ABAP Select data from SAP table RFVICPTLTEXT into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP RFVICPTLTEXT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RFVICPTLTEXT. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the RFVICPTLTEXT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_RFVICPTLTEXT TYPE STANDARD TABLE OF RFVICPTLTEXT, WA_RFVICPTLTEXT TYPE RFVICPTLTEXT, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <RFVICPTLTEXT> TYPE RFVICPTLTEXT. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_RFVICPTLTEXT. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM RFVICPTLTEXT INTO TABLE IT_RFVICPTLTEXT. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM RFVICPTLTEXT * INTO TABLE @DATA(IT_RFVICPTLTEXT2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_RFVICPTLTEXT INDEX 1 INTO DATA(WA_RFVICPTLTEXT2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_RFVICPTLTEXT ASSIGNING <RFVICPTLTEXT>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<RFVICPTLTEXT>-RANTYP = 1.
<RFVICPTLTEXT>-SUBANWDG = 1.
<RFVICPTLTEXT>-BRFNM = 1.
<RFVICPTLTEXT>-BSTLF = 1.
<RFVICPTLTEXT>-TDOBJECT = 1.
ENDLOOP. LOOP AT IT_RFVICPTLTEXT INTO WA_RFVICPTLTEXT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_RFVICPTLTEXT-TDNAME, sy-vline,
WA_RFVICPTLTEXT-TDID, sy-vline,
WA_RFVICPTLTEXT-TDSPRAS, sy-vline,
WA_RFVICPTLTEXT-REPID, sy-vline,
WA_RFVICPTLTEXT-SUBROUTINE, sy-vline,
WA_RFVICPTLTEXT-AUSWAHL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RFVICPTLTEXT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RFVICPTLTEXT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RFVICPTLTEXT INTO WA_RFVICPTLTEXT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ISOLA, internal->external for field TDSPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_RFVICPTLTEXT-TDSPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFVICPTLTEXT-TDSPRAS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ISOLA, internal->external for field TDOSPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_RFVICPTLTEXT-TDOSPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFVICPTLTEXT-TDOSPRAS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RFVICPTLTEXT_STR,
RANTYP TYPE STRING,
SUBANWDG TYPE STRING,
BRFNM TYPE STRING,
BSTLF TYPE STRING,
TDOBJECT TYPE STRING,
TDNAME TYPE STRING,
TDID TYPE STRING,
TDSPRAS TYPE STRING,
REPID TYPE STRING,
SUBROUTINE TYPE STRING,
AUSWAHL TYPE STRING,
BST_OBL TYPE STRING,
KOPF_BER TYPE STRING,
TDFRELES TYPE STRING,
TDFUSER TYPE STRING,
TDFDATE TYPE STRING,
TDFTIME TYPE STRING,
TDLRELES TYPE STRING,
TDLUSER TYPE STRING,
TDLDATE TYPE STRING,
TDLTIME TYPE STRING,
TDVERSION TYPE STRING,
TDSTYLE TYPE STRING,
TDFORM TYPE STRING,
TDHYPHENAT TYPE STRING,
TDTRANSTAT TYPE STRING,
TDOSPRAS TYPE STRING,
POSTEXTHEAD TYPE STRING,
POSTEXTLINE TYPE STRING,
TDFORMAT TYPE STRING,
TDLINE TYPE STRING,
TDSYMCOUNT TYPE STRING,
ROWCOLOR TYPE STRING,END OF T_EKKO_STR. DATA: WA_RFVICPTLTEXT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RFVICPTLTEXT_STR-RANTYP sy-vline
WA_RFVICPTLTEXT_STR-SUBANWDG sy-vline
WA_RFVICPTLTEXT_STR-BRFNM sy-vline
WA_RFVICPTLTEXT_STR-BSTLF sy-vline
WA_RFVICPTLTEXT_STR-TDOBJECT sy-vline
WA_RFVICPTLTEXT_STR-TDNAME sy-vline
WA_RFVICPTLTEXT_STR-TDID sy-vline
WA_RFVICPTLTEXT_STR-TDSPRAS sy-vline
WA_RFVICPTLTEXT_STR-REPID sy-vline
WA_RFVICPTLTEXT_STR-SUBROUTINE sy-vline
WA_RFVICPTLTEXT_STR-AUSWAHL sy-vline
WA_RFVICPTLTEXT_STR-BST_OBL sy-vline
WA_RFVICPTLTEXT_STR-KOPF_BER sy-vline
WA_RFVICPTLTEXT_STR-TDFRELES sy-vline
WA_RFVICPTLTEXT_STR-TDFUSER sy-vline
WA_RFVICPTLTEXT_STR-TDFDATE sy-vline
WA_RFVICPTLTEXT_STR-TDFTIME sy-vline
WA_RFVICPTLTEXT_STR-TDLRELES sy-vline
WA_RFVICPTLTEXT_STR-TDLUSER sy-vline
WA_RFVICPTLTEXT_STR-TDLDATE sy-vline
WA_RFVICPTLTEXT_STR-TDLTIME sy-vline
WA_RFVICPTLTEXT_STR-TDVERSION sy-vline
WA_RFVICPTLTEXT_STR-TDSTYLE sy-vline
WA_RFVICPTLTEXT_STR-TDFORM sy-vline
WA_RFVICPTLTEXT_STR-TDHYPHENAT sy-vline
WA_RFVICPTLTEXT_STR-TDTRANSTAT sy-vline
WA_RFVICPTLTEXT_STR-TDOSPRAS sy-vline
WA_RFVICPTLTEXT_STR-POSTEXTHEAD sy-vline
WA_RFVICPTLTEXT_STR-POSTEXTLINE sy-vline
WA_RFVICPTLTEXT_STR-TDFORMAT sy-vline
WA_RFVICPTLTEXT_STR-TDLINE sy-vline
WA_RFVICPTLTEXT_STR-TDSYMCOUNT sy-vline
WA_RFVICPTLTEXT_STR-ROWCOLOR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.