ABAP Select data from SAP table RFMOT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RFMOT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RFMOT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RFMOT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RFMOT TYPE STANDARD TABLE OF RFMOT,
      WA_RFMOT TYPE RFMOT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RFMOT> TYPE RFMOT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RFMOT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RFMOT
  INTO TABLE IT_RFMOT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RFMOT
*  INTO TABLE @DATA(IT_RFMOT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RFMOT INDEX 1 INTO DATA(WA_RFMOT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RFMOT ASSIGNING <RFMOT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RFMOT>-RLDNR = 1.
<RFMOT>-RCOMP = 1.
<RFMOT>-RVERS = 1.
<RFMOT>-RYEAR = 1.
<RFMOT>-FR_PERID = 1.
ENDLOOP.

LOOP AT IT_RFMOT INTO WA_RFMOT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RFMOT-TO_PERID, sy-vline,
WA_RFMOT-RACCT, sy-vline,
WA_RFMOT-RASSC, sy-vline,
WA_RFMOT-RMVCT, sy-vline,
WA_RFMOT-RYACQ, sy-vline,
WA_RFMOT-RPACQ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RFMOT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RFMOT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RFMOT INTO WA_RFMOT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RLDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RFMOT-RLDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFMOT-RLDNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RCOMP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RFMOT-RCOMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFMOT-RCOMP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RVERS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RFMOT-RVERS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFMOT-RVERS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field RYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_RFMOT-RYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFMOT-RYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RACCT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RFMOT-RACCT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFMOT-RACCT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RASSC CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RFMOT-RASSC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFMOT-RASSC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field RYACQ CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_RFMOT-RYACQ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFMOT-RYACQ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field RUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RFMOT-RUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFMOT-RUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RFMOT_STR,
RLDNR TYPE STRING,
RCOMP TYPE STRING,
RVERS TYPE STRING,
RYEAR TYPE STRING,
FR_PERID TYPE STRING,
TO_PERID TYPE STRING,
RACCT TYPE STRING,
RASSC TYPE STRING,
RMVCT TYPE STRING,
RYACQ TYPE STRING,
RPACQ TYPE STRING,
ADFLD1 TYPE STRING,
ADFLD2 TYPE STRING,
ADFLD3 TYPE STRING,
TSL TYPE STRING,
RTCUR TYPE STRING,
HSL TYPE STRING,
LCURR TYPE STRING,
KSL TYPE STRING,
GCURR TYPE STRING,
MSL TYPE STRING,
RUNIT TYPE STRING,END OF T_EKKO_STR. DATA: WA_RFMOT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RFMOT_STR-RLDNR sy-vline
WA_RFMOT_STR-RCOMP sy-vline
WA_RFMOT_STR-RVERS sy-vline
WA_RFMOT_STR-RYEAR sy-vline
WA_RFMOT_STR-FR_PERID sy-vline
WA_RFMOT_STR-TO_PERID sy-vline
WA_RFMOT_STR-RACCT sy-vline
WA_RFMOT_STR-RASSC sy-vline
WA_RFMOT_STR-RMVCT sy-vline
WA_RFMOT_STR-RYACQ sy-vline
WA_RFMOT_STR-RPACQ sy-vline
WA_RFMOT_STR-ADFLD1 sy-vline
WA_RFMOT_STR-ADFLD2 sy-vline
WA_RFMOT_STR-ADFLD3 sy-vline
WA_RFMOT_STR-TSL sy-vline
WA_RFMOT_STR-RTCUR sy-vline
WA_RFMOT_STR-HSL sy-vline
WA_RFMOT_STR-LCURR sy-vline
WA_RFMOT_STR-KSL sy-vline
WA_RFMOT_STR-GCURR sy-vline
WA_RFMOT_STR-MSL sy-vline
WA_RFMOT_STR-RUNIT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.