ABAP Select data from SAP table RN1_DYNP_ME_TPN into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP RN1_DYNP_ME_TPN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RN1_DYNP_ME_TPN. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the RN1_DYNP_ME_TPN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_RN1_DYNP_ME_TPN TYPE STANDARD TABLE OF RN1_DYNP_ME_TPN, WA_RN1_DYNP_ME_TPN TYPE RN1_DYNP_ME_TPN, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <RN1_DYNP_ME_TPN> TYPE RN1_DYNP_ME_TPN. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_RN1_DYNP_ME_TPN. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM RN1_DYNP_ME_TPN INTO TABLE IT_RN1_DYNP_ME_TPN. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM RN1_DYNP_ME_TPN * INTO TABLE @DATA(IT_RN1_DYNP_ME_TPN2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_RN1_DYNP_ME_TPN INDEX 1 INTO DATA(WA_RN1_DYNP_ME_TPN2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_RN1_DYNP_ME_TPN ASSIGNING <RN1_DYNP_ME_TPN>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<RN1_DYNP_ME_TPN>-CONT_VOLUME = 1.
<RN1_DYNP_ME_TPN>-CONT_COND = 1.
<RN1_DYNP_ME_TPN>-INTERMITTENT = 1.
<RN1_DYNP_ME_TPN>-CALCUD = 1.
<RN1_DYNP_ME_TPN>-WEIGHT = 1.
ENDLOOP. LOOP AT IT_RN1_DYNP_ME_TPN INTO WA_RN1_DYNP_ME_TPN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_RN1_DYNP_ME_TPN-WEIGHTUNIT, sy-vline,
WA_RN1_DYNP_ME_TPN-HEIGHT, sy-vline,
WA_RN1_DYNP_ME_TPN-HEIGHTUNIT, sy-vline,
WA_RN1_DYNP_ME_TPN-TOINFUSE, sy-vline,
WA_RN1_DYNP_ME_TPN-INFUSEUNIT, sy-vline,
WA_RN1_DYNP_ME_TPN-INFOVER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RN1_DYNP_ME_TPN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RN1_DYNP_ME_TPN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RN1_DYNP_ME_TPN INTO WA_RN1_DYNP_ME_TPN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit MEQUA, internal->external for field WEIGHT CALL FUNCTION 'CONVERSION_EXIT_MEQUA_OUTPUT' EXPORTING input = WA_RN1_DYNP_ME_TPN-WEIGHT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1_DYNP_ME_TPN-WEIGHT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MEQUA, internal->external for field HEIGHT CALL FUNCTION 'CONVERSION_EXIT_MEQUA_OUTPUT' EXPORTING input = WA_RN1_DYNP_ME_TPN-HEIGHT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1_DYNP_ME_TPN-HEIGHT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ME12D, internal->external for field TOINFUSE CALL FUNCTION 'CONVERSION_EXIT_ME12D_OUTPUT' EXPORTING input = WA_RN1_DYNP_ME_TPN-TOINFUSE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1_DYNP_ME_TPN-TOINFUSE.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ME12D, internal->external for field INFOVER CALL FUNCTION 'CONVERSION_EXIT_ME12D_OUTPUT' EXPORTING input = WA_RN1_DYNP_ME_TPN-INFOVER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1_DYNP_ME_TPN-INFOVER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ME12D, internal->external for field INFRATE CALL FUNCTION 'CONVERSION_EXIT_ME12D_OUTPUT' EXPORTING input = WA_RN1_DYNP_ME_TPN-INFRATE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1_DYNP_ME_TPN-INFRATE.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MEQUA, internal->external for field RATETIME CALL FUNCTION 'CONVERSION_EXIT_MEQUA_OUTPUT' EXPORTING input = WA_RN1_DYNP_ME_TPN-RATETIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1_DYNP_ME_TPN-RATETIME.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ME12D, internal->external for field SOLRECAA CALL FUNCTION 'CONVERSION_EXIT_ME12D_OUTPUT' EXPORTING input = WA_RN1_DYNP_ME_TPN-SOLRECAA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1_DYNP_ME_TPN-SOLRECAA.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ME12D, internal->external for field TOTVOL CALL FUNCTION 'CONVERSION_EXIT_ME12D_OUTPUT' EXPORTING input = WA_RN1_DYNP_ME_TPN-TOTVOL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1_DYNP_ME_TPN-TOTVOL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RN1_DYNP_ME_TPN_STR,
CONT_VOLUME TYPE STRING,
CONT_COND TYPE STRING,
INTERMITTENT TYPE STRING,
CALCUD TYPE STRING,
WEIGHT TYPE STRING,
WEIGHTUNIT TYPE STRING,
HEIGHT TYPE STRING,
HEIGHTUNIT TYPE STRING,
TOINFUSE TYPE STRING,
INFUSEUNIT TYPE STRING,
INFOVER TYPE STRING,
OVERUNIT TYPE STRING,
INFRATE TYPE STRING,
RATEUNIT TYPE STRING,
RATETIME TYPE STRING,
RATETIMEUNIT TYPE STRING,
SOLUTION TYPE STRING,
SOLRECAA TYPE STRING,
SOLRECU TYPE STRING,
TOTVOL TYPE STRING,
TOTVOLU TYPE STRING,END OF T_EKKO_STR. DATA: WA_RN1_DYNP_ME_TPN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RN1_DYNP_ME_TPN_STR-CONT_VOLUME sy-vline
WA_RN1_DYNP_ME_TPN_STR-CONT_COND sy-vline
WA_RN1_DYNP_ME_TPN_STR-INTERMITTENT sy-vline
WA_RN1_DYNP_ME_TPN_STR-CALCUD sy-vline
WA_RN1_DYNP_ME_TPN_STR-WEIGHT sy-vline
WA_RN1_DYNP_ME_TPN_STR-WEIGHTUNIT sy-vline
WA_RN1_DYNP_ME_TPN_STR-HEIGHT sy-vline
WA_RN1_DYNP_ME_TPN_STR-HEIGHTUNIT sy-vline
WA_RN1_DYNP_ME_TPN_STR-TOINFUSE sy-vline
WA_RN1_DYNP_ME_TPN_STR-INFUSEUNIT sy-vline
WA_RN1_DYNP_ME_TPN_STR-INFOVER sy-vline
WA_RN1_DYNP_ME_TPN_STR-OVERUNIT sy-vline
WA_RN1_DYNP_ME_TPN_STR-INFRATE sy-vline
WA_RN1_DYNP_ME_TPN_STR-RATEUNIT sy-vline
WA_RN1_DYNP_ME_TPN_STR-RATETIME sy-vline
WA_RN1_DYNP_ME_TPN_STR-RATETIMEUNIT sy-vline
WA_RN1_DYNP_ME_TPN_STR-SOLUTION sy-vline
WA_RN1_DYNP_ME_TPN_STR-SOLRECAA sy-vline
WA_RN1_DYNP_ME_TPN_STR-SOLRECU sy-vline
WA_RN1_DYNP_ME_TPN_STR-TOTVOL sy-vline
WA_RN1_DYNP_ME_TPN_STR-TOTVOLU sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.