYPE STRING,
BEN_TYP4 TYPE STRING,
PEN_ELG_STAT4 TYPE STRING,
BEN_RECE_STAT4 TYPE STRING,
PAYT_TYP4 TYPE STRING,
PAYT_PER4 TYPE STRING,
BEN_TYP5 TYPE STRING,
PEN_ELG_STAT5 TYPE STRING,
BEN_RECE_STAT5 TYPE STRING,
PAYT_TYP5 TYPE STRING,
PAYT_PER5 TYPE STRING,END OF T_EKKO_STR. DATA: WA_PS0889_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PS0889_STR-RET_BEN_PLN sy-vline
WA_PS0889_STR-RET_BEN_PLN_TYP sy-vline
WA_PS0889_STR-PART_STAT sy-vline
WA_PS0889_STR-ENRL_STAT sy-vline
WA_PS0889_STR-PS_CHG_RSN sy-vline
WA_PS0889_STR-COM_STA_DTE sy-vline
WA_PS0889_STR-EXC_YR sy-vline
WA_PS0889_STR-EXC_MON sy-vline
WA_PS0889_STR-PART_NUM sy-vline
WA_PS0889_STR-CTRB_STAT_ER sy-vline
WA_PS0889_STR-CTRB_STAT_PART sy-vline
WA_PS0889_STR-EE_CONT_REJ sy-vline
WA_PS0889_STR-STD_PAYT_AMT sy-vline
WA_PS0889_STR-STD_PREM_AMT_ER sy-vline
WA_PS0889_STR-STD_PREM_AMT_EE sy-vline
WA_PS0889_STR-SPC_PREM_AMT_ER sy-vline
WA_PS0889_STR-SPC_PREM_AMT_EE sy-vline
WA_PS0889_STR-ADM_PREM_AMT_ER sy-vline
WA_PS0889_STR-ADM_PREM_AMT_EE sy-vline
WA_PS0889_STR-ER_CS_IND sy-vline
WA_PS0889_STR-PART_CS_IND sy-vline
WA_PS0889_STR-CTRB_SUSP_RSN sy-vline
WA_PS0889_STR-SUB_PLAN1 sy-vline
WA_PS0889_STR-SUB_PLAN2 sy-vline
WA_PS0889_STR-SUB_PLAN3 sy-vline
WA_PS0889_STR-SUB_PLAN4 sy-vline
WA_PS0889_STR-SUB_PLAN5 sy-vline
WA_PS0889_STR-STD_PAYT_AMT1 sy-vline
WA_PS0889_STR-STD_PAYT_AMT2 sy-vline
WA_PS0889_STR-STD_PAYT_AMT3 sy-vline
WA_PS0889_STR-STD_PAYT_AMT4 sy-vline
WA_PS0889_STR-STD_PAYT_AMT5 sy-vline
WA_PS0889_STR-STD_PREM_AMT_ER1 sy-vline
WA_PS0889_STR-STD_PREM_AMT_EE1 sy-vline
WA_PS0889_STR-SPC_PREM_AMT_ER1 sy-vline
WA_PS0889_STR-SPC_PREM_AMT_EE1 sy-vline
WA_PS0889_STR-ADM_PREM_AMT_ER1 sy-vline
WA_PS0889_STR-ADM_PREM_AMT_EE1 sy-vline
WA_PS0889_STR-STD_PREM_AMT_ER2 sy-vline
WA_PS0889_STR-STD_PREM_AMT_EE2 sy-vline
WA_PS0889_STR-SPC_PREM_AMT_ER2 sy-vline
WA_PS0889_STR-SPC_PREM_AMT_EE2 sy-vline
WA_PS0889_STR-ADM_PREM_AMT_ER2 sy-vline
WA_PS0889_STR-ADM_PREM_AMT_EE2 sy-vline
WA_PS0889_STR-STD_PREM_AMT_ER3 sy-vline
WA_PS0889_STR-STD_PREM_AMT_EE3 sy-vline
WA_PS0889_STR-SPC_PREM_AMT_ER3 sy-vline
WA_PS0889_STR-SPC_PREM_AMT_EE3 sy-vline
WA_PS0889_STR-ADM_PREM_AMT_ER3 sy-vline
WA_PS0889_STR-ADM_PREM_AMT_EE3 sy-vline
WA_PS0889_STR-STD_PREM_AMT_ER4 sy-vline
WA_PS0889_STR-STD_PREM_AMT_EE4 sy-vline
WA_PS0889_STR-SPC_PREM_AMT_ER4 sy-vline
WA_PS0889_STR-SPC_PREM_AMT_EE4 sy-vline
WA_PS0889_STR-ADM_PREM_AMT_ER4 sy-vline
WA_PS0889_STR-ADM_PREM_AMT_EE4 sy-vline
WA_PS0889_STR-STD_PREM_AMT_ER5 sy-vline
WA_PS0889_STR-STD_PREM_AMT_EE5 sy-vline
WA_PS0889_STR-SPC_PREM_AMT_ER5 sy-vline
WA_PS0889_STR-SPC_PREM_AMT_EE5 sy-vline
WA_PS0889_STR-ADM_PREM_AMT_ER5 sy-vline
WA_PS0889_STR-ADM_PREM_AMT_EE5 sy-vline
WA_PS0889_STR-WAERS sy-vline
WA_PS0889_STR-BEN_TYP sy-vline
WA_PS0889_STR-PEN_ELG_STAT sy-vline
WA_PS0889_STR-BEN_RECE_STAT sy-vline
WA_PS0889_STR-PAYT_TYP sy-vline
WA_PS0889_STR-PAYT_PER sy-vline
WA_PS0889_STR-BEN_TYP1 sy-vline
WA_PS0889_STR-PEN_ELG_STAT1 sy-vline
WA_PS0889_STR-BEN_RECE_STAT1 sy-vline
WA_PS0889_STR-PAYT_TYP1 sy-vline
WA_PS0889_STR-PAYT_PER1 sy-vline
WA_PS0889_STR-BEN_TYP2 sy-vline
WA_PS0889_STR-PEN_ELG_STAT2 sy-vline
WA_PS0889_STR-BEN_RECE_STAT2 sy-vline
WA_PS0889_STR-PAYT_TYP2 sy-vline
WA_PS0889_STR-PAYT_PER2 sy-vline
WA_PS0889_STR-BEN_TYP3 sy-vline
WA_PS0889_STR-PEN_ELG_STAT3 sy-vline
WA_PS0889_STR-BEN_RECE_STAT3 sy-vline
WA_PS0889_STR-PAYT_TYP3 sy-vline
WA_PS0889_STR-PAYT_PER3 sy-vline
WA_PS0889_STR-BEN_TYP4 sy-vline
WA_PS0889_STR-PEN_ELG_STAT4 sy-vline
WA_PS0889_STR-BEN_RECE_STAT4 sy-vline
WA_PS0889_STR-PAYT_TYP4 sy-vline
WA_PS0889_STR-PAYT_PER4 sy-vline
WA_PS0889_STR-BEN_TYP5 sy-vline
WA_PS0889_STR-PEN_ELG_STAT5 sy-vline
WA_PS0889_STR-BEN_RECE_STAT5 sy-vline
WA_PS0889_STR-PAYT_TYP5 sy-vline
WA_PS0889_STR-PAYT_PER5 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.