ABAP Select data from SAP table ROIJNOMREFERENCEITEM into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP ROIJNOMREFERENCEITEM table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ROIJNOMREFERENCEITEM. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the ROIJNOMREFERENCEITEM table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_ROIJNOMREFERENCEITEM TYPE STANDARD TABLE OF ROIJNOMREFERENCEITEM, WA_ROIJNOMREFERENCEITEM TYPE ROIJNOMREFERENCEITEM, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <ROIJNOMREFERENCEITEM> TYPE ROIJNOMREFERENCEITEM. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_ROIJNOMREFERENCEITEM. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM ROIJNOMREFERENCEITEM INTO TABLE IT_ROIJNOMREFERENCEITEM. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM ROIJNOMREFERENCEITEM * INTO TABLE @DATA(IT_ROIJNOMREFERENCEITEM2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_ROIJNOMREFERENCEITEM INDEX 1 INTO DATA(WA_ROIJNOMREFERENCEITEM2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_ROIJNOMREFERENCEITEM ASSIGNING <ROIJNOMREFERENCEITEM>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<ROIJNOMREFERENCEITEM>-DOCIND = 1.
<ROIJNOMREFERENCEITEM>-DOCNR = 1.
<ROIJNOMREFERENCEITEM>-DOCITM = 1.
<ROIJNOMREFERENCEITEM>-SCHED_TST_FROM = 1.
<ROIJNOMREFERENCEITEM>-SCHED_TST_TO = 1.
ENDLOOP. LOOP AT IT_ROIJNOMREFERENCEITEM INTO WA_ROIJNOMREFERENCEITEM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_ROIJNOMREFERENCEITEM-LOCID, sy-vline,
WA_ROIJNOMREFERENCEITEM-S_MATNR_I, sy-vline,
WA_ROIJNOMREFERENCEITEM-MENGE, sy-vline,
WA_ROIJNOMREFERENCEITEM-UNIT_I, sy-vline,
WA_ROIJNOMREFERENCEITEM-MENGE_R, sy-vline,
WA_ROIJNOMREFERENCEITEM-UNIT_I_T, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ROIJNOMREFERENCEITEM you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ROIJNOMREFERENCEITEM TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ROIJNOMREFERENCEITEM INTO WA_ROIJNOMREFERENCEITEM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field DOCNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIJNOMREFERENCEITEM-DOCNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIJNOMREFERENCEITEM-DOCNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field S_MATNR_I CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_ROIJNOMREFERENCEITEM-S_MATNR_I IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIJNOMREFERENCEITEM-S_MATNR_I.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UNIT_I CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROIJNOMREFERENCEITEM-UNIT_I IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIJNOMREFERENCEITEM-UNIT_I.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UNIT_I_T CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROIJNOMREFERENCEITEM-UNIT_I_T IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIJNOMREFERENCEITEM-UNIT_I_T.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ROIJNOMREFERENCEITEM_STR,
DOCIND TYPE STRING,
DOCNR TYPE STRING,
DOCITM TYPE STRING,
SCHED_TST_FROM TYPE STRING,
SCHED_TST_TO TYPE STRING,
LOCID TYPE STRING,
S_MATNR_I TYPE STRING,
MENGE TYPE STRING,
UNIT_I TYPE STRING,
MENGE_R TYPE STRING,
UNIT_I_T TYPE STRING,END OF T_EKKO_STR. DATA: WA_ROIJNOMREFERENCEITEM_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ROIJNOMREFERENCEITEM_STR-DOCIND sy-vline
WA_ROIJNOMREFERENCEITEM_STR-DOCNR sy-vline
WA_ROIJNOMREFERENCEITEM_STR-DOCITM sy-vline
WA_ROIJNOMREFERENCEITEM_STR-SCHED_TST_FROM sy-vline
WA_ROIJNOMREFERENCEITEM_STR-SCHED_TST_TO sy-vline
WA_ROIJNOMREFERENCEITEM_STR-LOCID sy-vline
WA_ROIJNOMREFERENCEITEM_STR-S_MATNR_I sy-vline
WA_ROIJNOMREFERENCEITEM_STR-MENGE sy-vline
WA_ROIJNOMREFERENCEITEM_STR-UNIT_I sy-vline
WA_ROIJNOMREFERENCEITEM_STR-MENGE_R sy-vline
WA_ROIJNOMREFERENCEITEM_STR-UNIT_I_T sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.