ABAP Select data from SAP table RCPS_OTPT_FRM into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RCPS_OTPT_FRM table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RCPS_OTPT_FRM. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RCPS_OTPT_FRM table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RCPS_OTPT_FRM TYPE STANDARD TABLE OF RCPS_OTPT_FRM,
      WA_RCPS_OTPT_FRM TYPE RCPS_OTPT_FRM,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RCPS_OTPT_FRM> TYPE RCPS_OTPT_FRM.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RCPS_OTPT_FRM.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RCPS_OTPT_FRM
  INTO TABLE IT_RCPS_OTPT_FRM.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RCPS_OTPT_FRM
*  INTO TABLE @DATA(IT_RCPS_OTPT_FRM2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RCPS_OTPT_FRM INDEX 1 INTO DATA(WA_RCPS_OTPT_FRM2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RCPS_OTPT_FRM ASSIGNING <RCPS_OTPT_FRM>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RCPS_OTPT_FRM>-FRMLID = 1.
<RCPS_OTPT_FRM>-HEADER_DATA = 1.
<RCPS_OTPT_FRM>-SUBID = 1.
<RCPS_OTPT_FRM>-SUBCAT = 1.
<RCPS_OTPT_FRM>-AUTHGRP = 1.
ENDLOOP.

LOOP AT IT_RCPS_OTPT_FRM INTO WA_RCPS_OTPT_FRM.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RCPS_OTPT_FRM-CRNAM, sy-vline,
WA_RCPS_OTPT_FRM-CRDAT, sy-vline,
WA_RCPS_OTPT_FRM-UPDNAM, sy-vline,
WA_RCPS_OTPT_FRM-UPDDAT, sy-vline,
WA_RCPS_OTPT_FRM-REM, sy-vline,
WA_RCPS_OTPT_FRM-LOTSIZE_MIN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RCPS_OTPT_FRM you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RCPS_OTPT_FRM TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RCPS_OTPT_FRM INTO WA_RCPS_OTPT_FRM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CHRI2, internal->external for field FRMLID CALL FUNCTION 'CONVERSION_EXIT_CHRI2_OUTPUT' EXPORTING input = WA_RCPS_OTPT_FRM-FRMLID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCPS_OTPT_FRM-FRMLID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CHRI2, internal->external for field SUBID CALL FUNCTION 'CONVERSION_EXIT_CHRI2_OUTPUT' EXPORTING input = WA_RCPS_OTPT_FRM-SUBID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCPS_OTPT_FRM-SUBID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BASE_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RCPS_OTPT_FRM-BASE_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCPS_OTPT_FRM-BASE_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field INP_TGT_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RCPS_OTPT_FRM-INP_TGT_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCPS_OTPT_FRM-INP_TGT_UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RCPS_OTPT_FRM_STR,
FRMLID TYPE STRING,
HEADER_DATA TYPE STRING,
SUBID TYPE STRING,
SUBCAT TYPE STRING,
AUTHGRP TYPE STRING,
CRNAM TYPE STRING,
CRDAT TYPE STRING,
UPDNAM TYPE STRING,
UPDDAT TYPE STRING,
REM TYPE STRING,
LOTSIZE_MIN TYPE STRING,
LOTSIZE_MAX TYPE STRING,
CONS_FLG TYPE STRING,
STEXT_CONSNAME TYPE STRING,
BASE_QUAN TYPE STRING,
BASE_UNIT TYPE STRING,
INP_TGT_QTY TYPE STRING,
INP_TGT_UNIT TYPE STRING,
LAYOUT TYPE STRING,
REAC_FLG TYPE STRING,
AGGR_FLG TYPE STRING,
EVAP_FLG TYPE STRING,
IDENTS TYPE STRING,
RECIPE_DATA TYPE STRING,
APPL_SCOPE TYPE STRING,
IN_OUT TYPE STRING,
LOM TYPE STRING,
LORS TYPE STRING,
COMPOSITION TYPE STRING,
NUTR_COMP TYPE STRING,
NUTR_CON TYPE STRING,
KEY_FIG TYPE STRING,
AGGR TYPE STRING,
OOP TYPE STRING,
COST TYPE STRING,
DIET_SUM TYPE STRING,
DIET_EVAL TYPE STRING,
STANDARD TYPE STRING,
SUBST_PROP TYPE STRING,END OF T_EKKO_STR. DATA: WA_RCPS_OTPT_FRM_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RCPS_OTPT_FRM_STR-FRMLID sy-vline
WA_RCPS_OTPT_FRM_STR-HEADER_DATA sy-vline
WA_RCPS_OTPT_FRM_STR-SUBID sy-vline
WA_RCPS_OTPT_FRM_STR-SUBCAT sy-vline
WA_RCPS_OTPT_FRM_STR-AUTHGRP sy-vline
WA_RCPS_OTPT_FRM_STR-CRNAM sy-vline
WA_RCPS_OTPT_FRM_STR-CRDAT sy-vline
WA_RCPS_OTPT_FRM_STR-UPDNAM sy-vline
WA_RCPS_OTPT_FRM_STR-UPDDAT sy-vline
WA_RCPS_OTPT_FRM_STR-REM sy-vline
WA_RCPS_OTPT_FRM_STR-LOTSIZE_MIN sy-vline
WA_RCPS_OTPT_FRM_STR-LOTSIZE_MAX sy-vline
WA_RCPS_OTPT_FRM_STR-CONS_FLG sy-vline
WA_RCPS_OTPT_FRM_STR-STEXT_CONSNAME sy-vline
WA_RCPS_OTPT_FRM_STR-BASE_QUAN sy-vline
WA_RCPS_OTPT_FRM_STR-BASE_UNIT sy-vline
WA_RCPS_OTPT_FRM_STR-INP_TGT_QTY sy-vline
WA_RCPS_OTPT_FRM_STR-INP_TGT_UNIT sy-vline
WA_RCPS_OTPT_FRM_STR-LAYOUT sy-vline
WA_RCPS_OTPT_FRM_STR-REAC_FLG sy-vline
WA_RCPS_OTPT_FRM_STR-AGGR_FLG sy-vline
WA_RCPS_OTPT_FRM_STR-EVAP_FLG sy-vline
WA_RCPS_OTPT_FRM_STR-IDENTS sy-vline
WA_RCPS_OTPT_FRM_STR-RECIPE_DATA sy-vline
WA_RCPS_OTPT_FRM_STR-APPL_SCOPE sy-vline
WA_RCPS_OTPT_FRM_STR-IN_OUT sy-vline
WA_RCPS_OTPT_FRM_STR-LOM sy-vline
WA_RCPS_OTPT_FRM_STR-LORS sy-vline
WA_RCPS_OTPT_FRM_STR-COMPOSITION sy-vline
WA_RCPS_OTPT_FRM_STR-NUTR_COMP sy-vline
WA_RCPS_OTPT_FRM_STR-NUTR_CON sy-vline
WA_RCPS_OTPT_FRM_STR-KEY_FIG sy-vline
WA_RCPS_OTPT_FRM_STR-AGGR sy-vline
WA_RCPS_OTPT_FRM_STR-OOP sy-vline
WA_RCPS_OTPT_FRM_STR-COST sy-vline
WA_RCPS_OTPT_FRM_STR-DIET_SUM sy-vline
WA_RCPS_OTPT_FRM_STR-DIET_EVAL sy-vline
WA_RCPS_OTPT_FRM_STR-STANDARD sy-vline
WA_RCPS_OTPT_FRM_STR-SUBST_PROP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.