Below is a number of ABAP code snippets to demonstrate how to select data from SAP RN1ME_LOCK table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RN1ME_LOCK. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the RN1ME_LOCK table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_RN1ME_LOCK TYPE STANDARD TABLE OF RN1ME_LOCK, WA_RN1ME_LOCK TYPE RN1ME_LOCK, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <RN1ME_LOCK> TYPE RN1ME_LOCK. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_RN1ME_LOCK. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM RN1ME_LOCK INTO TABLE IT_RN1ME_LOCK. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM RN1ME_LOCK * INTO TABLE @DATA(IT_RN1ME_LOCK2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_RN1ME_LOCK INDEX 1 INTO DATA(WA_RN1ME_LOCK2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_RN1ME_LOCK ASSIGNING <RN1ME_LOCK>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<RN1ME_LOCK>-LOCK_KEY = 1.
<RN1ME_LOCK>-MASTER_LOCK_KEY = 1.
<RN1ME_LOCK>-ENQUEUE = 1.
<RN1ME_LOCK>-ELEMENT = 1.
<RN1ME_LOCK>-MANDT = 1.
ENDLOOP. LOOP AT IT_RN1ME_LOCK INTO WA_RN1ME_LOCK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_RN1ME_LOCK-PATNR, sy-vline,
WA_RN1ME_LOCK-ARGUMENT1, sy-vline,
WA_RN1ME_LOCK-ARGUMENT2, sy-vline,
WA_RN1ME_LOCK-R_OBJ, sy-vline,
WA_RN1ME_LOCK-ACTION, sy-vline,
WA_RN1ME_LOCK-EINRI, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RN1ME_LOCK you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RN1ME_LOCK TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RN1ME_LOCK INTO WA_RN1ME_LOCK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field PATNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RN1ME_LOCK-PATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1ME_LOCK-PATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field EINRI CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RN1ME_LOCK-EINRI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1ME_LOCK-EINRI.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field FALNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RN1ME_LOCK-FALNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1ME_LOCK-FALNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RN1ME_LOCK_STR,
LOCK_KEY TYPE STRING,
MASTER_LOCK_KEY TYPE STRING,
ENQUEUE TYPE STRING,
ELEMENT TYPE STRING,
MANDT TYPE STRING,
PATNR TYPE STRING,
ARGUMENT1 TYPE STRING,
ARGUMENT2 TYPE STRING,
R_OBJ TYPE STRING,
ACTION TYPE STRING,
EINRI TYPE STRING,
FALNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_RN1ME_LOCK_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RN1ME_LOCK_STR-LOCK_KEY sy-vline
WA_RN1ME_LOCK_STR-MASTER_LOCK_KEY sy-vline
WA_RN1ME_LOCK_STR-ENQUEUE sy-vline
WA_RN1ME_LOCK_STR-ELEMENT sy-vline
WA_RN1ME_LOCK_STR-MANDT sy-vline
WA_RN1ME_LOCK_STR-PATNR sy-vline
WA_RN1ME_LOCK_STR-ARGUMENT1 sy-vline
WA_RN1ME_LOCK_STR-ARGUMENT2 sy-vline
WA_RN1ME_LOCK_STR-R_OBJ sy-vline
WA_RN1ME_LOCK_STR-ACTION sy-vline
WA_RN1ME_LOCK_STR-EINRI sy-vline
WA_RN1ME_LOCK_STR-FALNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.