ABAP Select data from SAP table RECP_RC_PL_C into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP RECP_RC_PL_C table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RECP_RC_PL_C. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the RECP_RC_PL_C table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_RECP_RC_PL_C TYPE STANDARD TABLE OF RECP_RC_PL_C, WA_RECP_RC_PL_C TYPE RECP_RC_PL_C, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <RECP_RC_PL_C> TYPE RECP_RC_PL_C. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_RECP_RC_PL_C. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM RECP_RC_PL_C INTO TABLE IT_RECP_RC_PL_C. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM RECP_RC_PL_C * INTO TABLE @DATA(IT_RECP_RC_PL_C2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_RECP_RC_PL_C INDEX 1 INTO DATA(WA_RECP_RC_PL_C2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_RECP_RC_PL_C ASSIGNING <RECP_RC_PL_C>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<RECP_RC_PL_C>-MANDT = 1.
<RECP_RC_PL_C>-INTRENO = 1.
<RECP_RC_PL_C>-INTRENOPL = 1.
<RECP_RC_PL_C>-SEQNO = 1.
<RECP_RC_PL_C>-RCSTATUS = 1.
ENDLOOP. LOOP AT IT_RECP_RC_PL_C INTO WA_RECP_RC_PL_C. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_RECP_RC_PL_C-RCTYPE, sy-vline,
WA_RECP_RC_PL_C-XRCTYPE, sy-vline,
WA_RECP_RC_PL_C-LOCHIER, sy-vline,
WA_RECP_RC_PL_C-XLOCHIER, sy-vline,
WA_RECP_RC_PL_C-PLSUBDIVNO, sy-vline,
WA_RECP_RC_PL_C-PLNO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RECP_RC_PL_C you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RECP_RC_PL_C TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RECP_RC_PL_C INTO WA_RECP_RC_PL_C. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field PLSUBDIVNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RECP_RC_PL_C-PLSUBDIVNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECP_RC_PL_C-PLSUBDIVNO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit PLNO, internal->external for field PLNO CALL FUNCTION 'CONVERSION_EXIT_PLNO_OUTPUT' EXPORTING input = WA_RECP_RC_PL_C-PLNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECP_RC_PL_C-PLNO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field MEASUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RECP_RC_PL_C-MEASUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECP_RC_PL_C-MEASUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RECP_RC_PL_C_STR,
MANDT TYPE STRING,
INTRENO TYPE STRING,
INTRENOPL TYPE STRING,
SEQNO TYPE STRING,
RCSTATUS TYPE STRING,
RCTYPE TYPE STRING,
XRCTYPE TYPE STRING,
LOCHIER TYPE STRING,
XLOCHIER TYPE STRING,
PLSUBDIVNO TYPE STRING,
PLNO TYPE STRING,
XPL TYPE STRING,
VALIDFROM TYPE STRING,
MEASVALUE TYPE STRING,
MEASUNIT TYPE STRING,
PLSURVEYIND TYPE STRING,
GSBER TYPE STRING,
RESPONSIBLE TYPE STRING,
RERF TYPE STRING,
DERF TYPE STRING,
TERF TYPE STRING,
REHER TYPE STRING,
RBEAR TYPE STRING,
DBEAR TYPE STRING,
TBEAR TYPE STRING,
RBHER TYPE STRING,
MEASUNIT_OUT TYPE STRING,END OF T_EKKO_STR. DATA: WA_RECP_RC_PL_C_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RECP_RC_PL_C_STR-MANDT sy-vline
WA_RECP_RC_PL_C_STR-INTRENO sy-vline
WA_RECP_RC_PL_C_STR-INTRENOPL sy-vline
WA_RECP_RC_PL_C_STR-SEQNO sy-vline
WA_RECP_RC_PL_C_STR-RCSTATUS sy-vline
WA_RECP_RC_PL_C_STR-RCTYPE sy-vline
WA_RECP_RC_PL_C_STR-XRCTYPE sy-vline
WA_RECP_RC_PL_C_STR-LOCHIER sy-vline
WA_RECP_RC_PL_C_STR-XLOCHIER sy-vline
WA_RECP_RC_PL_C_STR-PLSUBDIVNO sy-vline
WA_RECP_RC_PL_C_STR-PLNO sy-vline
WA_RECP_RC_PL_C_STR-XPL sy-vline
WA_RECP_RC_PL_C_STR-VALIDFROM sy-vline
WA_RECP_RC_PL_C_STR-MEASVALUE sy-vline
WA_RECP_RC_PL_C_STR-MEASUNIT sy-vline
WA_RECP_RC_PL_C_STR-PLSURVEYIND sy-vline
WA_RECP_RC_PL_C_STR-GSBER sy-vline
WA_RECP_RC_PL_C_STR-RESPONSIBLE sy-vline
WA_RECP_RC_PL_C_STR-RERF sy-vline
WA_RECP_RC_PL_C_STR-DERF sy-vline
WA_RECP_RC_PL_C_STR-TERF sy-vline
WA_RECP_RC_PL_C_STR-REHER sy-vline
WA_RECP_RC_PL_C_STR-RBEAR sy-vline
WA_RECP_RC_PL_C_STR-DBEAR sy-vline
WA_RECP_RC_PL_C_STR-TBEAR sy-vline
WA_RECP_RC_PL_C_STR-RBHER sy-vline
WA_RECP_RC_PL_C_STR-MEASUNIT_OUT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.