ABAP Select data from SAP table ROIU_PR_NTWKWC_E into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP ROIU_PR_NTWKWC_E table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ROIU_PR_NTWKWC_E. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the ROIU_PR_NTWKWC_E table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_ROIU_PR_NTWKWC_E TYPE STANDARD TABLE OF ROIU_PR_NTWKWC_E, WA_ROIU_PR_NTWKWC_E TYPE ROIU_PR_NTWKWC_E, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <ROIU_PR_NTWKWC_E> TYPE ROIU_PR_NTWKWC_E. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_ROIU_PR_NTWKWC_E. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM ROIU_PR_NTWKWC_E INTO TABLE IT_ROIU_PR_NTWKWC_E. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM ROIU_PR_NTWKWC_E * INTO TABLE @DATA(IT_ROIU_PR_NTWKWC_E2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_ROIU_PR_NTWKWC_E INDEX 1 INTO DATA(WA_ROIU_PR_NTWKWC_E2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_ROIU_PR_NTWKWC_E ASSIGNING <ROIU_PR_NTWKWC_E>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<ROIU_PR_NTWKWC_E>-WL_NO = 1.
<ROIU_PR_NTWKWC_E>-WC_NO = 1.
<ROIU_PR_NTWKWC_E>-NAME = 1.
<ROIU_PR_NTWKWC_E>-CONTN_FL = 1.
<ROIU_PR_NTWKWC_E>-PRD_MTH_CD = 1.
ENDLOOP. LOOP AT IT_ROIU_PR_NTWKWC_E INTO WA_ROIU_PR_NTWKWC_E. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_ROIU_PR_NTWKWC_E-WL_CLASS_CD, sy-vline,
WA_ROIU_PR_NTWKWC_E-CRUD_TYP_CD, sy-vline,
WA_ROIU_PR_NTWKWC_E-PRI_GEO_LOC, sy-vline,
WA_ROIU_PR_NTWKWC_E-SEC_GEO_LOC, sy-vline,
WA_ROIU_PR_NTWKWC_E-PUR_CD, sy-vline,
WA_ROIU_PR_NTWKWC_E-PF_NO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ROIU_PR_NTWKWC_E you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ROIU_PR_NTWKWC_E TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ROIU_PR_NTWKWC_E INTO WA_ROIU_PR_NTWKWC_E. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field WL_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIU_PR_NTWKWC_E-WL_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIU_PR_NTWKWC_E-WL_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field WC_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIU_PR_NTWKWC_E-WC_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIU_PR_NTWKWC_E-WC_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PF_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIU_PR_NTWKWC_E-PF_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIU_PR_NTWKWC_E-PF_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field RPRD_MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_ROIU_PR_NTWKWC_E-RPRD_MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIU_PR_NTWKWC_E-RPRD_MATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PARENT_WL_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIU_PR_NTWKWC_E-PARENT_WL_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIU_PR_NTWKWC_E-PARENT_WL_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PARENT_WC_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIU_PR_NTWKWC_E-PARENT_WC_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIU_PR_NTWKWC_E-PARENT_WC_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field VNAME CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIU_PR_NTWKWC_E-VNAME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIU_PR_NTWKWC_E-VNAME.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field LO_PRES_MP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIU_PR_NTWKWC_E-LO_PRES_MP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIU_PR_NTWKWC_E-LO_PRES_MP.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field HI_PRES_MP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIU_PR_NTWKWC_E-HI_PRES_MP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIU_PR_NTWKWC_E-HI_PRES_MP.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field STD_VOL_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROIU_PR_NTWKWC_E-STD_VOL_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIU_PR_NTWKWC_E-STD_VOL_U.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ROIU_PR_NTWKWC_E_STR,
WL_NO TYPE STRING,
WC_NO TYPE STRING,
NAME TYPE STRING,
CONTN_FL TYPE STRING,
PRD_MTH_CD TYPE STRING,
WL_CLASS_CD TYPE STRING,
CRUD_TYP_CD TYPE STRING,
PRI_GEO_LOC TYPE STRING,
SEC_GEO_LOC TYPE STRING,
PUR_CD TYPE STRING,
PF_NO TYPE STRING,
CHA_FND TYPE STRING,
OFFSH_FL TYPE STRING,
FRM_PC TYPE STRING,
RPRD_MAJPD_CD TYPE STRING,
RPRD_PD_CD TYPE STRING,
RPRD_MATNR TYPE STRING,
GAS_VALUATION_PT_FL TYPE STRING,
NGL_VALUATION_PT_FL TYPE STRING,
CONTAM_IND_FL TYPE STRING,
CT_CONTAM_MAJPD_CD TYPE STRING,
CT_CONTAM_PD_CD TYPE STRING,
CONTAM_PC TYPE STRING,
DNSTR_SPLIT_FL TYPE STRING,
DEDUCT_THEO_FL TYPE STRING,
PARENT_WL_NO TYPE STRING,
PARENT_WC_NO TYPE STRING,
EXCH_ON_LSE TYPE STRING,
EXCH_OFF_LSE TYPE STRING,
CMNGLD_PC TYPE STRING,
DAYS_PROD TYPE STRING,
MST_TYPE1 TYPE STRING,
MST_TYPE2 TYPE STRING,
MST_DFLT TYPE STRING,
FUN_FL TYPE STRING,
SUP_PCVT_FL TYPE STRING,
SUP_PDCD_FL TYPE STRING,
BUKRS TYPE STRING,
VNAME TYPE STRING,
AB_ADJ_FL TYPE STRING,
STATUS_CD TYPE STRING,
EXT_LOSS_PC TYPE STRING,
SUP_MAJPD_FL TYPE STRING,
MULT_RLF_FL TYPE STRING,
INJECT_VOL TYPE STRING,
THEO_RESIDUE TYPE STRING,
BEG_REM_INV TYPE STRING,
BEG_INV_QY TYPE STRING,
TOP_LEVEL_MTR TYPE STRING,
GP_METERED_PROD TYPE STRING,
METERED_PROD TYPE STRING,
CALCD_PROD TYPE STRING,
TOTAL_EXTR_LOSS TYPE STRING,
TOTAL_SALES_QY TYPE STRING,
TOTAL_OFFLSE_QY TYPE STRING,
TOTAL_ONLSE_QY TYPE STRING,
LOAD_OIL_EFF_DT TYPE STRING,
LOAD_OIL_FL TYPE STRING,
ADJ_LO_PRES_QY TYPE STRING,
ADJ_HI_PRES_QY TYPE STRING,
LO_PRES_QY TYPE STRING,
HI_PRES_QY TYPE STRING,
LO_PRES_MP TYPE STRING,
HI_PRES_MP TYPE STRING,
WC_HAS_HILO_PRES TYPE STRING,
SUP_PCVT_SPL_FL TYPE STRING,
SUP_CONTAM_PD_FL TYPE STRING,
WC_IS_MTRD TYPE STRING,
PRD_HRS TYPE STRING,
ALLOC_VOL TYPE STRING,
STD_VOL_U TYPE STRING,
THEO_RAT_FAC TYPE STRING,
THEO_QY TYPE STRING,
ORIG_THEO_QY TYPE STRING,
ADJ_THEO_QY TYPE STRING,
THEO_QY_SPLIT TYPE STRING,
UP_SPLIT_QY TYPE STRING,
UP_SPLIT_QY_CALC TYPE STRING,
UP_SPLIT_QY_HOLD TYPE STRING,
GL_REC_QY TYPE STRING,
BTU_FAC_VOL TYPE STRING,
VRU_THEO_QY TYPE STRING,
NGL_C1C2TRA_QY TYPE STRING,
SUM_NGL_QY TYPE STRING,
SUM_NGL_MOL_QY TYPE STRING,
TABIX_COTB TYPE STRING,END OF T_EKKO_STR. DATA: WA_ROIU_PR_NTWKWC_E_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ROIU_PR_NTWKWC_E_STR-WL_NO sy-vline
WA_ROIU_PR_NTWKWC_E_STR-WC_NO sy-vline
WA_ROIU_PR_NTWKWC_E_STR-NAME sy-vline
WA_ROIU_PR_NTWKWC_E_STR-CONTN_FL sy-vline
WA_ROIU_PR_NTWKWC_E_STR-PRD_MTH_CD sy-vline
WA_ROIU_PR_NTWKWC_E_STR-WL_CLASS_CD sy-vline
WA_ROIU_PR_NTWKWC_E_STR-CRUD_TYP_CD sy-vline
WA_ROIU_PR_NTWKWC_E_STR-PRI_GEO_LOC sy-vline
WA_ROIU_PR_NTWKWC_E_STR-SEC_GEO_LOC sy-vline
WA_ROIU_PR_NTWKWC_E_STR-PUR_CD sy-vline
WA_ROIU_PR_NTWKWC_E_STR-PF_NO sy-vline
WA_ROIU_PR_NTWKWC_E_STR-CHA_FND sy-vline
WA_ROIU_PR_NTWKWC_E_STR-OFFSH_FL sy-vline
WA_ROIU_PR_NTWKWC_E_STR-FRM_PC sy-vline
WA_ROIU_PR_NTWKWC_E_STR-RPRD_MAJPD_CD sy-vline
WA_ROIU_PR_NTWKWC_E_STR-RPRD_PD_CD sy-vline
WA_ROIU_PR_NTWKWC_E_STR-RPRD_MATNR sy-vline
WA_ROIU_PR_NTWKWC_E_STR-GAS_VALUATION_PT_FL sy-vline
WA_ROIU_PR_NTWKWC_E_STR-NGL_VALUATION_PT_FL sy-vline
WA_ROIU_PR_NTWKWC_E_STR-CONTAM_IND_FL sy-vline
WA_ROIU_PR_NTWKWC_E_STR-CT_CONTAM_MAJPD_CD sy-vline
WA_ROIU_PR_NTWKWC_E_STR-CT_CONTAM_PD_CD sy-vline
WA_ROIU_PR_NTWKWC_E_STR-CONTAM_PC sy-vline
WA_ROIU_PR_NTWKWC_E_STR-DNSTR_SPLIT_FL sy-vline
WA_ROIU_PR_NTWKWC_E_STR-DEDUCT_THEO_FL sy-vline
WA_ROIU_PR_NTWKWC_E_STR-PARENT_WL_NO sy-vline
WA_ROIU_PR_NTWKWC_E_STR-PARENT_WC_NO sy-vline
WA_ROIU_PR_NTWKWC_E_STR-EXCH_ON_LSE sy-vline
WA_ROIU_PR_NTWKWC_E_STR-EXCH_OFF_LSE sy-vline
WA_ROIU_PR_NTWKWC_E_STR-CMNGLD_PC sy-vline
WA_ROIU_PR_NTWKWC_E_STR-DAYS_PROD sy-vline
WA_ROIU_PR_NTWKWC_E_STR-MST_TYPE1 sy-vline
WA_ROIU_PR_NTWKWC_E_STR-MST_TYPE2 sy-vline
WA_ROIU_PR_NTWKWC_E_STR-MST_DFLT sy-vline
WA_ROIU_PR_NTWKWC_E_STR-FUN_FL sy-vline
WA_ROIU_PR_NTWKWC_E_STR-SUP_PCVT_FL sy-vline
WA_ROIU_PR_NTWKWC_E_STR-SUP_PDCD_FL sy-vline
WA_ROIU_PR_NTWKWC_E_STR-BUKRS sy-vline
WA_ROIU_PR_NTWKWC_E_STR-VNAME sy-vline
WA_ROIU_PR_NTWKWC_E_STR-AB_ADJ_FL sy-vline
WA_ROIU_PR_NTWKWC_E_STR-STATUS_CD sy-vline
WA_ROIU_PR_NTWKWC_E_STR-EXT_LOSS_PC sy-vline
WA_ROIU_PR_NTWKWC_E_STR-SUP_MAJPD_FL sy-vline
WA_ROIU_PR_NTWKWC_E_STR-MULT_RLF_FL sy-vline
WA_ROIU_PR_NTWKWC_E_STR-INJECT_VOL sy-vline
WA_ROIU_PR_NTWKWC_E_STR-THEO_RESIDUE sy-vline
WA_ROIU_PR_NTWKWC_E_STR-BEG_REM_INV sy-vline
WA_ROIU_PR_NTWKWC_E_STR-BEG_INV_QY sy-vline
WA_ROIU_PR_NTWKWC_E_STR-TOP_LEVEL_MTR sy-vline
WA_ROIU_PR_NTWKWC_E_STR-GP_METERED_PROD sy-vline
WA_ROIU_PR_NTWKWC_E_STR-METERED_PROD sy-vline
WA_ROIU_PR_NTWKWC_E_STR-CALCD_PROD sy-vline
WA_ROIU_PR_NTWKWC_E_STR-TOTAL_EXTR_LOSS sy-vline
WA_ROIU_PR_NTWKWC_E_STR-TOTAL_SALES_QY sy-vline
WA_ROIU_PR_NTWKWC_E_STR-TOTAL_OFFLSE_QY sy-vline
WA_ROIU_PR_NTWKWC_E_STR-TOTAL_ONLSE_QY sy-vline
WA_ROIU_PR_NTWKWC_E_STR-LOAD_OIL_EFF_DT sy-vline
WA_ROIU_PR_NTWKWC_E_STR-LOAD_OIL_FL sy-vline
WA_ROIU_PR_NTWKWC_E_STR-ADJ_LO_PRES_QY sy-vline
WA_ROIU_PR_NTWKWC_E_STR-ADJ_HI_PRES_QY sy-vline
WA_ROIU_PR_NTWKWC_E_STR-LO_PRES_QY sy-vline
WA_ROIU_PR_NTWKWC_E_STR-HI_PRES_QY sy-vline
WA_ROIU_PR_NTWKWC_E_STR-LO_PRES_MP sy-vline
WA_ROIU_PR_NTWKWC_E_STR-HI_PRES_MP sy-vline
WA_ROIU_PR_NTWKWC_E_STR-WC_HAS_HILO_PRES sy-vline
WA_ROIU_PR_NTWKWC_E_STR-SUP_PCVT_SPL_FL sy-vline
WA_ROIU_PR_NTWKWC_E_STR-SUP_CONTAM_PD_FL sy-vline
WA_ROIU_PR_NTWKWC_E_STR-WC_IS_MTRD sy-vline
WA_ROIU_PR_NTWKWC_E_STR-PRD_HRS sy-vline
WA_ROIU_PR_NTWKWC_E_STR-ALLOC_VOL sy-vline
WA_ROIU_PR_NTWKWC_E_STR-STD_VOL_U sy-vline
WA_ROIU_PR_NTWKWC_E_STR-THEO_RAT_FAC sy-vline
WA_ROIU_PR_NTWKWC_E_STR-THEO_QY sy-vline
WA_ROIU_PR_NTWKWC_E_STR-ORIG_THEO_QY sy-vline
WA_ROIU_PR_NTWKWC_E_STR-ADJ_THEO_QY sy-vline
WA_ROIU_PR_NTWKWC_E_STR-THEO_QY_SPLIT sy-vline
WA_ROIU_PR_NTWKWC_E_STR-UP_SPLIT_QY sy-vline
WA_ROIU_PR_NTWKWC_E_STR-UP_SPLIT_QY_CALC sy-vline
WA_ROIU_PR_NTWKWC_E_STR-UP_SPLIT_QY_HOLD sy-vline
WA_ROIU_PR_NTWKWC_E_STR-GL_REC_QY sy-vline
WA_ROIU_PR_NTWKWC_E_STR-BTU_FAC_VOL sy-vline
WA_ROIU_PR_NTWKWC_E_STR-VRU_THEO_QY sy-vline
WA_ROIU_PR_NTWKWC_E_STR-NGL_C1C2TRA_QY sy-vline
WA_ROIU_PR_NTWKWC_E_STR-SUM_NGL_QY sy-vline
WA_ROIU_PR_NTWKWC_E_STR-SUM_NGL_MOL_QY sy-vline
WA_ROIU_PR_NTWKWC_E_STR-TABIX_COTB sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.