ABAP Select data from SAP table RC80D into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP RC80D table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RC80D. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the RC80D table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_RC80D TYPE STANDARD TABLE OF RC80D, WA_RC80D TYPE RC80D, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <RC80D> TYPE RC80D. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_RC80D. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM RC80D INTO TABLE IT_RC80D. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM RC80D * INTO TABLE @DATA(IT_RC80D2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_RC80D INDEX 1 INTO DATA(WA_RC80D2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_RC80D ASSIGNING <RC80D>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<RC80D>-SIGNSTRAT = 1.
<RC80D>-SIGSTTXT = 1.
<RC80D>-SIGN_METHOD = 1.
<RC80D>-FLG_EOSP = 1.
<RC80D>-FLG_CANCEL = 1.
ENDLOOP. LOOP AT IT_RC80D INTO WA_RC80D. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_RC80D-FLG_SYNCH, sy-vline,
WA_RC80D-FLG_NO_AUTH, sy-vline,
WA_RC80D-FLG_NO_SEQ, sy-vline,
WA_RC80D-SIGNAUTH, sy-vline,
WA_RC80D-SIGNSTEP, sy-vline,
WA_RC80D-COUNT_STEP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RC80D you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RC80D TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RC80D INTO WA_RC80D. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RC80D_STR,
SIGNSTRAT TYPE STRING,
SIGSTTXT TYPE STRING,
SIGN_METHOD TYPE STRING,
FLG_EOSP TYPE STRING,
FLG_CANCEL TYPE STRING,
FLG_SYNCH TYPE STRING,
FLG_NO_AUTH TYPE STRING,
FLG_NO_SEQ TYPE STRING,
SIGNAUTH TYPE STRING,
SIGNSTEP TYPE STRING,
COUNT_STEP TYPE STRING,
BUF_SEQ_LINES TYPE STRING,END OF T_EKKO_STR. DATA: WA_RC80D_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RC80D_STR-SIGNSTRAT sy-vline
WA_RC80D_STR-SIGSTTXT sy-vline
WA_RC80D_STR-SIGN_METHOD sy-vline
WA_RC80D_STR-FLG_EOSP sy-vline
WA_RC80D_STR-FLG_CANCEL sy-vline
WA_RC80D_STR-FLG_SYNCH sy-vline
WA_RC80D_STR-FLG_NO_AUTH sy-vline
WA_RC80D_STR-FLG_NO_SEQ sy-vline
WA_RC80D_STR-SIGNAUTH sy-vline
WA_RC80D_STR-SIGNSTEP sy-vline
WA_RC80D_STR-COUNT_STEP sy-vline
WA_RC80D_STR-BUF_SEQ_LINES sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.