ABAP Select data from SAP table RK70V into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP RK70V table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RK70V. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the RK70V table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_RK70V TYPE STANDARD TABLE OF RK70V, WA_RK70V TYPE RK70V, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <RK70V> TYPE RK70V. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_RK70V. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM RK70V INTO TABLE IT_RK70V. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM RK70V * INTO TABLE @DATA(IT_RK70V2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_RK70V INDEX 1 INTO DATA(WA_RK70V2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_RK70V ASSIGNING <RK70V>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<RK70V>-BUKRS = 1.
<RK70V>-RCOMP = 1.
<RK70V>-RLDNR = 1.
<RK70V>-RRCTY = 1.
<RK70V>-RVERS = 1.
ENDLOOP. LOOP AT IT_RK70V INTO WA_RK70V. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_RK70V-RYEAR, sy-vline,
WA_RK70V-RPLAN, sy-vline,
WA_RK70V-PLDAT, sy-vline,
WA_RK70V-WAERS, sy-vline,
WA_RK70V-RUNIT, sy-vline,
WA_RK70V-PEINH, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RK70V you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RK70V TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RK70V INTO WA_RK70V. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field RCOMP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RK70V-RCOMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RK70V-RCOMP.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field RLDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RK70V-RLDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RK70V-RLDNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field RVERS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RK70V-RVERS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RK70V-RVERS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit GJAHR, internal->external for field RYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_RK70V-RYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RK70V-RYEAR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field RUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RK70V-RUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RK70V-RUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RK70V_STR,
BUKRS TYPE STRING,
RCOMP TYPE STRING,
RLDNR TYPE STRING,
RRCTY TYPE STRING,
RVERS TYPE STRING,
RYEAR TYPE STRING,
RPLAN TYPE STRING,
PLDAT TYPE STRING,
WAERS TYPE STRING,
RUNIT TYPE STRING,
PEINH TYPE STRING,
TITLE TYPE STRING,
ACTION TYPE STRING,
SCALE TYPE STRING,
1DEC TYPE STRING,
2DEC TYPE STRING,
1UNIT TYPE STRING,
2UNIT TYPE STRING,
1UNIT_TYPE TYPE STRING,
2UNIT_TYPE TYPE STRING,
1TITLE TYPE STRING,
2TITLE TYPE STRING,
1SPRED TYPE STRING,
2SPRED TYPE STRING,
1EXP TYPE STRING,
2EXP TYPE STRING,
1POP TYPE STRING,
2POP TYPE STRING,
1PER TYPE STRING,
2PER TYPE STRING,
1YTD TYPE STRING,
2YTD TYPE STRING,
1TOT TYPE STRING,
2TOT TYPE STRING,
SET TYPE STRING,
FINDVALUE TYPE STRING,
FIELDTEXT TYPE STRING,
FIELDVALUE TYPE STRING,
START_SET TYPE STRING,
COUNT_SET TYPE STRING,
STEXT_FLD TYPE STRING,
START_SUM TYPE STRING,
COUNT_SUM TYPE STRING,
FGDISPLAY TYPE STRING,
RESOLVE TYPE STRING,
GPREIS TYPE STRING,END OF T_EKKO_STR. DATA: WA_RK70V_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RK70V_STR-BUKRS sy-vline
WA_RK70V_STR-RCOMP sy-vline
WA_RK70V_STR-RLDNR sy-vline
WA_RK70V_STR-RRCTY sy-vline
WA_RK70V_STR-RVERS sy-vline
WA_RK70V_STR-RYEAR sy-vline
WA_RK70V_STR-RPLAN sy-vline
WA_RK70V_STR-PLDAT sy-vline
WA_RK70V_STR-WAERS sy-vline
WA_RK70V_STR-RUNIT sy-vline
WA_RK70V_STR-PEINH sy-vline
WA_RK70V_STR-TITLE sy-vline
WA_RK70V_STR-ACTION sy-vline
WA_RK70V_STR-SCALE sy-vline
WA_RK70V_STR-1DEC sy-vline
WA_RK70V_STR-2DEC sy-vline
WA_RK70V_STR-1UNIT sy-vline
WA_RK70V_STR-2UNIT sy-vline
WA_RK70V_STR-1UNIT_TYPE sy-vline
WA_RK70V_STR-2UNIT_TYPE sy-vline
WA_RK70V_STR-1TITLE sy-vline
WA_RK70V_STR-2TITLE sy-vline
WA_RK70V_STR-1SPRED sy-vline
WA_RK70V_STR-2SPRED sy-vline
WA_RK70V_STR-1EXP sy-vline
WA_RK70V_STR-2EXP sy-vline
WA_RK70V_STR-1POP sy-vline
WA_RK70V_STR-2POP sy-vline
WA_RK70V_STR-1PER sy-vline
WA_RK70V_STR-2PER sy-vline
WA_RK70V_STR-1YTD sy-vline
WA_RK70V_STR-2YTD sy-vline
WA_RK70V_STR-1TOT sy-vline
WA_RK70V_STR-2TOT sy-vline
WA_RK70V_STR-SET sy-vline
WA_RK70V_STR-FINDVALUE sy-vline
WA_RK70V_STR-FIELDTEXT sy-vline
WA_RK70V_STR-FIELDVALUE sy-vline
WA_RK70V_STR-START_SET sy-vline
WA_RK70V_STR-COUNT_SET sy-vline
WA_RK70V_STR-STEXT_FLD sy-vline
WA_RK70V_STR-START_SUM sy-vline
WA_RK70V_STR-COUNT_SUM sy-vline
WA_RK70V_STR-FGDISPLAY sy-vline
WA_RK70V_STR-RESOLVE sy-vline
WA_RK70V_STR-GPREIS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.