ABAP Select data from SAP table PWCCAPOPRANGE into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PWCCAPOPRANGE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PWCCAPOPRANGE. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PWCCAPOPRANGE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PWCCAPOPRANGE TYPE STANDARD TABLE OF PWCCAPOPRANGE, WA_PWCCAPOPRANGE TYPE PWCCAPOPRANGE, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <PWCCAPOPRANGE> TYPE PWCCAPOPRANGE. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_PWCCAPOPRANGE. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM PWCCAPOPRANGE INTO TABLE IT_PWCCAPOPRANGE. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM PWCCAPOPRANGE * INTO TABLE @DATA(IT_PWCCAPOPRANGE2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_PWCCAPOPRANGE INDEX 1 INTO DATA(WA_PWCCAPOPRANGE2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_PWCCAPOPRANGE ASSIGNING <PWCCAPOPRANGE>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<PWCCAPOPRANGE>-MANDT = 1.
<PWCCAPOPRANGE>-WORKCENTERINTERNALID = 1.
<PWCCAPOPRANGE>-WORKCENTERTYPECODE = 1.
<PWCCAPOPRANGE>-CAPACITYCATEGORYALLOCATION = 1.
<PWCCAPOPRANGE>-CAPACITYINTERNALID = 1.
ENDLOOP. LOOP AT IT_PWCCAPOPRANGE INTO WA_PWCCAPOPRANGE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PWCCAPOPRANGE-ORDERID, sy-vline,
WA_PWCCAPOPRANGE-OPERATION, sy-vline,
WA_PWCCAPOPRANGE-CAPACITYREQUIREMENT, sy-vline,
WA_PWCCAPOPRANGE-MATERIAL, sy-vline,
WA_PWCCAPOPRANGE-PLANT, sy-vline,
WA_PWCCAPOPRANGE-MRPCONTROLLER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PWCCAPOPRANGE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PWCCAPOPRANGE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PWCCAPOPRANGE INTO WA_PWCCAPOPRANGE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit NUMCV, internal->external for field OPERATION CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_PWCCAPOPRANGE-OPERATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PWCCAPOPRANGE-OPERATION.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PWCCAPOPRANGE-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PWCCAPOPRANGE-MATERIAL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field CAPACITYREQUIREMENTUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PWCCAPOPRANGE-CAPACITYREQUIREMENTUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PWCCAPOPRANGE-CAPACITYREQUIREMENTUNIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field BASEUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PWCCAPOPRANGE-BASEUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PWCCAPOPRANGE-BASEUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PWCCAPOPRANGE_STR,
MANDT TYPE STRING,
WORKCENTERINTERNALID TYPE STRING,
WORKCENTERTYPECODE TYPE STRING,
CAPACITYCATEGORYALLOCATION TYPE STRING,
CAPACITYINTERNALID TYPE STRING,
ORDERID TYPE STRING,
OPERATION TYPE STRING,
CAPACITYREQUIREMENT TYPE STRING,
MATERIAL TYPE STRING,
PLANT TYPE STRING,
MRPCONTROLLER TYPE STRING,
WORKCENTER TYPE STRING,
WORKCENTERRESPONSIBLE TYPE STRING,
WORKCENTERCATEGORYCODE TYPE STRING,
CAPACITYREQUIREMENTORIGIN TYPE STRING,
CAPACITYREQUIREMENTUNIT TYPE STRING,
ORDERINTERNALID TYPE STRING,
ORDERTYPE TYPE STRING,
ORDERCATEGORY TYPE STRING,
PRODUCTIONVERSION TYPE STRING,
ORDERPLANNEDTOTALQTY TYPE STRING,
BASEUNIT TYPE STRING,
OPERATIONPLANNINGSTATUSCODE TYPE STRING,
OPERATIONLATESTSTARTDATE TYPE STRING,
OPERATIONLATESTSTARTTIME TYPE STRING,
OPERATIONLATESTENDDATE TYPE STRING,
OPERATIONLATESTENDTIME TYPE STRING,
OPLTSTSCHEDLDEXECSTRTTME TYPE STRING,
OPLTSTSCHEDLDEXECENDTME TYPE STRING,
OPLTSTSCHEDLDPROCGSTRTDTE TYPE STRING,
OPLTSTSCHEDLDPROCGSTRTTME TYPE STRING,
OPLTSTSCHEDLDTRDWNSTRTDTE TYPE STRING,
OPLTSTSCHEDLDTRDWNSTRTTME TYPE STRING,
REMAININGCAPREQOPSEGSETUPDURN TYPE STRING,
REMAININGCAPREQOPSEGPROCGDURN TYPE STRING,
REMAININGCAPREQOPSEGTRDWNDURN TYPE STRING,
CAPACITYREQUIREMENTSAREDTMND TYPE STRING,
TOTREQUIREMENTINSECONDS TYPE STRING,
ORDERSTATUSCODE TYPE STRING,
ORDERFIRMINGSTATUSCODE TYPE STRING,END OF T_EKKO_STR. DATA: WA_PWCCAPOPRANGE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PWCCAPOPRANGE_STR-MANDT sy-vline
WA_PWCCAPOPRANGE_STR-WORKCENTERINTERNALID sy-vline
WA_PWCCAPOPRANGE_STR-WORKCENTERTYPECODE sy-vline
WA_PWCCAPOPRANGE_STR-CAPACITYCATEGORYALLOCATION sy-vline
WA_PWCCAPOPRANGE_STR-CAPACITYINTERNALID sy-vline
WA_PWCCAPOPRANGE_STR-ORDERID sy-vline
WA_PWCCAPOPRANGE_STR-OPERATION sy-vline
WA_PWCCAPOPRANGE_STR-CAPACITYREQUIREMENT sy-vline
WA_PWCCAPOPRANGE_STR-MATERIAL sy-vline
WA_PWCCAPOPRANGE_STR-PLANT sy-vline
WA_PWCCAPOPRANGE_STR-MRPCONTROLLER sy-vline
WA_PWCCAPOPRANGE_STR-WORKCENTER sy-vline
WA_PWCCAPOPRANGE_STR-WORKCENTERRESPONSIBLE sy-vline
WA_PWCCAPOPRANGE_STR-WORKCENTERCATEGORYCODE sy-vline
WA_PWCCAPOPRANGE_STR-CAPACITYREQUIREMENTORIGIN sy-vline
WA_PWCCAPOPRANGE_STR-CAPACITYREQUIREMENTUNIT sy-vline
WA_PWCCAPOPRANGE_STR-ORDERINTERNALID sy-vline
WA_PWCCAPOPRANGE_STR-ORDERTYPE sy-vline
WA_PWCCAPOPRANGE_STR-ORDERCATEGORY sy-vline
WA_PWCCAPOPRANGE_STR-PRODUCTIONVERSION sy-vline
WA_PWCCAPOPRANGE_STR-ORDERPLANNEDTOTALQTY sy-vline
WA_PWCCAPOPRANGE_STR-BASEUNIT sy-vline
WA_PWCCAPOPRANGE_STR-OPERATIONPLANNINGSTATUSCODE sy-vline
WA_PWCCAPOPRANGE_STR-OPERATIONLATESTSTARTDATE sy-vline
WA_PWCCAPOPRANGE_STR-OPERATIONLATESTSTARTTIME sy-vline
WA_PWCCAPOPRANGE_STR-OPERATIONLATESTENDDATE sy-vline
WA_PWCCAPOPRANGE_STR-OPERATIONLATESTENDTIME sy-vline
WA_PWCCAPOPRANGE_STR-OPLTSTSCHEDLDEXECSTRTTME sy-vline
WA_PWCCAPOPRANGE_STR-OPLTSTSCHEDLDEXECENDTME sy-vline
WA_PWCCAPOPRANGE_STR-OPLTSTSCHEDLDPROCGSTRTDTE sy-vline
WA_PWCCAPOPRANGE_STR-OPLTSTSCHEDLDPROCGSTRTTME sy-vline
WA_PWCCAPOPRANGE_STR-OPLTSTSCHEDLDTRDWNSTRTDTE sy-vline
WA_PWCCAPOPRANGE_STR-OPLTSTSCHEDLDTRDWNSTRTTME sy-vline
WA_PWCCAPOPRANGE_STR-REMAININGCAPREQOPSEGSETUPDURN sy-vline
WA_PWCCAPOPRANGE_STR-REMAININGCAPREQOPSEGPROCGDURN sy-vline
WA_PWCCAPOPRANGE_STR-REMAININGCAPREQOPSEGTRDWNDURN sy-vline
WA_PWCCAPOPRANGE_STR-CAPACITYREQUIREMENTSAREDTMND sy-vline
WA_PWCCAPOPRANGE_STR-TOTREQUIREMENTINSECONDS sy-vline
WA_PWCCAPOPRANGE_STR-ORDERSTATUSCODE sy-vline
WA_PWCCAPOPRANGE_STR-ORDERFIRMINGSTATUSCODE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.