ABAP Select data from SAP table RM06R into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RM06R table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RM06R. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RM06R table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RM06R TYPE STANDARD TABLE OF RM06R,
      WA_RM06R TYPE RM06R,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RM06R> TYPE RM06R.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RM06R.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RM06R
  INTO TABLE IT_RM06R.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RM06R
*  INTO TABLE @DATA(IT_RM06R2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RM06R INDEX 1 INTO DATA(WA_RM06R2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RM06R ASSIGNING <RM06R>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RM06R>-BISSL = 1.
<RM06R>-CPAGE = 1.
<RM06R>-KTEXT = 1.
<RM06R>-LINE1 = 1.
<RM06R>-LTEXT = 1.
ENDLOOP.

LOOP AT IT_RM06R INTO WA_RM06R.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RM06R-SRTFO, sy-vline,
WA_RM06R-STREP, sy-vline,
WA_RM06R-STRSB, sy-vline,
WA_RM06R-STRTD, sy-vline,
WA_RM06R-SUVAR, sy-vline,
WA_RM06R-TEXT1, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RM06R you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RM06R TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RM06R INTO WA_RM06R. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RM06R_STR,
BISSL TYPE STRING,
CPAGE TYPE STRING,
KTEXT TYPE STRING,
LINE1 TYPE STRING,
LTEXT TYPE STRING,
SRTFO TYPE STRING,
STREP TYPE STRING,
STRSB TYPE STRING,
STRTD TYPE STRING,
SUVAR TYPE STRING,
TEXT1 TYPE STRING,
TEXT2 TYPE STRING,
TEXT3 TYPE STRING,
TPAGE TYPE STRING,
VARNR TYPE STRING,
VONSL TYPE STRING,
VRBEZ TYPE STRING,
XDESC TYPE STRING,
XJA TYPE STRING,
XNEIN TYPE STRING,
XSFSW TYPE STRING,
XSTRG TYPE STRING,
XSUCH TYPE STRING,
XSUMA TYPE STRING,END OF T_EKKO_STR. DATA: WA_RM06R_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RM06R_STR-BISSL sy-vline
WA_RM06R_STR-CPAGE sy-vline
WA_RM06R_STR-KTEXT sy-vline
WA_RM06R_STR-LINE1 sy-vline
WA_RM06R_STR-LTEXT sy-vline
WA_RM06R_STR-SRTFO sy-vline
WA_RM06R_STR-STREP sy-vline
WA_RM06R_STR-STRSB sy-vline
WA_RM06R_STR-STRTD sy-vline
WA_RM06R_STR-SUVAR sy-vline
WA_RM06R_STR-TEXT1 sy-vline
WA_RM06R_STR-TEXT2 sy-vline
WA_RM06R_STR-TEXT3 sy-vline
WA_RM06R_STR-TPAGE sy-vline
WA_RM06R_STR-VARNR sy-vline
WA_RM06R_STR-VONSL sy-vline
WA_RM06R_STR-VRBEZ sy-vline
WA_RM06R_STR-XDESC sy-vline
WA_RM06R_STR-XJA sy-vline
WA_RM06R_STR-XNEIN sy-vline
WA_RM06R_STR-XSFSW sy-vline
WA_RM06R_STR-XSTRG sy-vline
WA_RM06R_STR-XSUCH sy-vline
WA_RM06R_STR-XSUMA sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.