ABAP Select data from SAP table RL031 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP RL031 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RL031. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the RL031 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_RL031 TYPE STANDARD TABLE OF RL031, WA_RL031 TYPE RL031, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <RL031> TYPE RL031. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_RL031. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM RL031 INTO TABLE IT_RL031. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM RL031 * INTO TABLE @DATA(IT_RL0312). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_RL031 INDEX 1 INTO DATA(WA_RL0312). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_RL031 ASSIGNING <RL031>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<RL031>-VBFA_VBELN = 1.
<RL031>-POSNN = 1.
<RL031>-LGMNG = 1.
<RL031>-LTAP_TANUM = 1.
<RL031>-LTAP_TAPOS = 1.
ENDLOOP. LOOP AT IT_RL031 INTO WA_RL031. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_RL031-LTAP_LETYP, sy-vline,
WA_RL031-VLENR, sy-vline,
WA_RL031-HOMVE, sy-vline,
WA_RL031-NISTM, sy-vline,
WA_RL031-ALTME, sy-vline,
WA_RL031-NISTA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RL031 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RL031 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RL031 INTO WA_RL031. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field VBFA_VBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RL031-VBFA_VBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RL031-VBFA_VBELN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit LENUM, internal->external for field VLENR CALL FUNCTION 'CONVERSION_EXIT_LENUM_OUTPUT' EXPORTING input = WA_RL031-VLENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RL031-VLENR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field ALTME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RL031-ALTME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RL031-ALTME.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RL031_STR,
VBFA_VBELN TYPE STRING,
POSNN TYPE STRING,
LGMNG TYPE STRING,
LTAP_TANUM TYPE STRING,
LTAP_TAPOS TYPE STRING,
LTAP_LETYP TYPE STRING,
VLENR TYPE STRING,
HOMVE TYPE STRING,
NISTM TYPE STRING,
ALTME TYPE STRING,
NISTA TYPE STRING,
VLPLA TYPE STRING,
VPPOS TYPE STRING,
VLPLA_MISCH TYPE STRING,
VLTYP TYPE STRING,
RFMNG TYPE STRING,END OF T_EKKO_STR. DATA: WA_RL031_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RL031_STR-VBFA_VBELN sy-vline
WA_RL031_STR-POSNN sy-vline
WA_RL031_STR-LGMNG sy-vline
WA_RL031_STR-LTAP_TANUM sy-vline
WA_RL031_STR-LTAP_TAPOS sy-vline
WA_RL031_STR-LTAP_LETYP sy-vline
WA_RL031_STR-VLENR sy-vline
WA_RL031_STR-HOMVE sy-vline
WA_RL031_STR-NISTM sy-vline
WA_RL031_STR-ALTME sy-vline
WA_RL031_STR-NISTA sy-vline
WA_RL031_STR-VLPLA sy-vline
WA_RL031_STR-VPPOS sy-vline
WA_RL031_STR-VLPLA_MISCH sy-vline
WA_RL031_STR-VLTYP sy-vline
WA_RL031_STR-RFMNG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.