ABAP Select data from SAP table RK70P_T into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RK70P_T table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RK70P_T. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RK70P_T table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RK70P_T TYPE STANDARD TABLE OF RK70P_T,
      WA_RK70P_T TYPE RK70P_T,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RK70P_T> TYPE RK70P_T.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RK70P_T.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RK70P_T
  INTO TABLE IT_RK70P_T.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RK70P_T
*  INTO TABLE @DATA(IT_RK70P_T2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RK70P_T INDEX 1 INTO DATA(WA_RK70P_T2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RK70P_T ASSIGNING <RK70P_T>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RK70P_T>-PMARK = 1.
<RK70P_T>-POSNR = 1.
<RK70P_T>-TYPPS = 1.
<RK70P_T>-LTEXT = 1.
ENDLOOP.

LOOP AT IT_RK70P_T INTO WA_RK70P_T.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline, ENDLOOP.
   
*Add any further fields from structure WA_RK70P_T you want to display...

  WRITE:/ sy-uline.
* Aternatively use generic code to Write field values (and NAME) to screen report
  DO.
    ASSIGN COMPONENT sy-index OF STRUCTURE wa_RK70P_T TO <field>.
    IF sy-subrc <> 0. EXIT. ENDIF.
    WRITE:/ 'Field Value', <field>, sy-vline.
    gd_str = <field> .
    lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ).
    lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ).
    WRITE:/ 'Field Name', lv_fieldname.
  ENDDO.

  
*Redo loop but convert all fields from internal to out value  
LOOP AT IT_RK70P_T INTO WA_RK70P_T.


*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Convert all fields to display/output versions using conversion routines
  PERFORM convert_all_field_values CHANGING wa_EKKO.
	 
ENDLOOP.

  
*&---------------------------------------------------------------------*
*& Form convert_all_field_values
*&---------------------------------------------------------------------*
FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO.
DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RK70P_T_STR,
PMARK TYPE STRING,
POSNR TYPE STRING,
TYPPS TYPE STRING,
LTEXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_RK70P_T_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RK70P_T_STR-PMARK sy-vline
WA_RK70P_T_STR-POSNR sy-vline
WA_RK70P_T_STR-TYPPS sy-vline
WA_RK70P_T_STR-LTEXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.