ABAP Select data from SAP table RJGBR_CONTR_HIERA0200 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP RJGBR_CONTR_HIERA0200 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RJGBR_CONTR_HIERA0200. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the RJGBR_CONTR_HIERA0200 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_RJGBR_CONTR_HIERA0200 TYPE STANDARD TABLE OF RJGBR_CONTR_HIERA0200, WA_RJGBR_CONTR_HIERA0200 TYPE RJGBR_CONTR_HIERA0200, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <RJGBR_CONTR_HIERA0200> TYPE RJGBR_CONTR_HIERA0200. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_RJGBR_CONTR_HIERA0200. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM RJGBR_CONTR_HIERA0200 INTO TABLE IT_RJGBR_CONTR_HIERA0200. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM RJGBR_CONTR_HIERA0200 * INTO TABLE @DATA(IT_RJGBR_CONTR_HIERA02002). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_RJGBR_CONTR_HIERA0200 INDEX 1 INTO DATA(WA_RJGBR_CONTR_HIERA02002). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_RJGBR_CONTR_HIERA0200 ASSIGNING <RJGBR_CONTR_HIERA0200>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<RJGBR_CONTR_HIERA0200>-HITYP = 1.
<RJGBR_CONTR_HIERA0200>-GPUNT = 1.
<RJGBR_CONTR_HIERA0200>-GPUEB = 1.
<RJGBR_CONTR_HIERA0200>-GUELTIGAB = 1.
<RJGBR_CONTR_HIERA0200>-GUELTIGBIS = 1.
ENDLOOP. LOOP AT IT_RJGBR_CONTR_HIERA0200 INTO WA_RJGBR_CONTR_HIERA0200. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_RJGBR_CONTR_HIERA0200-PROZ_BEZ, sy-vline,
WA_RJGBR_CONTR_HIERA0200-ERFUSER, sy-vline,
WA_RJGBR_CONTR_HIERA0200-ERFDATE, sy-vline,
WA_RJGBR_CONTR_HIERA0200-ERFTIME, sy-vline,
WA_RJGBR_CONTR_HIERA0200-AENUSER, sy-vline,
WA_RJGBR_CONTR_HIERA0200-AENDATE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RJGBR_CONTR_HIERA0200 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RJGBR_CONTR_HIERA0200 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RJGBR_CONTR_HIERA0200 INTO WA_RJGBR_CONTR_HIERA0200. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field GPUNT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RJGBR_CONTR_HIERA0200-GPUNT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RJGBR_CONTR_HIERA0200-GPUNT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field GPUEB CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RJGBR_CONTR_HIERA0200-GPUEB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RJGBR_CONTR_HIERA0200-GPUEB.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RJGBR_CONTR_HIERA0200_STR,
HITYP TYPE STRING,
GPUNT TYPE STRING,
GPUEB TYPE STRING,
GUELTIGAB TYPE STRING,
GUELTIGBIS TYPE STRING,
PROZ_BEZ TYPE STRING,
ERFUSER TYPE STRING,
ERFDATE TYPE STRING,
ERFTIME TYPE STRING,
AENUSER TYPE STRING,
AENDATE TYPE STRING,
AENTIME TYPE STRING,END OF T_EKKO_STR. DATA: WA_RJGBR_CONTR_HIERA0200_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RJGBR_CONTR_HIERA0200_STR-HITYP sy-vline
WA_RJGBR_CONTR_HIERA0200_STR-GPUNT sy-vline
WA_RJGBR_CONTR_HIERA0200_STR-GPUEB sy-vline
WA_RJGBR_CONTR_HIERA0200_STR-GUELTIGAB sy-vline
WA_RJGBR_CONTR_HIERA0200_STR-GUELTIGBIS sy-vline
WA_RJGBR_CONTR_HIERA0200_STR-PROZ_BEZ sy-vline
WA_RJGBR_CONTR_HIERA0200_STR-ERFUSER sy-vline
WA_RJGBR_CONTR_HIERA0200_STR-ERFDATE sy-vline
WA_RJGBR_CONTR_HIERA0200_STR-ERFTIME sy-vline
WA_RJGBR_CONTR_HIERA0200_STR-AENUSER sy-vline
WA_RJGBR_CONTR_HIERA0200_STR-AENDATE sy-vline
WA_RJGBR_CONTR_HIERA0200_STR-AENTIME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.