ABAP Select data from SAP table RC80T into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP RC80T table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RC80T. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the RC80T table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_RC80T TYPE STANDARD TABLE OF RC80T, WA_RC80T TYPE RC80T, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <RC80T> TYPE RC80T. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_RC80T. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM RC80T INTO TABLE IT_RC80T. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM RC80T * INTO TABLE @DATA(IT_RC80T2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_RC80T INDEX 1 INTO DATA(WA_RC80T2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_RC80T ASSIGNING <RC80T>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<RC80T>-PRED1_TXT = 1.
<RC80T>-PRED2_TXT = 1.
<RC80T>-PRED3_TXT = 1.
<RC80T>-PRED4_TXT = 1.
<RC80T>-PRED5_TXT = 1.
ENDLOOP. LOOP AT IT_RC80T INTO WA_RC80T. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_RC80T-PRED6_TXT, sy-vline,
WA_RC80T-PRED7_TXT, sy-vline,
WA_RC80T-PRED8_TXT, sy-vline,
WA_RC80T-SIGNSTRAT, sy-vline,
WA_RC80T-APPLICID, sy-vline,
WA_RC80T-CONS_ERROR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RC80T you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RC80T TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RC80T INTO WA_RC80T. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RC80T_STR,
PRED1_TXT TYPE STRING,
PRED2_TXT TYPE STRING,
PRED3_TXT TYPE STRING,
PRED4_TXT TYPE STRING,
PRED5_TXT TYPE STRING,
PRED6_TXT TYPE STRING,
PRED7_TXT TYPE STRING,
PRED8_TXT TYPE STRING,
SIGNSTRAT TYPE STRING,
APPLICID TYPE STRING,
CONS_ERROR TYPE STRING,
ACTIVITY TYPE STRING,
FLG_DELETE TYPE STRING,
FLG_CONS_CHECK TYPE STRING,
FUNCTION TYPE STRING,END OF T_EKKO_STR. DATA: WA_RC80T_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RC80T_STR-PRED1_TXT sy-vline
WA_RC80T_STR-PRED2_TXT sy-vline
WA_RC80T_STR-PRED3_TXT sy-vline
WA_RC80T_STR-PRED4_TXT sy-vline
WA_RC80T_STR-PRED5_TXT sy-vline
WA_RC80T_STR-PRED6_TXT sy-vline
WA_RC80T_STR-PRED7_TXT sy-vline
WA_RC80T_STR-PRED8_TXT sy-vline
WA_RC80T_STR-SIGNSTRAT sy-vline
WA_RC80T_STR-APPLICID sy-vline
WA_RC80T_STR-CONS_ERROR sy-vline
WA_RC80T_STR-ACTIVITY sy-vline
WA_RC80T_STR-FLG_DELETE sy-vline
WA_RC80T_STR-FLG_CONS_CHECK sy-vline
WA_RC80T_STR-FUNCTION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.