ABAP Select data from SAP table RCGCDESTDU into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP RCGCDESTDU table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RCGCDESTDU. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the RCGCDESTDU table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_RCGCDESTDU TYPE STANDARD TABLE OF RCGCDESTDU, WA_RCGCDESTDU TYPE RCGCDESTDU, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <RCGCDESTDU> TYPE RCGCDESTDU. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_RCGCDESTDU. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM RCGCDESTDU INTO TABLE IT_RCGCDESTDU. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM RCGCDESTDU * INTO TABLE @DATA(IT_RCGCDESTDU2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_RCGCDESTDU INDEX 1 INTO DATA(WA_RCGCDESTDU2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_RCGCDESTDU ASSIGNING <RCGCDESTDU>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<RCGCDESTDU>-OBJECTID = 1.
<RCGCDESTDU>-MANDT = 1.
<RCGCDESTDU>-RECN = 1.
<RCGCDESTDU>-ACTN = 1.
<RCGCDESTDU>-VALFR = 1.
ENDLOOP. LOOP AT IT_RCGCDESTDU INTO WA_RCGCDESTDU. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_RCGCDESTDU-VALTO, sy-vline,
WA_RCGCDESTDU-AENNR, sy-vline,
WA_RCGCDESTDU-DELFLG, sy-vline,
WA_RCGCDESTDU-PARKFLG, sy-vline,
WA_RCGCDESTDU-CRDAT, sy-vline,
WA_RCGCDESTDU-CRNAM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RCGCDESTDU you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RCGCDESTDU TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RCGCDESTDU INTO WA_RCGCDESTDU. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field RECN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCGCDESTDU-RECN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCGCDESTDU-RECN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field ACTN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCGCDESTDU-ACTN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCGCDESTDU-ACTN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCGCDESTDU-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCGCDESTDU-AENNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field OWNID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCGCDESTDU-OWNID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCGCDESTDU-OWNID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field RECNROOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCGCDESTDU-RECNROOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCGCDESTDU-RECNROOT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field RECNMST CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCGCDESTDU-RECNMST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCGCDESTDU-RECNMST.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RCGCDESTDU_STR,
OBJECTID TYPE STRING,
MANDT TYPE STRING,
RECN TYPE STRING,
ACTN TYPE STRING,
VALFR TYPE STRING,
VALTO TYPE STRING,
AENNR TYPE STRING,
DELFLG TYPE STRING,
PARKFLG TYPE STRING,
CRDAT TYPE STRING,
CRNAM TYPE STRING,
UPDDAT TYPE STRING,
UPDNAM TYPE STRING,
SRSID TYPE STRING,
OWNID TYPE STRING,
RECNROOT TYPE STRING,
NAMEMST TYPE STRING,
RECNMST TYPE STRING,
VACLID TYPE STRING,
RVLID TYPE STRING,
EXCLFLG TYPE STRING,
ACTVFLG TYPE STRING,
ESNTFLG TYPE STRING,
KZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_RCGCDESTDU_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RCGCDESTDU_STR-OBJECTID sy-vline
WA_RCGCDESTDU_STR-MANDT sy-vline
WA_RCGCDESTDU_STR-RECN sy-vline
WA_RCGCDESTDU_STR-ACTN sy-vline
WA_RCGCDESTDU_STR-VALFR sy-vline
WA_RCGCDESTDU_STR-VALTO sy-vline
WA_RCGCDESTDU_STR-AENNR sy-vline
WA_RCGCDESTDU_STR-DELFLG sy-vline
WA_RCGCDESTDU_STR-PARKFLG sy-vline
WA_RCGCDESTDU_STR-CRDAT sy-vline
WA_RCGCDESTDU_STR-CRNAM sy-vline
WA_RCGCDESTDU_STR-UPDDAT sy-vline
WA_RCGCDESTDU_STR-UPDNAM sy-vline
WA_RCGCDESTDU_STR-SRSID sy-vline
WA_RCGCDESTDU_STR-OWNID sy-vline
WA_RCGCDESTDU_STR-RECNROOT sy-vline
WA_RCGCDESTDU_STR-NAMEMST sy-vline
WA_RCGCDESTDU_STR-RECNMST sy-vline
WA_RCGCDESTDU_STR-VACLID sy-vline
WA_RCGCDESTDU_STR-RVLID sy-vline
WA_RCGCDESTDU_STR-EXCLFLG sy-vline
WA_RCGCDESTDU_STR-ACTVFLG sy-vline
WA_RCGCDESTDU_STR-ESNTFLG sy-vline
WA_RCGCDESTDU_STR-KZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.