ABAP Select data from SAP table ROIJTHPUTFC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ROIJTHPUTFC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ROIJTHPUTFC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ROIJTHPUTFC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ROIJTHPUTFC TYPE STANDARD TABLE OF ROIJTHPUTFC,
      WA_ROIJTHPUTFC TYPE ROIJTHPUTFC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ROIJTHPUTFC> TYPE ROIJTHPUTFC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ROIJTHPUTFC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ROIJTHPUTFC
  INTO TABLE IT_ROIJTHPUTFC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ROIJTHPUTFC
*  INTO TABLE @DATA(IT_ROIJTHPUTFC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ROIJTHPUTFC INDEX 1 INTO DATA(WA_ROIJTHPUTFC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ROIJTHPUTFC ASSIGNING <ROIJTHPUTFC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ROIJTHPUTFC>-MANDT = 1.
<ROIJTHPUTFC>-LOCID = 1.
<ROIJTHPUTFC>-SOCNR = 1.
<ROIJTHPUTFC>-MATNR = 1.
<ROIJTHPUTFC>-CHARG = 1.
ENDLOOP.

LOOP AT IT_ROIJTHPUTFC INTO WA_ROIJTHPUTFC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ROIJTHPUTFC-DATUM, sy-vline,
WA_ROIJTHPUTFC-VKTRA, sy-vline,
WA_ROIJTHPUTFC-FCTYPE, sy-vline,
WA_ROIJTHPUTFC-CUFCTYPE, sy-vline,
WA_ROIJTHPUTFC-THPFCIND, sy-vline,
WA_ROIJTHPUTFC-THPUT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ROIJTHPUTFC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ROIJTHPUTFC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ROIJTHPUTFC INTO WA_ROIJTHPUTFC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_ROIJTHPUTFC-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIJTHPUTFC-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field THPUTUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROIJTHPUTFC-THPUTUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIJTHPUTFC-THPUTUOM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ROIJTHPUTFC_STR,
MANDT TYPE STRING,
LOCID TYPE STRING,
SOCNR TYPE STRING,
MATNR TYPE STRING,
CHARG TYPE STRING,
DATUM TYPE STRING,
VKTRA TYPE STRING,
FCTYPE TYPE STRING,
CUFCTYPE TYPE STRING,
THPFCIND TYPE STRING,
THPUT TYPE STRING,
THPUTUOM TYPE STRING,
ERDAT TYPE STRING,
ERZEIT TYPE STRING,
ERNAM TYPE STRING,
AEDAT TYPE STRING,
AEZEIT TYPE STRING,
AENAM TYPE STRING,
BLOIND TYPE STRING,
DELIND TYPE STRING,
TKTSELECT TYPE STRING,
UPD_FLAG TYPE STRING,END OF T_EKKO_STR. DATA: WA_ROIJTHPUTFC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ROIJTHPUTFC_STR-MANDT sy-vline
WA_ROIJTHPUTFC_STR-LOCID sy-vline
WA_ROIJTHPUTFC_STR-SOCNR sy-vline
WA_ROIJTHPUTFC_STR-MATNR sy-vline
WA_ROIJTHPUTFC_STR-CHARG sy-vline
WA_ROIJTHPUTFC_STR-DATUM sy-vline
WA_ROIJTHPUTFC_STR-VKTRA sy-vline
WA_ROIJTHPUTFC_STR-FCTYPE sy-vline
WA_ROIJTHPUTFC_STR-CUFCTYPE sy-vline
WA_ROIJTHPUTFC_STR-THPFCIND sy-vline
WA_ROIJTHPUTFC_STR-THPUT sy-vline
WA_ROIJTHPUTFC_STR-THPUTUOM sy-vline
WA_ROIJTHPUTFC_STR-ERDAT sy-vline
WA_ROIJTHPUTFC_STR-ERZEIT sy-vline
WA_ROIJTHPUTFC_STR-ERNAM sy-vline
WA_ROIJTHPUTFC_STR-AEDAT sy-vline
WA_ROIJTHPUTFC_STR-AEZEIT sy-vline
WA_ROIJTHPUTFC_STR-AENAM sy-vline
WA_ROIJTHPUTFC_STR-BLOIND sy-vline
WA_ROIJTHPUTFC_STR-DELIND sy-vline
WA_ROIJTHPUTFC_STR-TKTSELECT sy-vline
WA_ROIJTHPUTFC_STR-UPD_FLAG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.