ABAP Select data from SAP table RFKIP_SEL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RFKIP_SEL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RFKIP_SEL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RFKIP_SEL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RFKIP_SEL TYPE STANDARD TABLE OF RFKIP_SEL,
      WA_RFKIP_SEL TYPE RFKIP_SEL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RFKIP_SEL> TYPE RFKIP_SEL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RFKIP_SEL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RFKIP_SEL
  INTO TABLE IT_RFKIP_SEL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RFKIP_SEL
*  INTO TABLE @DATA(IT_RFKIP_SEL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RFKIP_SEL INDEX 1 INTO DATA(WA_RFKIP_SEL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RFKIP_SEL ASSIGNING <RFKIP_SEL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RFKIP_SEL>-PDKEY = 1.
<RFKIP_SEL>-PDREF = 1.
<RFKIP_SEL>-WAERS = 1.
<RFKIP_SEL>-GPART = 1.
<RFKIP_SEL>-VKONT = 1.
ENDLOOP.

LOOP AT IT_RFKIP_SEL INTO WA_RFKIP_SEL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RFKIP_SEL-VTREF, sy-vline,
WA_RFKIP_SEL-BROKR, sy-vline,
WA_RFKIP_SEL-GPARV, sy-vline,
WA_RFKIP_SEL-VKONV, sy-vline,
WA_RFKIP_SEL-BUKRS, sy-vline,
WA_RFKIP_SEL-XARCH, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RFKIP_SEL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RFKIP_SEL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RFKIP_SEL INTO WA_RFKIP_SEL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field GPART CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RFKIP_SEL-GPART IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFKIP_SEL-GPART.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VKONT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RFKIP_SEL-VKONT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFKIP_SEL-VKONT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VTREF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RFKIP_SEL-VTREF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFKIP_SEL-VTREF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BROKR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RFKIP_SEL-BROKR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFKIP_SEL-BROKR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field GPARV CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RFKIP_SEL-GPARV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFKIP_SEL-GPARV.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VKONV CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RFKIP_SEL-VKONV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFKIP_SEL-VKONV.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OPBEL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RFKIP_SEL-OPBEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFKIP_SEL-OPBEL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RFKIP_SEL_STR,
PDKEY TYPE STRING,
PDREF TYPE STRING,
WAERS TYPE STRING,
GPART TYPE STRING,
VKONT TYPE STRING,
VTREF TYPE STRING,
BROKR TYPE STRING,
GPARV TYPE STRING,
VKONV TYPE STRING,
BUKRS TYPE STRING,
XARCH TYPE STRING,
OPBEL TYPE STRING,
OPUPW TYPE STRING,
OPUPK TYPE STRING,
OPUPZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_RFKIP_SEL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RFKIP_SEL_STR-PDKEY sy-vline
WA_RFKIP_SEL_STR-PDREF sy-vline
WA_RFKIP_SEL_STR-WAERS sy-vline
WA_RFKIP_SEL_STR-GPART sy-vline
WA_RFKIP_SEL_STR-VKONT sy-vline
WA_RFKIP_SEL_STR-VTREF sy-vline
WA_RFKIP_SEL_STR-BROKR sy-vline
WA_RFKIP_SEL_STR-GPARV sy-vline
WA_RFKIP_SEL_STR-VKONV sy-vline
WA_RFKIP_SEL_STR-BUKRS sy-vline
WA_RFKIP_SEL_STR-XARCH sy-vline
WA_RFKIP_SEL_STR-OPBEL sy-vline
WA_RFKIP_SEL_STR-OPUPW sy-vline
WA_RFKIP_SEL_STR-OPUPK sy-vline
WA_RFKIP_SEL_STR-OPUPZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.