ABAP Select data from SAP table PTRV_UTIL_ABZUG into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PTRV_UTIL_ABZUG table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PTRV_UTIL_ABZUG. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PTRV_UTIL_ABZUG table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PTRV_UTIL_ABZUG TYPE STANDARD TABLE OF PTRV_UTIL_ABZUG,
      WA_PTRV_UTIL_ABZUG TYPE PTRV_UTIL_ABZUG,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PTRV_UTIL_ABZUG> TYPE PTRV_UTIL_ABZUG.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PTRV_UTIL_ABZUG.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PTRV_UTIL_ABZUG
  INTO TABLE IT_PTRV_UTIL_ABZUG.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PTRV_UTIL_ABZUG
*  INTO TABLE @DATA(IT_PTRV_UTIL_ABZUG2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PTRV_UTIL_ABZUG INDEX 1 INTO DATA(WA_PTRV_UTIL_ABZUG2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PTRV_UTIL_ABZUG ASSIGNING <PTRV_UTIL_ABZUG>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PTRV_UTIL_ABZUG>-ABDAT = 1.
<PTRV_UTIL_ABZUG>-FRSTK = 1.
<PTRV_UTIL_ABZUG>-MITAG = 1.
<PTRV_UTIL_ABZUG>-ABEND = 1.
<PTRV_UTIL_ABZUG>-ESBON = 1.
ENDLOOP.

LOOP AT IT_PTRV_UTIL_ABZUG INTO WA_PTRV_UTIL_ABZUG.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PTRV_UTIL_ABZUG-ZIKEY, sy-vline,
WA_PTRV_UTIL_ABZUG-UEBERN, sy-vline,
WA_PTRV_UTIL_ABZUG-BRFT_TIME, sy-vline,
WA_PTRV_UTIL_ABZUG-LNCH_TIME, sy-vline,
WA_PTRV_UTIL_ABZUG-DINN_TIME, sy-vline,
WA_PTRV_UTIL_ABZUG-VERPF, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PTRV_UTIL_ABZUG you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PTRV_UTIL_ABZUG TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PTRV_UTIL_ABZUG INTO WA_PTRV_UTIL_ABZUG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PTRV_UTIL_ABZUG_STR,
ABDAT TYPE STRING,
FRSTK TYPE STRING,
MITAG TYPE STRING,
ABEND TYPE STRING,
ESBON TYPE STRING,
ZIKEY TYPE STRING,
UEBERN TYPE STRING,
BRFT_TIME TYPE STRING,
LNCH_TIME TYPE STRING,
DINN_TIME TYPE STRING,
VERPF TYPE STRING,
UEBERNACHT TYPE STRING,
SB_FRSTK TYPE STRING,
SB_MITAG TYPE STRING,
SB_ABEND TYPE STRING,
BRFT_REC_NO TYPE STRING,
LNCH_REC_NO TYPE STRING,
DINN_REC_NO TYPE STRING,
NGHT_TIME TYPE STRING,
VISIBLEBRE TYPE STRING,
INPUTBRE TYPE STRING,
REQUIREDBRE TYPE STRING,
VISIBLEBRT TYPE STRING,
INPUTBRT TYPE STRING,
REQUIREDBRT TYPE STRING,
VISIBLELNC TYPE STRING,
INPUTLNC TYPE STRING,
REQUIREDLNC TYPE STRING,
VISIBLELNT TYPE STRING,
INPUTLNT TYPE STRING,
REQUIREDLNT TYPE STRING,
VISIBLEDIN TYPE STRING,
INPUTDIN TYPE STRING,
REQUIREDDIN TYPE STRING,
VISIBLEDIT TYPE STRING,
INPUTDIT TYPE STRING,
REQUIREDDIT TYPE STRING,
VISIBLENGT TYPE STRING,
INPUTNGT TYPE STRING,
REQUIREDNGT TYPE STRING,
VISIBLECUP TYPE STRING,
INPUTCUP TYPE STRING,
REQUIREDCUP TYPE STRING,
DISPLAY_ONLY TYPE STRING,
VISIBLEFSB TYPE STRING,
INPUTFSB TYPE STRING,
REQUIREDFSB TYPE STRING,
VISIBLEMSB TYPE STRING,
INPUTMSB TYPE STRING,
REQUIREDMSB TYPE STRING,
VISIBLEASB TYPE STRING,
INPUTASB TYPE STRING,
REQUIREDASB TYPE STRING,END OF T_EKKO_STR. DATA: WA_PTRV_UTIL_ABZUG_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PTRV_UTIL_ABZUG_STR-ABDAT sy-vline
WA_PTRV_UTIL_ABZUG_STR-FRSTK sy-vline
WA_PTRV_UTIL_ABZUG_STR-MITAG sy-vline
WA_PTRV_UTIL_ABZUG_STR-ABEND sy-vline
WA_PTRV_UTIL_ABZUG_STR-ESBON sy-vline
WA_PTRV_UTIL_ABZUG_STR-ZIKEY sy-vline
WA_PTRV_UTIL_ABZUG_STR-UEBERN sy-vline
WA_PTRV_UTIL_ABZUG_STR-BRFT_TIME sy-vline
WA_PTRV_UTIL_ABZUG_STR-LNCH_TIME sy-vline
WA_PTRV_UTIL_ABZUG_STR-DINN_TIME sy-vline
WA_PTRV_UTIL_ABZUG_STR-VERPF sy-vline
WA_PTRV_UTIL_ABZUG_STR-UEBERNACHT sy-vline
WA_PTRV_UTIL_ABZUG_STR-SB_FRSTK sy-vline
WA_PTRV_UTIL_ABZUG_STR-SB_MITAG sy-vline
WA_PTRV_UTIL_ABZUG_STR-SB_ABEND sy-vline
WA_PTRV_UTIL_ABZUG_STR-BRFT_REC_NO sy-vline
WA_PTRV_UTIL_ABZUG_STR-LNCH_REC_NO sy-vline
WA_PTRV_UTIL_ABZUG_STR-DINN_REC_NO sy-vline
WA_PTRV_UTIL_ABZUG_STR-NGHT_TIME sy-vline
WA_PTRV_UTIL_ABZUG_STR-VISIBLEBRE sy-vline
WA_PTRV_UTIL_ABZUG_STR-INPUTBRE sy-vline
WA_PTRV_UTIL_ABZUG_STR-REQUIREDBRE sy-vline
WA_PTRV_UTIL_ABZUG_STR-VISIBLEBRT sy-vline
WA_PTRV_UTIL_ABZUG_STR-INPUTBRT sy-vline
WA_PTRV_UTIL_ABZUG_STR-REQUIREDBRT sy-vline
WA_PTRV_UTIL_ABZUG_STR-VISIBLELNC sy-vline
WA_PTRV_UTIL_ABZUG_STR-INPUTLNC sy-vline
WA_PTRV_UTIL_ABZUG_STR-REQUIREDLNC sy-vline
WA_PTRV_UTIL_ABZUG_STR-VISIBLELNT sy-vline
WA_PTRV_UTIL_ABZUG_STR-INPUTLNT sy-vline
WA_PTRV_UTIL_ABZUG_STR-REQUIREDLNT sy-vline
WA_PTRV_UTIL_ABZUG_STR-VISIBLEDIN sy-vline
WA_PTRV_UTIL_ABZUG_STR-INPUTDIN sy-vline
WA_PTRV_UTIL_ABZUG_STR-REQUIREDDIN sy-vline
WA_PTRV_UTIL_ABZUG_STR-VISIBLEDIT sy-vline
WA_PTRV_UTIL_ABZUG_STR-INPUTDIT sy-vline
WA_PTRV_UTIL_ABZUG_STR-REQUIREDDIT sy-vline
WA_PTRV_UTIL_ABZUG_STR-VISIBLENGT sy-vline
WA_PTRV_UTIL_ABZUG_STR-INPUTNGT sy-vline
WA_PTRV_UTIL_ABZUG_STR-REQUIREDNGT sy-vline
WA_PTRV_UTIL_ABZUG_STR-VISIBLECUP sy-vline
WA_PTRV_UTIL_ABZUG_STR-INPUTCUP sy-vline
WA_PTRV_UTIL_ABZUG_STR-REQUIREDCUP sy-vline
WA_PTRV_UTIL_ABZUG_STR-DISPLAY_ONLY sy-vline
WA_PTRV_UTIL_ABZUG_STR-VISIBLEFSB sy-vline
WA_PTRV_UTIL_ABZUG_STR-INPUTFSB sy-vline
WA_PTRV_UTIL_ABZUG_STR-REQUIREDFSB sy-vline
WA_PTRV_UTIL_ABZUG_STR-VISIBLEMSB sy-vline
WA_PTRV_UTIL_ABZUG_STR-INPUTMSB sy-vline
WA_PTRV_UTIL_ABZUG_STR-REQUIREDMSB sy-vline
WA_PTRV_UTIL_ABZUG_STR-VISIBLEASB sy-vline
WA_PTRV_UTIL_ABZUG_STR-INPUTASB sy-vline
WA_PTRV_UTIL_ABZUG_STR-REQUIREDASB sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.