ABAP Select data from SAP table RC62F into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP RC62F table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RC62F. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the RC62F table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_RC62F TYPE STANDARD TABLE OF RC62F, WA_RC62F TYPE RC62F, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <RC62F> TYPE RC62F. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_RC62F. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM RC62F INTO TABLE IT_RC62F. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM RC62F * INTO TABLE @DATA(IT_RC62F2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_RC62F INDEX 1 INTO DATA(WA_RC62F2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_RC62F ASSIGNING <RC62F>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<RC62F>-NEW_ROUT = 1.
<RC62F>-NEW_BOM = 1.
<RC62F>-AUFLD = 1.
<RC62F>-PLAUF = 1.
<RC62F>-PROD_VERS = 1.
ENDLOOP. LOOP AT IT_RC62F INTO WA_RC62F. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_RC62F-VERTO, sy-vline,
WA_RC62F-REVLV, sy-vline,
WA_RC62F-REV_SEL, sy-vline,
WA_RC62F-VER_SEL, sy-vline,
WA_RC62F-ALT_SEL, sy-vline,
WA_RC62F-NO_SEL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RC62F you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RC62F TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RC62F INTO WA_RC62F. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit NUMCV, internal->external for field REVLV CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_RC62F-REVLV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RC62F-REVLV.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field STLAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RC62F-STLAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RC62F-STLAL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_RC62F-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RC62F-MATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field KDAUF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RC62F-KDAUF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RC62F-KDAUF.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ABPSP, internal->external for field PSPEL CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_RC62F-PSPEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RC62F-PSPEL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RC62F_STR,
NEW_ROUT TYPE STRING,
NEW_BOM TYPE STRING,
AUFLD TYPE STRING,
PLAUF TYPE STRING,
PROD_VERS TYPE STRING,
VERTO TYPE STRING,
REVLV TYPE STRING,
REV_SEL TYPE STRING,
VER_SEL TYPE STRING,
ALT_SEL TYPE STRING,
NO_SEL TYPE STRING,
GSTRP TYPE STRING,
GLTRP TYPE STRING,
LGORT TYPE STRING,
NO_BOM TYPE STRING,
NO_ROU TYPE STRING,
BDTER TYPE STRING,
STLAN TYPE STRING,
STLAL TYPE STRING,
SERNR TYPE STRING,
MATNR TYPE STRING,
WERKS TYPE STRING,
BDMNG TYPE STRING,
CAPID TYPE STRING,
KDAUF TYPE STRING,
KDPOS TYPE STRING,
PSPEL TYPE STRING,END OF T_EKKO_STR. DATA: WA_RC62F_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RC62F_STR-NEW_ROUT sy-vline
WA_RC62F_STR-NEW_BOM sy-vline
WA_RC62F_STR-AUFLD sy-vline
WA_RC62F_STR-PLAUF sy-vline
WA_RC62F_STR-PROD_VERS sy-vline
WA_RC62F_STR-VERTO sy-vline
WA_RC62F_STR-REVLV sy-vline
WA_RC62F_STR-REV_SEL sy-vline
WA_RC62F_STR-VER_SEL sy-vline
WA_RC62F_STR-ALT_SEL sy-vline
WA_RC62F_STR-NO_SEL sy-vline
WA_RC62F_STR-GSTRP sy-vline
WA_RC62F_STR-GLTRP sy-vline
WA_RC62F_STR-LGORT sy-vline
WA_RC62F_STR-NO_BOM sy-vline
WA_RC62F_STR-NO_ROU sy-vline
WA_RC62F_STR-BDTER sy-vline
WA_RC62F_STR-STLAN sy-vline
WA_RC62F_STR-STLAL sy-vline
WA_RC62F_STR-SERNR sy-vline
WA_RC62F_STR-MATNR sy-vline
WA_RC62F_STR-WERKS sy-vline
WA_RC62F_STR-BDMNG sy-vline
WA_RC62F_STR-CAPID sy-vline
WA_RC62F_STR-KDAUF sy-vline
WA_RC62F_STR-KDPOS sy-vline
WA_RC62F_STR-PSPEL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.