Below is a number of ABAP code snippets to demonstrate how to select data from SAP RCBUNPACKIOT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RCBUNPACKIOT. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the RCBUNPACKIOT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_RCBUNPACKIOT TYPE STANDARD TABLE OF RCBUNPACKIOT, WA_RCBUNPACKIOT TYPE RCBUNPACKIOT, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <RCBUNPACKIOT> TYPE RCBUNPACKIOT. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_RCBUNPACKIOT. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM RCBUNPACKIOT INTO TABLE IT_RCBUNPACKIOT. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM RCBUNPACKIOT * INTO TABLE @DATA(IT_RCBUNPACKIOT2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_RCBUNPACKIOT INDEX 1 INTO DATA(WA_RCBUNPACKIOT2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_RCBUNPACKIOT ASSIGNING <RCBUNPACKIOT>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<RCBUNPACKIOT>-MARKFLG = 1.
<RCBUNPACKIOT>-SELEFLG = 1.
<RCBUNPACKIOT>-LINENO = 1.
<RCBUNPACKIOT>-LINEMOD = 1.
<RCBUNPACKIOT>-CHCOFLG = 1.
ENDLOOP. LOOP AT IT_RCBUNPACKIOT INTO WA_RCBUNPACKIOT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_RCBUNPACKIOT-LOCKMOD, sy-vline,
WA_RCBUNPACKIOT-INTRFLG, sy-vline,
WA_RCBUNPACKIOT-MANDT, sy-vline,
WA_RCBUNPACKIOT-RECN, sy-vline,
WA_RCBUNPACKIOT-ACTN, sy-vline,
WA_RCBUNPACKIOT-VALFR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RCBUNPACKIOT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RCBUNPACKIOT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RCBUNPACKIOT INTO WA_RCBUNPACKIOT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field RECN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCBUNPACKIOT-RECN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBUNPACKIOT-RECN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field ACTN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCBUNPACKIOT-ACTN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBUNPACKIOT-ACTN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCBUNPACKIOT-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBUNPACKIOT-AENNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field OWNID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCBUNPACKIOT-OWNID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBUNPACKIOT-OWNID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field RECNROOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCBUNPACKIOT-RECNROOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBUNPACKIOT-RECNROOT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field RECNMST CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCBUNPACKIOT-RECNMST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBUNPACKIOT-RECNMST.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field U_MAX_QUANT_IN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RCBUNPACKIOT-U_MAX_QUANT_IN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBUNPACKIOT-U_MAX_QUANT_IN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field U_MAX_QUANT_OUT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RCBUNPACKIOT-U_MAX_QUANT_OUT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBUNPACKIOT-U_MAX_QUANT_OUT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field U_MAX_QUANT_SGL CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RCBUNPACKIOT-U_MAX_QUANT_SGL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBUNPACKIOT-U_MAX_QUANT_SGL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field U_MAX_GRS_WEIGHT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RCBUNPACKIOT-U_MAX_GRS_WEIGHT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBUNPACKIOT-U_MAX_GRS_WEIGHT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RCBUNPACKIOT_STR,
MARKFLG TYPE STRING,
SELEFLG TYPE STRING,
LINENO TYPE STRING,
LINEMOD TYPE STRING,
CHCOFLG TYPE STRING,
LOCKMOD TYPE STRING,
INTRFLG TYPE STRING,
MANDT TYPE STRING,
RECN TYPE STRING,
ACTN TYPE STRING,
VALFR TYPE STRING,
VALTO TYPE STRING,
AENNR TYPE STRING,
DELFLG TYPE STRING,
PARKFLG TYPE STRING,
CRDAT TYPE STRING,
CRNAM TYPE STRING,
UPDDAT TYPE STRING,
UPDNAM TYPE STRING,
SRSID TYPE STRING,
OWNID TYPE STRING,
RECNROOT TYPE STRING,
RECNMST TYPE STRING,
DPOT TYPE STRING,
INSTR_ENCL TYPE STRING,
PACOD_IN TYPE STRING,
PACOD_OUT TYPE STRING,
PACOD_SGL TYPE STRING,
MAX_QUANT_IN TYPE STRING,
U_MAX_QUANT_IN TYPE STRING,
FLG_MAX_QU_IN TYPE STRING,
MAX_QUANT_OUT TYPE STRING,
U_MAX_QUANT_OUT TYPE STRING,
FLG_MAX_QU_OUT TYPE STRING,
MAX_QUANT_SGL TYPE STRING,
U_MAX_QUANT_SGL TYPE STRING,
FLG_MAX_QU_SGL TYPE STRING,
MAX_GROSS_WEIGHT TYPE STRING,
U_MAX_GRS_WEIGHT TYPE STRING,
FLG_MAX_GRS_WGHT TYPE STRING,
IPALL TYPE STRING,
AGREE_AUTHORITIE TYPE STRING,
LWDG TYPE STRING,
DGCL TYPE STRING,
DPOTD TYPE STRING,
LDBC TYPE STRING,
LDBCD TYPE STRING,
PGRO TYPE STRING,
INSTR_ENCL_CAT TYPE STRING,
INSTR_ENCL_D TYPE STRING,
MAX_QU_IN_TXT TYPE STRING,
MAX_QU_OUT_TXT TYPE STRING,
MAX_QU_SGL_TXT TYPE STRING,
MAX_GRS_WGHT_TXT TYPE STRING,
SPROV_COUNT TYPE STRING,END OF T_EKKO_STR. DATA: WA_RCBUNPACKIOT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RCBUNPACKIOT_STR-MARKFLG sy-vline
WA_RCBUNPACKIOT_STR-SELEFLG sy-vline
WA_RCBUNPACKIOT_STR-LINENO sy-vline
WA_RCBUNPACKIOT_STR-LINEMOD sy-vline
WA_RCBUNPACKIOT_STR-CHCOFLG sy-vline
WA_RCBUNPACKIOT_STR-LOCKMOD sy-vline
WA_RCBUNPACKIOT_STR-INTRFLG sy-vline
WA_RCBUNPACKIOT_STR-MANDT sy-vline
WA_RCBUNPACKIOT_STR-RECN sy-vline
WA_RCBUNPACKIOT_STR-ACTN sy-vline
WA_RCBUNPACKIOT_STR-VALFR sy-vline
WA_RCBUNPACKIOT_STR-VALTO sy-vline
WA_RCBUNPACKIOT_STR-AENNR sy-vline
WA_RCBUNPACKIOT_STR-DELFLG sy-vline
WA_RCBUNPACKIOT_STR-PARKFLG sy-vline
WA_RCBUNPACKIOT_STR-CRDAT sy-vline
WA_RCBUNPACKIOT_STR-CRNAM sy-vline
WA_RCBUNPACKIOT_STR-UPDDAT sy-vline
WA_RCBUNPACKIOT_STR-UPDNAM sy-vline
WA_RCBUNPACKIOT_STR-SRSID sy-vline
WA_RCBUNPACKIOT_STR-OWNID sy-vline
WA_RCBUNPACKIOT_STR-RECNROOT sy-vline
WA_RCBUNPACKIOT_STR-RECNMST sy-vline
WA_RCBUNPACKIOT_STR-DPOT sy-vline
WA_RCBUNPACKIOT_STR-INSTR_ENCL sy-vline
WA_RCBUNPACKIOT_STR-PACOD_IN sy-vline
WA_RCBUNPACKIOT_STR-PACOD_OUT sy-vline
WA_RCBUNPACKIOT_STR-PACOD_SGL sy-vline
WA_RCBUNPACKIOT_STR-MAX_QUANT_IN sy-vline
WA_RCBUNPACKIOT_STR-U_MAX_QUANT_IN sy-vline
WA_RCBUNPACKIOT_STR-FLG_MAX_QU_IN sy-vline
WA_RCBUNPACKIOT_STR-MAX_QUANT_OUT sy-vline
WA_RCBUNPACKIOT_STR-U_MAX_QUANT_OUT sy-vline
WA_RCBUNPACKIOT_STR-FLG_MAX_QU_OUT sy-vline
WA_RCBUNPACKIOT_STR-MAX_QUANT_SGL sy-vline
WA_RCBUNPACKIOT_STR-U_MAX_QUANT_SGL sy-vline
WA_RCBUNPACKIOT_STR-FLG_MAX_QU_SGL sy-vline
WA_RCBUNPACKIOT_STR-MAX_GROSS_WEIGHT sy-vline
WA_RCBUNPACKIOT_STR-U_MAX_GRS_WEIGHT sy-vline
WA_RCBUNPACKIOT_STR-FLG_MAX_GRS_WGHT sy-vline
WA_RCBUNPACKIOT_STR-IPALL sy-vline
WA_RCBUNPACKIOT_STR-AGREE_AUTHORITIE sy-vline
WA_RCBUNPACKIOT_STR-LWDG sy-vline
WA_RCBUNPACKIOT_STR-DGCL sy-vline
WA_RCBUNPACKIOT_STR-DPOTD sy-vline
WA_RCBUNPACKIOT_STR-LDBC sy-vline
WA_RCBUNPACKIOT_STR-LDBCD sy-vline
WA_RCBUNPACKIOT_STR-PGRO sy-vline
WA_RCBUNPACKIOT_STR-INSTR_ENCL_CAT sy-vline
WA_RCBUNPACKIOT_STR-INSTR_ENCL_D sy-vline
WA_RCBUNPACKIOT_STR-MAX_QU_IN_TXT sy-vline
WA_RCBUNPACKIOT_STR-MAX_QU_OUT_TXT sy-vline
WA_RCBUNPACKIOT_STR-MAX_QU_SGL_TXT sy-vline
WA_RCBUNPACKIOT_STR-MAX_GRS_WGHT_TXT sy-vline
WA_RCBUNPACKIOT_STR-SPROV_COUNT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.