ABAP Select data from SAP table RMAN_PRSP_OPER_ADD_FIELDS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RMAN_PRSP_OPER_ADD_FIELDS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RMAN_PRSP_OPER_ADD_FIELDS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RMAN_PRSP_OPER_ADD_FIELDS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RMAN_PRSP_OPER_ADD_FIELDS TYPE STANDARD TABLE OF RMAN_PRSP_OPER_ADD_FIELDS,
      WA_RMAN_PRSP_OPER_ADD_FIELDS TYPE RMAN_PRSP_OPER_ADD_FIELDS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RMAN_PRSP_OPER_ADD_FIELDS> TYPE RMAN_PRSP_OPER_ADD_FIELDS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RMAN_PRSP_OPER_ADD_FIELDS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RMAN_PRSP_OPER_ADD_FIELDS
  INTO TABLE IT_RMAN_PRSP_OPER_ADD_FIELDS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RMAN_PRSP_OPER_ADD_FIELDS
*  INTO TABLE @DATA(IT_RMAN_PRSP_OPER_ADD_FIELDS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RMAN_PRSP_OPER_ADD_FIELDS INDEX 1 INTO DATA(WA_RMAN_PRSP_OPER_ADD_FIELDS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RMAN_PRSP_OPER_ADD_FIELDS ASSIGNING <RMAN_PRSP_OPER_ADD_FIELDS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RMAN_PRSP_OPER_ADD_FIELDS>-ICON_STATUS = 1.
<RMAN_PRSP_OPER_ADD_FIELDS>-ICON_STATUS_REF = 1.
<RMAN_PRSP_OPER_ADD_FIELDS>-PROGR_ORD = 1.
<RMAN_PRSP_OPER_ADD_FIELDS>-PROGR_OPR = 1.
<RMAN_PRSP_OPER_ADD_FIELDS>-STATUS_FILTREF_OPER = 1.
ENDLOOP.

LOOP AT IT_RMAN_PRSP_OPER_ADD_FIELDS INTO WA_RMAN_PRSP_OPER_ADD_FIELDS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RMAN_PRSP_OPER_ADD_FIELDS-MATNR, sy-vline,
WA_RMAN_PRSP_OPER_ADD_FIELDS-CHARG, sy-vline,
WA_RMAN_PRSP_OPER_ADD_FIELDS-MATXT, sy-vline,
WA_RMAN_PRSP_OPER_ADD_FIELDS-ORD_PRIO, sy-vline,
WA_RMAN_PRSP_OPER_ADD_FIELDS-GAMNG, sy-vline,
WA_RMAN_PRSP_OPER_ADD_FIELDS-IGMNG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RMAN_PRSP_OPER_ADD_FIELDS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RMAN_PRSP_OPER_ADD_FIELDS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RMAN_PRSP_OPER_ADD_FIELDS INTO WA_RMAN_PRSP_OPER_ADD_FIELDS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_RMAN_PRSP_OPER_ADD_FIELDS-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RMAN_PRSP_OPER_ADD_FIELDS-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GMEIN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RMAN_PRSP_OPER_ADD_FIELDS-GMEIN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RMAN_PRSP_OPER_ADD_FIELDS-GMEIN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KDAUF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RMAN_PRSP_OPER_ADD_FIELDS-KDAUF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RMAN_PRSP_OPER_ADD_FIELDS-KDAUF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RMAN_PRSP_OPER_ADD_FIELDS-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RMAN_PRSP_OPER_ADD_FIELDS-KUNNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RMAN_PRSP_OPER_ADD_FIELDS_STR,
ICON_STATUS TYPE STRING,
ICON_STATUS_REF TYPE STRING,
PROGR_ORD TYPE STRING,
PROGR_OPR TYPE STRING,
STATUS_FILTREF_OPER TYPE STRING,
MATNR TYPE STRING,
CHARG TYPE STRING,
MATXT TYPE STRING,
ORD_PRIO TYPE STRING,
GAMNG TYPE STRING,
IGMNG TYPE STRING,
GMEIN TYPE STRING,
KDAUF TYPE STRING,
KDPOS TYPE STRING,
KUNNR TYPE STRING,
KUN_NAME TYPE STRING,
ECK_EN_D TYPE STRING,
ECK_EN_Z TYPE STRING,
ECK_ST_D TYPE STRING,
ECK_ST_Z TYPE STRING,
HEADER_OBJNR TYPE STRING,
RSNUM TYPE STRING,
AUART TYPE STRING,
FEVOR TYPE STRING,
DISPO TYPE STRING,
ARSNR TYPE STRING,
SOBKZ TYPE STRING,
LGORT TYPE STRING,
MAT_SHORTAGE TYPE STRING,
CAP_OVERLOAD TYPE STRING,
Q_PROBLEM TYPE STRING,
MACHINE_BREAKDOWN TYPE STRING,
PREDEC_PROBLEM TYPE STRING,
SUCC_PROBLEM TYPE STRING,
CUST_PROBLEM TYPE STRING,
HWAER TYPE STRING,
WERTN TYPE STRING,
WRTFX TYPE STRING,
WRTVR TYPE STRING,
PWERTN TYPE STRING,
GETRI TYPE STRING,
FTRMP TYPE STRING,
GWEMG TYPE STRING,
PWRTFX TYPE STRING,
PWRTVR TYPE STRING,
PLANT_TEXT TYPE STRING,
ACTUAL_START TYPE STRING,
ACTUAL_END TYPE STRING,
ORDER_STATUS TYPE STRING,
SCHED_FINISH_DATE TYPE STRING,
SCHED_START_DATE TYPE STRING,
STPRS TYPE STRING,
TOOLS_PROBLEM TYPE STRING,
SYS_STAT_DESC TYPE STRING,END OF T_EKKO_STR. DATA: WA_RMAN_PRSP_OPER_ADD_FIELDS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-ICON_STATUS sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-ICON_STATUS_REF sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-PROGR_ORD sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-PROGR_OPR sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-STATUS_FILTREF_OPER sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-MATNR sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-CHARG sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-MATXT sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-ORD_PRIO sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-GAMNG sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-IGMNG sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-GMEIN sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-KDAUF sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-KDPOS sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-KUNNR sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-KUN_NAME sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-ECK_EN_D sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-ECK_EN_Z sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-ECK_ST_D sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-ECK_ST_Z sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-HEADER_OBJNR sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-RSNUM sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-AUART sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-FEVOR sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-DISPO sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-ARSNR sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-SOBKZ sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-LGORT sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-MAT_SHORTAGE sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-CAP_OVERLOAD sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-Q_PROBLEM sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-MACHINE_BREAKDOWN sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-PREDEC_PROBLEM sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-SUCC_PROBLEM sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-CUST_PROBLEM sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-HWAER sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-WERTN sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-WRTFX sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-WRTVR sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-PWERTN sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-GETRI sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-FTRMP sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-GWEMG sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-PWRTFX sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-PWRTVR sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-PLANT_TEXT sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-ACTUAL_START sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-ACTUAL_END sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-ORDER_STATUS sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-SCHED_FINISH_DATE sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-SCHED_START_DATE sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-STPRS sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-TOOLS_PROBLEM sy-vline
WA_RMAN_PRSP_OPER_ADD_FIELDS_STR-SYS_STAT_DESC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.