ABAP Select data from SAP table PUNCMT_A_DEPA into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PUNCMT_A_DEPA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PUNCMT_A_DEPA. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PUNCMT_A_DEPA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PUNCMT_A_DEPA TYPE STANDARD TABLE OF PUNCMT_A_DEPA, WA_PUNCMT_A_DEPA TYPE PUNCMT_A_DEPA, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <PUNCMT_A_DEPA> TYPE PUNCMT_A_DEPA. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_PUNCMT_A_DEPA. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM PUNCMT_A_DEPA INTO TABLE IT_PUNCMT_A_DEPA. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM PUNCMT_A_DEPA * INTO TABLE @DATA(IT_PUNCMT_A_DEPA2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_PUNCMT_A_DEPA INDEX 1 INTO DATA(WA_PUNCMT_A_DEPA2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_PUNCMT_A_DEPA ASSIGNING <PUNCMT_A_DEPA>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<PUNCMT_A_DEPA>-EFF_DATE = 1.
<PUNCMT_A_DEPA>-ENTITL_DATE = 1.
<PUNCMT_A_DEPA>-PROCS_DATE = 1.
<PUNCMT_A_DEPA>-EXPIR_DATE = 1.
<PUNCMT_A_DEPA>-F_CURR_CODE = 1.
ENDLOOP. LOOP AT IT_PUNCMT_A_DEPA INTO WA_PUNCMT_A_DEPA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PUNCMT_A_DEPA-FIRST_CHILD_AMT, sy-vline,
WA_PUNCMT_A_DEPA-DEPND_CHILD_AMT, sy-vline,
WA_PUNCMT_A_DEPA-DISAB_CHILD_AMT, sy-vline,
WA_PUNCMT_A_DEPA-DEPND_CHILD_OFW, sy-vline,
WA_PUNCMT_A_DEPA-DISAB_CHILD_OFW, sy-vline,
WA_PUNCMT_A_DEPA-DEPND_SPUSE_AMT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PUNCMT_A_DEPA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PUNCMT_A_DEPA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PUNCMT_A_DEPA INTO WA_PUNCMT_A_DEPA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PUNCMT_A_DEPA_STR,
EFF_DATE TYPE STRING,
ENTITL_DATE TYPE STRING,
PROCS_DATE TYPE STRING,
EXPIR_DATE TYPE STRING,
F_CURR_CODE TYPE STRING,
FIRST_CHILD_AMT TYPE STRING,
DEPND_CHILD_AMT TYPE STRING,
DISAB_CHILD_AMT TYPE STRING,
DEPND_CHILD_OFW TYPE STRING,
DISAB_CHILD_OFW TYPE STRING,
DEPND_SPUSE_AMT TYPE STRING,
SCDRY_DEPND_AMT TYPE STRING,
OTHER_CHILD_AMT TYPE STRING,
FIRST_CH_SNG_AMT TYPE STRING,
OTHER_CH_SNG_AMT TYPE STRING,
OTHER_CH_WID_AMT TYPE STRING,
F_ADLH_TRAN_SER TYPE STRING,END OF T_EKKO_STR. DATA: WA_PUNCMT_A_DEPA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PUNCMT_A_DEPA_STR-EFF_DATE sy-vline
WA_PUNCMT_A_DEPA_STR-ENTITL_DATE sy-vline
WA_PUNCMT_A_DEPA_STR-PROCS_DATE sy-vline
WA_PUNCMT_A_DEPA_STR-EXPIR_DATE sy-vline
WA_PUNCMT_A_DEPA_STR-F_CURR_CODE sy-vline
WA_PUNCMT_A_DEPA_STR-FIRST_CHILD_AMT sy-vline
WA_PUNCMT_A_DEPA_STR-DEPND_CHILD_AMT sy-vline
WA_PUNCMT_A_DEPA_STR-DISAB_CHILD_AMT sy-vline
WA_PUNCMT_A_DEPA_STR-DEPND_CHILD_OFW sy-vline
WA_PUNCMT_A_DEPA_STR-DISAB_CHILD_OFW sy-vline
WA_PUNCMT_A_DEPA_STR-DEPND_SPUSE_AMT sy-vline
WA_PUNCMT_A_DEPA_STR-SCDRY_DEPND_AMT sy-vline
WA_PUNCMT_A_DEPA_STR-OTHER_CHILD_AMT sy-vline
WA_PUNCMT_A_DEPA_STR-FIRST_CH_SNG_AMT sy-vline
WA_PUNCMT_A_DEPA_STR-OTHER_CH_SNG_AMT sy-vline
WA_PUNCMT_A_DEPA_STR-OTHER_CH_WID_AMT sy-vline
WA_PUNCMT_A_DEPA_STR-F_ADLH_TRAN_SER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.