ABAP Select data from SAP table PYC_S_PROC_INST_PH_EXPORT into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PYC_S_PROC_INST_PH_EXPORT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PYC_S_PROC_INST_PH_EXPORT. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PYC_S_PROC_INST_PH_EXPORT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PYC_S_PROC_INST_PH_EXPORT TYPE STANDARD TABLE OF PYC_S_PROC_INST_PH_EXPORT, WA_PYC_S_PROC_INST_PH_EXPORT TYPE PYC_S_PROC_INST_PH_EXPORT, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <PYC_S_PROC_INST_PH_EXPORT> TYPE PYC_S_PROC_INST_PH_EXPORT. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_PYC_S_PROC_INST_PH_EXPORT. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM PYC_S_PROC_INST_PH_EXPORT INTO TABLE IT_PYC_S_PROC_INST_PH_EXPORT. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM PYC_S_PROC_INST_PH_EXPORT * INTO TABLE @DATA(IT_PYC_S_PROC_INST_PH_EXPORT2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_PYC_S_PROC_INST_PH_EXPORT INDEX 1 INTO DATA(WA_PYC_S_PROC_INST_PH_EXPORT2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_PYC_S_PROC_INST_PH_EXPORT ASSIGNING <PYC_S_PROC_INST_PH_EXPORT>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<PYC_S_PROC_INST_PH_EXPORT>-PYPI_ID = 1.
<PYC_S_PROC_INST_PH_EXPORT>-PYPI_NAME = 1.
<PYC_S_PROC_INST_PH_EXPORT>-STEP_ID = 1.
<PYC_S_PROC_INST_PH_EXPORT>-STEP_NAME = 1.
<PYC_S_PROC_INST_PH_EXPORT>-TSL = 1.
ENDLOOP. LOOP AT IT_PYC_S_PROC_INST_PH_EXPORT INTO WA_PYC_S_PROC_INST_PH_EXPORT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PYC_S_PROC_INST_PH_EXPORT-DATE_TIME_UTC, sy-vline,
WA_PYC_S_PROC_INST_PH_EXPORT-DATE_TIME_USER, sy-vline,
WA_PYC_S_PROC_INST_PH_EXPORT-TSL_CHAR, sy-vline,
WA_PYC_S_PROC_INST_PH_EXPORT-TSL_CHAR_USER, sy-vline,
WA_PYC_S_PROC_INST_PH_EXPORT-USER_TZONE, sy-vline,
WA_PYC_S_PROC_INST_PH_EXPORT-USER_NAME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PYC_S_PROC_INST_PH_EXPORT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PYC_S_PROC_INST_PH_EXPORT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PYC_S_PROC_INST_PH_EXPORT INTO WA_PYC_S_PROC_INST_PH_EXPORT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit CKINP, internal->external for field STEP_ID CALL FUNCTION 'CONVERSION_EXIT_CKINP_OUTPUT' EXPORTING input = WA_PYC_S_PROC_INST_PH_EXPORT-STEP_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PYC_S_PROC_INST_PH_EXPORT-STEP_ID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PYC_S_PROC_INST_PH_EXPORT_STR,
PYPI_ID TYPE STRING,
PYPI_NAME TYPE STRING,
STEP_ID TYPE STRING,
STEP_NAME TYPE STRING,
TSL TYPE STRING,
DATE_TIME_UTC TYPE STRING,
DATE_TIME_USER TYPE STRING,
TSL_CHAR TYPE STRING,
TSL_CHAR_USER TYPE STRING,
USER_TZONE TYPE STRING,
USER_NAME TYPE STRING,
USER_FORMATTED_NAME TYPE STRING,
ACTION TYPE STRING,
ACTION_TEXT TYPE STRING,
SEVERITY TYPE STRING,
SEVERITYTEXT TYPE STRING,
HEADER_TEXT TYPE STRING,
FREE_TEXT TYPE STRING,
IS_ATTACHMENT TYPE STRING,
ATTACHMENT_ID TYPE STRING,
IS_SYSTEM_TRIGGERED TYPE STRING,END OF T_EKKO_STR. DATA: WA_PYC_S_PROC_INST_PH_EXPORT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PYC_S_PROC_INST_PH_EXPORT_STR-PYPI_ID sy-vline
WA_PYC_S_PROC_INST_PH_EXPORT_STR-PYPI_NAME sy-vline
WA_PYC_S_PROC_INST_PH_EXPORT_STR-STEP_ID sy-vline
WA_PYC_S_PROC_INST_PH_EXPORT_STR-STEP_NAME sy-vline
WA_PYC_S_PROC_INST_PH_EXPORT_STR-TSL sy-vline
WA_PYC_S_PROC_INST_PH_EXPORT_STR-DATE_TIME_UTC sy-vline
WA_PYC_S_PROC_INST_PH_EXPORT_STR-DATE_TIME_USER sy-vline
WA_PYC_S_PROC_INST_PH_EXPORT_STR-TSL_CHAR sy-vline
WA_PYC_S_PROC_INST_PH_EXPORT_STR-TSL_CHAR_USER sy-vline
WA_PYC_S_PROC_INST_PH_EXPORT_STR-USER_TZONE sy-vline
WA_PYC_S_PROC_INST_PH_EXPORT_STR-USER_NAME sy-vline
WA_PYC_S_PROC_INST_PH_EXPORT_STR-USER_FORMATTED_NAME sy-vline
WA_PYC_S_PROC_INST_PH_EXPORT_STR-ACTION sy-vline
WA_PYC_S_PROC_INST_PH_EXPORT_STR-ACTION_TEXT sy-vline
WA_PYC_S_PROC_INST_PH_EXPORT_STR-SEVERITY sy-vline
WA_PYC_S_PROC_INST_PH_EXPORT_STR-SEVERITYTEXT sy-vline
WA_PYC_S_PROC_INST_PH_EXPORT_STR-HEADER_TEXT sy-vline
WA_PYC_S_PROC_INST_PH_EXPORT_STR-FREE_TEXT sy-vline
WA_PYC_S_PROC_INST_PH_EXPORT_STR-IS_ATTACHMENT sy-vline
WA_PYC_S_PROC_INST_PH_EXPORT_STR-ATTACHMENT_ID sy-vline
WA_PYC_S_PROC_INST_PH_EXPORT_STR-IS_SYSTEM_TRIGGERED sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.