ABAP Select data from SAP table RN2DWSWL_WORK_DETAIL_SCR into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP RN2DWSWL_WORK_DETAIL_SCR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RN2DWSWL_WORK_DETAIL_SCR. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the RN2DWSWL_WORK_DETAIL_SCR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_RN2DWSWL_WORK_DETAIL_SCR TYPE STANDARD TABLE OF RN2DWSWL_WORK_DETAIL_SCR, WA_RN2DWSWL_WORK_DETAIL_SCR TYPE RN2DWSWL_WORK_DETAIL_SCR, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <RN2DWSWL_WORK_DETAIL_SCR> TYPE RN2DWSWL_WORK_DETAIL_SCR. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_RN2DWSWL_WORK_DETAIL_SCR. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM RN2DWSWL_WORK_DETAIL_SCR INTO TABLE IT_RN2DWSWL_WORK_DETAIL_SCR. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM RN2DWSWL_WORK_DETAIL_SCR * INTO TABLE @DATA(IT_RN2DWSWL_WORK_DETAIL_SCR2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_RN2DWSWL_WORK_DETAIL_SCR INDEX 1 INTO DATA(WA_RN2DWSWL_WORK_DETAIL_SCR2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_RN2DWSWL_WORK_DETAIL_SCR ASSIGNING <RN2DWSWL_WORK_DETAIL_SCR>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<RN2DWSWL_WORK_DETAIL_SCR>-PATNR = 1.
<RN2DWSWL_WORK_DETAIL_SCR>-PATIENT_NAME = 1.
<RN2DWSWL_WORK_DETAIL_SCR>-NAME_AGE_SEX = 1.
<RN2DWSWL_WORK_DETAIL_SCR>-AREA = 1.
<RN2DWSWL_WORK_DETAIL_SCR>-AREA_NAME = 1.
ENDLOOP. LOOP AT IT_RN2DWSWL_WORK_DETAIL_SCR INTO WA_RN2DWSWL_WORK_DETAIL_SCR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_RN2DWSWL_WORK_DETAIL_SCR-WORK_ID, sy-vline,
WA_RN2DWSWL_WORK_DETAIL_SCR-WORK_NAME, sy-vline,
WA_RN2DWSWL_WORK_DETAIL_SCR-WORK_STATE, sy-vline,
WA_RN2DWSWL_WORK_DETAIL_SCR-WORK_STATE_TXT, sy-vline,
WA_RN2DWSWL_WORK_DETAIL_SCR-SHORT_CODE, sy-vline,
WA_RN2DWSWL_WORK_DETAIL_SCR-WORK_STARTED_ON, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RN2DWSWL_WORK_DETAIL_SCR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RN2DWSWL_WORK_DETAIL_SCR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RN2DWSWL_WORK_DETAIL_SCR INTO WA_RN2DWSWL_WORK_DETAIL_SCR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field PATNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RN2DWSWL_WORK_DETAIL_SCR-PATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN2DWSWL_WORK_DETAIL_SCR-PATNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RN2DWSWL_WORK_DETAIL_SCR_STR,
PATNR TYPE STRING,
PATIENT_NAME TYPE STRING,
NAME_AGE_SEX TYPE STRING,
AREA TYPE STRING,
AREA_NAME TYPE STRING,
WORK_ID TYPE STRING,
WORK_NAME TYPE STRING,
WORK_STATE TYPE STRING,
WORK_STATE_TXT TYPE STRING,
SHORT_CODE TYPE STRING,
WORK_STARTED_ON TYPE STRING,
WORK_STARTED_AT TYPE STRING,
WORK_STARTED_BY TYPE STRING,
WORK_CLOSED_ON TYPE STRING,
WORK_CLOSED_AT TYPE STRING,
WORK_CLOSED_BY TYPE STRING,
AUTO_CLOSE TYPE STRING,
INFO_ID TYPE STRING,
INFO_SHORT_CODE TYPE STRING,
INFO_NAME TYPE STRING,
HAS_NOTE_TXT TYPE STRING,
CONTACT_PERSON TYPE STRING,
CONTACT_PHONE TYPE STRING,
CONTACT_EMAIL TYPE STRING,
FUN_VARIANT TYPE STRING,
WORK_OFFSET TYPE STRING,
WORK_OFFSET_TXT TYPE STRING,
ACCESS_OFFSET TYPE STRING,
CLOSE_OFFSET TYPE STRING,
INSDATE TYPE STRING,
INSUSER TYPE STRING,
UPDDATE TYPE STRING,
UPDUSER TYPE STRING,
WORK_PLAN_DATE TYPE STRING,
TASK_CREATED TYPE STRING,
CLIO_CONFIG_ID TYPE STRING,
CHART_CONFIG_ID TYPE STRING,
CLIO_MODE TYPE STRING,
WORK_STATE_ICON TYPE STRING,
WORK_STATE_ICONNAME TYPE STRING,
NOTE_ICON TYPE STRING,
NOTE_ICONNAME TYPE STRING,END OF T_EKKO_STR. DATA: WA_RN2DWSWL_WORK_DETAIL_SCR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-PATNR sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-PATIENT_NAME sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-NAME_AGE_SEX sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-AREA sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-AREA_NAME sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-WORK_ID sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-WORK_NAME sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-WORK_STATE sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-WORK_STATE_TXT sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-SHORT_CODE sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-WORK_STARTED_ON sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-WORK_STARTED_AT sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-WORK_STARTED_BY sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-WORK_CLOSED_ON sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-WORK_CLOSED_AT sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-WORK_CLOSED_BY sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-AUTO_CLOSE sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-INFO_ID sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-INFO_SHORT_CODE sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-INFO_NAME sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-HAS_NOTE_TXT sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-CONTACT_PERSON sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-CONTACT_PHONE sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-CONTACT_EMAIL sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-FUN_VARIANT sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-WORK_OFFSET sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-WORK_OFFSET_TXT sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-ACCESS_OFFSET sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-CLOSE_OFFSET sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-INSDATE sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-INSUSER sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-UPDDATE sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-UPDUSER sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-WORK_PLAN_DATE sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-TASK_CREATED sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-CLIO_CONFIG_ID sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-CHART_CONFIG_ID sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-CLIO_MODE sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-WORK_STATE_ICON sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-WORK_STATE_ICONNAME sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-NOTE_ICON sy-vline
WA_RN2DWSWL_WORK_DETAIL_SCR_STR-NOTE_ICONNAME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.