ABAP Select data from SAP table RCNCOMP into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP RCNCOMP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RCNCOMP. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the RCNCOMP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_RCNCOMP TYPE STANDARD TABLE OF RCNCOMP, WA_RCNCOMP TYPE RCNCOMP, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <RCNCOMP> TYPE RCNCOMP. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_RCNCOMP. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM RCNCOMP INTO TABLE IT_RCNCOMP. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM RCNCOMP * INTO TABLE @DATA(IT_RCNCOMP2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_RCNCOMP INDEX 1 INTO DATA(WA_RCNCOMP2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_RCNCOMP ASSIGNING <RCNCOMP>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<RCNCOMP>-RSNUM = 1.
<RCNCOMP>-RSPOS = 1.
<RCNCOMP>-RSART = 1.
<RCNCOMP>-BANFN = 1.
<RCNCOMP>-BNFPO = 1.
ENDLOOP. LOOP AT IT_RCNCOMP INTO WA_RCNCOMP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_RCNCOMP-LFDAT_BNF, sy-vline,
WA_RCNCOMP-ENMNG_SUM, sy-vline,
WA_RCNCOMP-ENDAT_MAX, sy-vline,
WA_RCNCOMP-WEMNG_SUM, sy-vline,
WA_RCNCOMP-WEDAT_MAX, sy-vline,
WA_RCNCOMP-MEINS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RCNCOMP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RCNCOMP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RCNCOMP INTO WA_RCNCOMP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field BANFN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCNCOMP-BANFN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCNCOMP-BANFN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RCNCOMP-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCNCOMP-MEINS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_RCNCOMP-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCNCOMP-MATNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RCNCOMP_STR,
RSNUM TYPE STRING,
RSPOS TYPE STRING,
RSART TYPE STRING,
BANFN TYPE STRING,
BNFPO TYPE STRING,
LFDAT_BNF TYPE STRING,
ENMNG_SUM TYPE STRING,
ENDAT_MAX TYPE STRING,
WEMNG_SUM TYPE STRING,
WEDAT_MAX TYPE STRING,
MEINS TYPE STRING,
BDTER TYPE STRING,
MATNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_RCNCOMP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RCNCOMP_STR-RSNUM sy-vline
WA_RCNCOMP_STR-RSPOS sy-vline
WA_RCNCOMP_STR-RSART sy-vline
WA_RCNCOMP_STR-BANFN sy-vline
WA_RCNCOMP_STR-BNFPO sy-vline
WA_RCNCOMP_STR-LFDAT_BNF sy-vline
WA_RCNCOMP_STR-ENMNG_SUM sy-vline
WA_RCNCOMP_STR-ENDAT_MAX sy-vline
WA_RCNCOMP_STR-WEMNG_SUM sy-vline
WA_RCNCOMP_STR-WEDAT_MAX sy-vline
WA_RCNCOMP_STR-MEINS sy-vline
WA_RCNCOMP_STR-BDTER sy-vline
WA_RCNCOMP_STR-MATNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.