ABAP Select data from SAP table RN1ME_DYN_DOSECALC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RN1ME_DYN_DOSECALC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RN1ME_DYN_DOSECALC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RN1ME_DYN_DOSECALC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RN1ME_DYN_DOSECALC TYPE STANDARD TABLE OF RN1ME_DYN_DOSECALC,
      WA_RN1ME_DYN_DOSECALC TYPE RN1ME_DYN_DOSECALC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RN1ME_DYN_DOSECALC> TYPE RN1ME_DYN_DOSECALC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RN1ME_DYN_DOSECALC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RN1ME_DYN_DOSECALC
  INTO TABLE IT_RN1ME_DYN_DOSECALC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RN1ME_DYN_DOSECALC
*  INTO TABLE @DATA(IT_RN1ME_DYN_DOSECALC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RN1ME_DYN_DOSECALC INDEX 1 INTO DATA(WA_RN1ME_DYN_DOSECALC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RN1ME_DYN_DOSECALC ASSIGNING <RN1ME_DYN_DOSECALC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RN1ME_DYN_DOSECALC>-SELSTREN = 1.
<RN1ME_DYN_DOSECALC>-SELDAY = 1.
<RN1ME_DYN_DOSECALC>-SELQUAN = 1.
<RN1ME_DYN_DOSECALC>-STRGTH = 1.
<RN1ME_DYN_DOSECALC>-STRGTHU = 1.
ENDLOOP.

LOOP AT IT_RN1ME_DYN_DOSECALC INTO WA_RN1ME_DYN_DOSECALC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RN1ME_DYN_DOSECALC-STRGTHP, sy-vline,
WA_RN1ME_DYN_DOSECALC-STRGTHPU, sy-vline,
WA_RN1ME_DYN_DOSECALC-DRUGASTR, sy-vline,
WA_RN1ME_DYN_DOSECALC-DRUGASTRU, sy-vline,
WA_RN1ME_DYN_DOSECALC-CALCUD, sy-vline,
WA_RN1ME_DYN_DOSECALC-CMQUAN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RN1ME_DYN_DOSECALC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RN1ME_DYN_DOSECALC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RN1ME_DYN_DOSECALC INTO WA_RN1ME_DYN_DOSECALC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MEQUA, internal->external for field STRGTH CALL FUNCTION 'CONVERSION_EXIT_MEQUA_OUTPUT' EXPORTING input = WA_RN1ME_DYN_DOSECALC-STRGTH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1ME_DYN_DOSECALC-STRGTH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MEQUA, internal->external for field STRGTHP CALL FUNCTION 'CONVERSION_EXIT_MEQUA_OUTPUT' EXPORTING input = WA_RN1ME_DYN_DOSECALC-STRGTHP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1ME_DYN_DOSECALC-STRGTHP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MEQUA, internal->external for field DRUGASTR CALL FUNCTION 'CONVERSION_EXIT_MEQUA_OUTPUT' EXPORTING input = WA_RN1ME_DYN_DOSECALC-DRUGASTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1ME_DYN_DOSECALC-DRUGASTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MEQUA, internal->external for field CMQUAN CALL FUNCTION 'CONVERSION_EXIT_MEQUA_OUTPUT' EXPORTING input = WA_RN1ME_DYN_DOSECALC-CMQUAN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1ME_DYN_DOSECALC-CMQUAN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field CMU CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RN1ME_DYN_DOSECALC-CMU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1ME_DYN_DOSECALC-CMU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MEQUA, internal->external for field PATWGT CALL FUNCTION 'CONVERSION_EXIT_MEQUA_OUTPUT' EXPORTING input = WA_RN1ME_DYN_DOSECALC-PATWGT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1ME_DYN_DOSECALC-PATWGT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MEQUA, internal->external for field PATHGT CALL FUNCTION 'CONVERSION_EXIT_MEQUA_OUTPUT' EXPORTING input = WA_RN1ME_DYN_DOSECALC-PATHGT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1ME_DYN_DOSECALC-PATHGT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MEQUA, internal->external for field DAYQUAN CALL FUNCTION 'CONVERSION_EXIT_MEQUA_OUTPUT' EXPORTING input = WA_RN1ME_DYN_DOSECALC-DAYQUAN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1ME_DYN_DOSECALC-DAYQUAN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MEQUA, internal->external for field TOTQUAN CALL FUNCTION 'CONVERSION_EXIT_MEQUA_OUTPUT' EXPORTING input = WA_RN1ME_DYN_DOSECALC-TOTQUAN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1ME_DYN_DOSECALC-TOTQUAN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ZNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RN1ME_DYN_DOSECALC-ZNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1ME_DYN_DOSECALC-ZNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MEQUA, internal->external for field ORDUR CALL FUNCTION 'CONVERSION_EXIT_MEQUA_OUTPUT' EXPORTING input = WA_RN1ME_DYN_DOSECALC-ORDUR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1ME_DYN_DOSECALC-ORDUR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MEQUA, internal->external for field DOSE CALL FUNCTION 'CONVERSION_EXIT_MEQUA_OUTPUT' EXPORTING input = WA_RN1ME_DYN_DOSECALC-DOSE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1ME_DYN_DOSECALC-DOSE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RN1ME_DYN_DOSECALC_STR,
SELSTREN TYPE STRING,
SELDAY TYPE STRING,
SELQUAN TYPE STRING,
STRGTH TYPE STRING,
STRGTHU TYPE STRING,
STRGTHP TYPE STRING,
STRGTHPU TYPE STRING,
DRUGASTR TYPE STRING,
DRUGASTRU TYPE STRING,
CALCUD TYPE STRING,
CMQUAN TYPE STRING,
CMU TYPE STRING,
PATWGT TYPE STRING,
PATWGTU TYPE STRING,
PATHGT TYPE STRING,
PATHGTU TYPE STRING,
DAYQUAN TYPE STRING,
DAYQUANU TYPE STRING,
TOTQUAN TYPE STRING,
TOTQUANUOM TYPE STRING,
ZNR TYPE STRING,
FREQ_ICON TYPE STRING,
ORDUR TYPE STRING,
ORDURU TYPE STRING,
DOSE TYPE STRING,
DOSEU TYPE STRING,
MAXDEN TYPE STRING,
BSA TYPE STRING,
COMP_USED TYPE STRING,
DOSAGE_INFORMATION TYPE STRING,
DOSDEF TYPE STRING,END OF T_EKKO_STR. DATA: WA_RN1ME_DYN_DOSECALC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RN1ME_DYN_DOSECALC_STR-SELSTREN sy-vline
WA_RN1ME_DYN_DOSECALC_STR-SELDAY sy-vline
WA_RN1ME_DYN_DOSECALC_STR-SELQUAN sy-vline
WA_RN1ME_DYN_DOSECALC_STR-STRGTH sy-vline
WA_RN1ME_DYN_DOSECALC_STR-STRGTHU sy-vline
WA_RN1ME_DYN_DOSECALC_STR-STRGTHP sy-vline
WA_RN1ME_DYN_DOSECALC_STR-STRGTHPU sy-vline
WA_RN1ME_DYN_DOSECALC_STR-DRUGASTR sy-vline
WA_RN1ME_DYN_DOSECALC_STR-DRUGASTRU sy-vline
WA_RN1ME_DYN_DOSECALC_STR-CALCUD sy-vline
WA_RN1ME_DYN_DOSECALC_STR-CMQUAN sy-vline
WA_RN1ME_DYN_DOSECALC_STR-CMU sy-vline
WA_RN1ME_DYN_DOSECALC_STR-PATWGT sy-vline
WA_RN1ME_DYN_DOSECALC_STR-PATWGTU sy-vline
WA_RN1ME_DYN_DOSECALC_STR-PATHGT sy-vline
WA_RN1ME_DYN_DOSECALC_STR-PATHGTU sy-vline
WA_RN1ME_DYN_DOSECALC_STR-DAYQUAN sy-vline
WA_RN1ME_DYN_DOSECALC_STR-DAYQUANU sy-vline
WA_RN1ME_DYN_DOSECALC_STR-TOTQUAN sy-vline
WA_RN1ME_DYN_DOSECALC_STR-TOTQUANUOM sy-vline
WA_RN1ME_DYN_DOSECALC_STR-ZNR sy-vline
WA_RN1ME_DYN_DOSECALC_STR-FREQ_ICON sy-vline
WA_RN1ME_DYN_DOSECALC_STR-ORDUR sy-vline
WA_RN1ME_DYN_DOSECALC_STR-ORDURU sy-vline
WA_RN1ME_DYN_DOSECALC_STR-DOSE sy-vline
WA_RN1ME_DYN_DOSECALC_STR-DOSEU sy-vline
WA_RN1ME_DYN_DOSECALC_STR-MAXDEN sy-vline
WA_RN1ME_DYN_DOSECALC_STR-BSA sy-vline
WA_RN1ME_DYN_DOSECALC_STR-COMP_USED sy-vline
WA_RN1ME_DYN_DOSECALC_STR-DOSAGE_INFORMATION sy-vline
WA_RN1ME_DYN_DOSECALC_STR-DOSDEF sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.