ABAP Select data from SAP table ROIO_RT_ESLL_LIST into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ROIO_RT_ESLL_LIST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ROIO_RT_ESLL_LIST. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ROIO_RT_ESLL_LIST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ROIO_RT_ESLL_LIST TYPE STANDARD TABLE OF ROIO_RT_ESLL_LIST,
      WA_ROIO_RT_ESLL_LIST TYPE ROIO_RT_ESLL_LIST,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ROIO_RT_ESLL_LIST> TYPE ROIO_RT_ESLL_LIST.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ROIO_RT_ESLL_LIST.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ROIO_RT_ESLL_LIST
  INTO TABLE IT_ROIO_RT_ESLL_LIST.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ROIO_RT_ESLL_LIST
*  INTO TABLE @DATA(IT_ROIO_RT_ESLL_LIST2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ROIO_RT_ESLL_LIST INDEX 1 INTO DATA(WA_ROIO_RT_ESLL_LIST2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ROIO_RT_ESLL_LIST ASSIGNING <ROIO_RT_ESLL_LIST>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ROIO_RT_ESLL_LIST>-AUFNR = 1.
<ROIO_RT_ESLL_LIST>-AUART = 1.
<ROIO_RT_ESLL_LIST>-AUTYP = 1.
<ROIO_RT_ESLL_LIST>-AUFPL = 1.
<ROIO_RT_ESLL_LIST>-APLZL = 1.
ENDLOOP.

LOOP AT IT_ROIO_RT_ESLL_LIST INTO WA_ROIO_RT_ESLL_LIST.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ROIO_RT_ESLL_LIST-VORNR, sy-vline,
WA_ROIO_RT_ESLL_LIST-REFNR, sy-vline,
WA_ROIO_RT_ESLL_LIST-ERNAM, sy-vline,
WA_ROIO_RT_ESLL_LIST-ERDAT, sy-vline,
WA_ROIO_RT_ESLL_LIST-AENAM, sy-vline,
WA_ROIO_RT_ESLL_LIST-AEDAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ROIO_RT_ESLL_LIST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ROIO_RT_ESLL_LIST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ROIO_RT_ESLL_LIST INTO WA_ROIO_RT_ESLL_LIST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIO_RT_ESLL_LIST-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIO_RT_ESLL_LIST-AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field VORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_ROIO_RT_ESLL_LIST-VORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIO_RT_ESLL_LIST-VORNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field REFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIO_RT_ESLL_LIST-REFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIO_RT_ESLL_LIST-REFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOSTV CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIO_RT_ESLL_LIST-KOSTV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIO_RT_ESLL_LIST-KOSTV.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIO_RT_ESLL_LIST-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIO_RT_ESLL_LIST-PRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field PSPEL CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_ROIO_RT_ESLL_LIST-PSPEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIO_RT_ESLL_LIST-PSPEL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SRVPOS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIO_RT_ESLL_LIST-SRVPOS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIO_RT_ESLL_LIST-SRVPOS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field OIO_MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_ROIO_RT_ESLL_LIST-OIO_MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIO_RT_ESLL_LIST-OIO_MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field OIO_MBMEI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROIO_RT_ESLL_LIST-OIO_MBMEI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIO_RT_ESLL_LIST-OIO_MBMEI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field OIO_MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROIO_RT_ESLL_LIST-OIO_MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIO_RT_ESLL_LIST-OIO_MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field OIO_ACT_MBMEI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROIO_RT_ESLL_LIST-OIO_ACT_MBMEI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIO_RT_ESLL_LIST-OIO_ACT_MBMEI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field OIO_ACT_DMBMEI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROIO_RT_ESLL_LIST-OIO_ACT_DMBMEI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIO_RT_ESLL_LIST-OIO_ACT_DMBMEI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DOCNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIO_RT_ESLL_LIST-DOCNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIO_RT_ESLL_LIST-DOCNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ROIO_RT_ESLL_LIST_STR,
AUFNR TYPE STRING,
AUART TYPE STRING,
AUTYP TYPE STRING,
AUFPL TYPE STRING,
APLZL TYPE STRING,
VORNR TYPE STRING,
REFNR TYPE STRING,
ERNAM TYPE STRING,
ERDAT TYPE STRING,
AENAM TYPE STRING,
AEDAT TYPE STRING,
KTEXT TYPE STRING,
BUKRS TYPE STRING,
KOKRS TYPE STRING,
CCKEY TYPE STRING,
KOSTV TYPE STRING,
PRCTR TYPE STRING,
PSPEL TYPE STRING,
WERKS TYPE STRING,
PACKNO TYPE STRING,
INTROW TYPE STRING,
EXTROW TYPE STRING,
SRVPOS TYPE STRING,
KTEXT1 TYPE STRING,
OIO_XRENT TYPE STRING,
OIO_MATNR TYPE STRING,
OIO_MBTXT TYPE STRING,
OIO_MBMNG TYPE STRING,
OIO_MBMEI TYPE STRING,
OIO_MENGE TYPE STRING,
OIO_MEINS TYPE STRING,
OIO_RMOBSTAT TYPE STRING,
OIO_RNUMPACK TYPE STRING,
OIO_RVENDREF TYPE STRING,
OIO_RX_PRT TYPE STRING,
OIO_ACT_MBMNG TYPE STRING,
OIO_ACT_MBMEI TYPE STRING,
OIO_ACT_DMBMNG TYPE STRING,
OIO_ACT_DMBMEI TYPE STRING,
DOCNR TYPE STRING,
RECTY TYPE STRING,
DOCLN TYPE STRING,END OF T_EKKO_STR. DATA: WA_ROIO_RT_ESLL_LIST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ROIO_RT_ESLL_LIST_STR-AUFNR sy-vline
WA_ROIO_RT_ESLL_LIST_STR-AUART sy-vline
WA_ROIO_RT_ESLL_LIST_STR-AUTYP sy-vline
WA_ROIO_RT_ESLL_LIST_STR-AUFPL sy-vline
WA_ROIO_RT_ESLL_LIST_STR-APLZL sy-vline
WA_ROIO_RT_ESLL_LIST_STR-VORNR sy-vline
WA_ROIO_RT_ESLL_LIST_STR-REFNR sy-vline
WA_ROIO_RT_ESLL_LIST_STR-ERNAM sy-vline
WA_ROIO_RT_ESLL_LIST_STR-ERDAT sy-vline
WA_ROIO_RT_ESLL_LIST_STR-AENAM sy-vline
WA_ROIO_RT_ESLL_LIST_STR-AEDAT sy-vline
WA_ROIO_RT_ESLL_LIST_STR-KTEXT sy-vline
WA_ROIO_RT_ESLL_LIST_STR-BUKRS sy-vline
WA_ROIO_RT_ESLL_LIST_STR-KOKRS sy-vline
WA_ROIO_RT_ESLL_LIST_STR-CCKEY sy-vline
WA_ROIO_RT_ESLL_LIST_STR-KOSTV sy-vline
WA_ROIO_RT_ESLL_LIST_STR-PRCTR sy-vline
WA_ROIO_RT_ESLL_LIST_STR-PSPEL sy-vline
WA_ROIO_RT_ESLL_LIST_STR-WERKS sy-vline
WA_ROIO_RT_ESLL_LIST_STR-PACKNO sy-vline
WA_ROIO_RT_ESLL_LIST_STR-INTROW sy-vline
WA_ROIO_RT_ESLL_LIST_STR-EXTROW sy-vline
WA_ROIO_RT_ESLL_LIST_STR-SRVPOS sy-vline
WA_ROIO_RT_ESLL_LIST_STR-KTEXT1 sy-vline
WA_ROIO_RT_ESLL_LIST_STR-OIO_XRENT sy-vline
WA_ROIO_RT_ESLL_LIST_STR-OIO_MATNR sy-vline
WA_ROIO_RT_ESLL_LIST_STR-OIO_MBTXT sy-vline
WA_ROIO_RT_ESLL_LIST_STR-OIO_MBMNG sy-vline
WA_ROIO_RT_ESLL_LIST_STR-OIO_MBMEI sy-vline
WA_ROIO_RT_ESLL_LIST_STR-OIO_MENGE sy-vline
WA_ROIO_RT_ESLL_LIST_STR-OIO_MEINS sy-vline
WA_ROIO_RT_ESLL_LIST_STR-OIO_RMOBSTAT sy-vline
WA_ROIO_RT_ESLL_LIST_STR-OIO_RNUMPACK sy-vline
WA_ROIO_RT_ESLL_LIST_STR-OIO_RVENDREF sy-vline
WA_ROIO_RT_ESLL_LIST_STR-OIO_RX_PRT sy-vline
WA_ROIO_RT_ESLL_LIST_STR-OIO_ACT_MBMNG sy-vline
WA_ROIO_RT_ESLL_LIST_STR-OIO_ACT_MBMEI sy-vline
WA_ROIO_RT_ESLL_LIST_STR-OIO_ACT_DMBMNG sy-vline
WA_ROIO_RT_ESLL_LIST_STR-OIO_ACT_DMBMEI sy-vline
WA_ROIO_RT_ESLL_LIST_STR-DOCNR sy-vline
WA_ROIO_RT_ESLL_LIST_STR-RECTY sy-vline
WA_ROIO_RT_ESLL_LIST_STR-DOCLN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.