ABAP Select data from SAP table QPCPS_PLAN_UI into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP QPCPS_PLAN_UI table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to QPCPS_PLAN_UI. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the QPCPS_PLAN_UI table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_QPCPS_PLAN_UI TYPE STANDARD TABLE OF QPCPS_PLAN_UI, WA_QPCPS_PLAN_UI TYPE QPCPS_PLAN_UI, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <QPCPS_PLAN_UI> TYPE QPCPS_PLAN_UI. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_QPCPS_PLAN_UI. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM QPCPS_PLAN_UI INTO TABLE IT_QPCPS_PLAN_UI. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM QPCPS_PLAN_UI * INTO TABLE @DATA(IT_QPCPS_PLAN_UI2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_QPCPS_PLAN_UI INDEX 1 INTO DATA(WA_QPCPS_PLAN_UI2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_QPCPS_PLAN_UI ASSIGNING <QPCPS_PLAN_UI>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<QPCPS_PLAN_UI>-CLIENT = 1.
<QPCPS_PLAN_UI>-PLAN_GUID = 1.
<QPCPS_PLAN_UI>-PLAN_ID = 1.
<QPCPS_PLAN_UI>-MATNR = 1.
<QPCPS_PLAN_UI>-MATNR_TEXT = 1.
ENDLOOP. LOOP AT IT_QPCPS_PLAN_UI INTO WA_QPCPS_PLAN_UI. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_QPCPS_PLAN_UI-WERKS, sy-vline,
WA_QPCPS_PLAN_UI-WERKS_TEXT, sy-vline,
WA_QPCPS_PLAN_UI-PART_NUMBER, sy-vline,
WA_QPCPS_PLAN_UI-VENDOR_ID, sy-vline,
WA_QPCPS_PLAN_UI-PLAN_TYPE, sy-vline,
WA_QPCPS_PLAN_UI-SELECTION_DATE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_QPCPS_PLAN_UI you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_QPCPS_PLAN_UI TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_QPCPS_PLAN_UI INTO WA_QPCPS_PLAN_UI. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field PLAN_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_QPCPS_PLAN_UI-PLAN_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_QPCPS_PLAN_UI-PLAN_ID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_QPCPS_PLAN_UI-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_QPCPS_PLAN_UI-MATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field DOKNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_QPCPS_PLAN_UI-DOKNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_QPCPS_PLAN_UI-DOKNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ISOLA, internal->external for field LANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_QPCPS_PLAN_UI-LANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_QPCPS_PLAN_UI-LANGU.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_QPCPS_PLAN_UI_STR,
CLIENT TYPE STRING,
PLAN_GUID TYPE STRING,
PLAN_ID TYPE STRING,
MATNR TYPE STRING,
MATNR_TEXT TYPE STRING,
WERKS TYPE STRING,
WERKS_TEXT TYPE STRING,
PART_NUMBER TYPE STRING,
VENDOR_ID TYPE STRING,
PLAN_TYPE TYPE STRING,
SELECTION_DATE TYPE STRING,
DOKNR TYPE STRING,
DOKAR TYPE STRING,
DOKTL TYPE STRING,
DOKVR TYPE STRING,
CREATED_BY TYPE STRING,
CREATED_ON TYPE STRING,
CHANGED_BY TYPE STRING,
CHANGED_ON TYPE STRING,
RELEASED_BY TYPE STRING,
RELEASED_ON_DATE TYPE STRING,
RELEASED_ON_TIME TYPE STRING,
CUST_REL_CON_ON TYPE STRING,
CUST_REL_QM_ON TYPE STRING,
CHECK_RESULT TYPE STRING,
CHECK_ON_DATE TYPE STRING,
CHECK_ON_TIME TYPE STRING,
PROJECT_ID TYPE STRING,
DELETED TYPE STRING,
TEXT TYPE STRING,
SYSTEM_STATUS_TEXT TYPE STRING,
USER_STATUS_TEXT TYPE STRING,
STATUS_PROFILE TYPE STRING,
LANGU TYPE STRING,END OF T_EKKO_STR. DATA: WA_QPCPS_PLAN_UI_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_QPCPS_PLAN_UI_STR-CLIENT sy-vline
WA_QPCPS_PLAN_UI_STR-PLAN_GUID sy-vline
WA_QPCPS_PLAN_UI_STR-PLAN_ID sy-vline
WA_QPCPS_PLAN_UI_STR-MATNR sy-vline
WA_QPCPS_PLAN_UI_STR-MATNR_TEXT sy-vline
WA_QPCPS_PLAN_UI_STR-WERKS sy-vline
WA_QPCPS_PLAN_UI_STR-WERKS_TEXT sy-vline
WA_QPCPS_PLAN_UI_STR-PART_NUMBER sy-vline
WA_QPCPS_PLAN_UI_STR-VENDOR_ID sy-vline
WA_QPCPS_PLAN_UI_STR-PLAN_TYPE sy-vline
WA_QPCPS_PLAN_UI_STR-SELECTION_DATE sy-vline
WA_QPCPS_PLAN_UI_STR-DOKNR sy-vline
WA_QPCPS_PLAN_UI_STR-DOKAR sy-vline
WA_QPCPS_PLAN_UI_STR-DOKTL sy-vline
WA_QPCPS_PLAN_UI_STR-DOKVR sy-vline
WA_QPCPS_PLAN_UI_STR-CREATED_BY sy-vline
WA_QPCPS_PLAN_UI_STR-CREATED_ON sy-vline
WA_QPCPS_PLAN_UI_STR-CHANGED_BY sy-vline
WA_QPCPS_PLAN_UI_STR-CHANGED_ON sy-vline
WA_QPCPS_PLAN_UI_STR-RELEASED_BY sy-vline
WA_QPCPS_PLAN_UI_STR-RELEASED_ON_DATE sy-vline
WA_QPCPS_PLAN_UI_STR-RELEASED_ON_TIME sy-vline
WA_QPCPS_PLAN_UI_STR-CUST_REL_CON_ON sy-vline
WA_QPCPS_PLAN_UI_STR-CUST_REL_QM_ON sy-vline
WA_QPCPS_PLAN_UI_STR-CHECK_RESULT sy-vline
WA_QPCPS_PLAN_UI_STR-CHECK_ON_DATE sy-vline
WA_QPCPS_PLAN_UI_STR-CHECK_ON_TIME sy-vline
WA_QPCPS_PLAN_UI_STR-PROJECT_ID sy-vline
WA_QPCPS_PLAN_UI_STR-DELETED sy-vline
WA_QPCPS_PLAN_UI_STR-TEXT sy-vline
WA_QPCPS_PLAN_UI_STR-SYSTEM_STATUS_TEXT sy-vline
WA_QPCPS_PLAN_UI_STR-USER_STATUS_TEXT sy-vline
WA_QPCPS_PLAN_UI_STR-STATUS_PROFILE sy-vline
WA_QPCPS_PLAN_UI_STR-LANGU sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.