ABAP Select data from SAP table RODPSODPEHEAD into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP RODPSODPEHEAD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RODPSODPEHEAD. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the RODPSODPEHEAD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_RODPSODPEHEAD TYPE STANDARD TABLE OF RODPSODPEHEAD, WA_RODPSODPEHEAD TYPE RODPSODPEHEAD, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <RODPSODPEHEAD> TYPE RODPSODPEHEAD. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_RODPSODPEHEAD. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM RODPSODPEHEAD INTO TABLE IT_RODPSODPEHEAD. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM RODPSODPEHEAD * INTO TABLE @DATA(IT_RODPSODPEHEAD2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_RODPSODPEHEAD INDEX 1 INTO DATA(WA_RODPSODPEHEAD2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_RODPSODPEHEAD ASSIGNING <RODPSODPEHEAD>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<RODPSODPEHEAD>-ODP_ID = 1.
<RODPSODPEHEAD>-SEMANTICS = 1.
<RODPSODPEHEAD>-OBJECT_TYPE_NAME = 1.
<RODPSODPEHEAD>-SYSREL = 1.
<RODPSODPEHEAD>-CONNECTOR = 1.
ENDLOOP. LOOP AT IT_RODPSODPEHEAD INTO WA_RODPSODPEHEAD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_RODPSODPEHEAD-APPL_COMP, sy-vline,
WA_RODPSODPEHEAD-TIMESTAMP, sy-vline,
WA_RODPSODPEHEAD-NODE_NAME, sy-vline,
WA_RODPSODPEHEAD-TIMESTAMP_ACTIVE, sy-vline,
WA_RODPSODPEHEAD-BACKEND_NAME, sy-vline,
WA_RODPSODPEHEAD-ERROR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RODPSODPEHEAD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RODPSODPEHEAD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RODPSODPEHEAD INTO WA_RODPSODPEHEAD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RODPSODPEHEAD_STR,
ODP_ID TYPE STRING,
SEMANTICS TYPE STRING,
OBJECT_TYPE_NAME TYPE STRING,
SYSREL TYPE STRING,
CONNECTOR TYPE STRING,
APPL_COMP TYPE STRING,
TIMESTAMP TYPE STRING,
NODE_NAME TYPE STRING,
TIMESTAMP_ACTIVE TYPE STRING,
BACKEND_NAME TYPE STRING,
ERROR TYPE STRING,
BACKEND_TYPE TYPE STRING,
BACKEND_TSTPDAT TYPE STRING,
BACKEND_TSTPTIM TYPE STRING,
MODEL_TYPE TYPE STRING,
ORG_C TYPE STRING,
ORG_AREA TYPE STRING,
CHANGED_BY TYPE STRING,
CALLER TYPE STRING,
GENERATOR TYPE STRING,END OF T_EKKO_STR. DATA: WA_RODPSODPEHEAD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RODPSODPEHEAD_STR-ODP_ID sy-vline
WA_RODPSODPEHEAD_STR-SEMANTICS sy-vline
WA_RODPSODPEHEAD_STR-OBJECT_TYPE_NAME sy-vline
WA_RODPSODPEHEAD_STR-SYSREL sy-vline
WA_RODPSODPEHEAD_STR-CONNECTOR sy-vline
WA_RODPSODPEHEAD_STR-APPL_COMP sy-vline
WA_RODPSODPEHEAD_STR-TIMESTAMP sy-vline
WA_RODPSODPEHEAD_STR-NODE_NAME sy-vline
WA_RODPSODPEHEAD_STR-TIMESTAMP_ACTIVE sy-vline
WA_RODPSODPEHEAD_STR-BACKEND_NAME sy-vline
WA_RODPSODPEHEAD_STR-ERROR sy-vline
WA_RODPSODPEHEAD_STR-BACKEND_TYPE sy-vline
WA_RODPSODPEHEAD_STR-BACKEND_TSTPDAT sy-vline
WA_RODPSODPEHEAD_STR-BACKEND_TSTPTIM sy-vline
WA_RODPSODPEHEAD_STR-MODEL_TYPE sy-vline
WA_RODPSODPEHEAD_STR-ORG_C sy-vline
WA_RODPSODPEHEAD_STR-ORG_AREA sy-vline
WA_RODPSODPEHEAD_STR-CHANGED_BY sy-vline
WA_RODPSODPEHEAD_STR-CALLER sy-vline
WA_RODPSODPEHEAD_STR-GENERATOR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.