ABAP Select data from SAP table RCG_BW_SPEC_MAT into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP RCG_BW_SPEC_MAT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RCG_BW_SPEC_MAT. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the RCG_BW_SPEC_MAT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_RCG_BW_SPEC_MAT TYPE STANDARD TABLE OF RCG_BW_SPEC_MAT, WA_RCG_BW_SPEC_MAT TYPE RCG_BW_SPEC_MAT, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <RCG_BW_SPEC_MAT> TYPE RCG_BW_SPEC_MAT. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_RCG_BW_SPEC_MAT. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM RCG_BW_SPEC_MAT INTO TABLE IT_RCG_BW_SPEC_MAT. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM RCG_BW_SPEC_MAT * INTO TABLE @DATA(IT_RCG_BW_SPEC_MAT2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_RCG_BW_SPEC_MAT INDEX 1 INTO DATA(WA_RCG_BW_SPEC_MAT2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_RCG_BW_SPEC_MAT ASSIGNING <RCG_BW_SPEC_MAT>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<RCG_BW_SPEC_MAT>-UPDDATS = 1.
<RCG_BW_SPEC_MAT>-RECORDMODE = 1.
<RCG_BW_SPEC_MAT>-WERKS = 1.
<RCG_BW_SPEC_MAT>-MATNR = 1.
<RCG_BW_SPEC_MAT>-SUBID = 1.
ENDLOOP. LOOP AT IT_RCG_BW_SPEC_MAT INTO WA_RCG_BW_SPEC_MAT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_RCG_BW_SPEC_MAT-COMPAVG, sy-vline,
WA_RCG_BW_SPEC_MAT-COMPEXP, sy-vline,
ENDLOOP. *Add any further fields from structure WA_RCG_BW_SPEC_MAT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RCG_BW_SPEC_MAT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RCG_BW_SPEC_MAT INTO WA_RCG_BW_SPEC_MAT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_RCG_BW_SPEC_MAT-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCG_BW_SPEC_MAT-MATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit SPEC1, internal->external for field SUBID CALL FUNCTION 'CONVERSION_EXIT_SPEC1_OUTPUT' EXPORTING input = WA_RCG_BW_SPEC_MAT-SUBID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCG_BW_SPEC_MAT-SUBID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field COMPEXP CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RCG_BW_SPEC_MAT-COMPEXP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCG_BW_SPEC_MAT-COMPEXP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RCG_BW_SPEC_MAT_STR,
UPDDATS TYPE STRING,
RECORDMODE TYPE STRING,
WERKS TYPE STRING,
MATNR TYPE STRING,
SUBID TYPE STRING,
COMPAVG TYPE STRING,
COMPEXP TYPE STRING,END OF T_EKKO_STR. DATA: WA_RCG_BW_SPEC_MAT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RCG_BW_SPEC_MAT_STR-UPDDATS sy-vline
WA_RCG_BW_SPEC_MAT_STR-RECORDMODE sy-vline
WA_RCG_BW_SPEC_MAT_STR-WERKS sy-vline
WA_RCG_BW_SPEC_MAT_STR-MATNR sy-vline
WA_RCG_BW_SPEC_MAT_STR-SUBID sy-vline
WA_RCG_BW_SPEC_MAT_STR-COMPAVG sy-vline
WA_RCG_BW_SPEC_MAT_STR-COMPEXP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.