ABAP Select data from SAP table ROIU_SB_RES_RPT1_ALV1 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP ROIU_SB_RES_RPT1_ALV1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ROIU_SB_RES_RPT1_ALV1. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the ROIU_SB_RES_RPT1_ALV1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_ROIU_SB_RES_RPT1_ALV1 TYPE STANDARD TABLE OF ROIU_SB_RES_RPT1_ALV1, WA_ROIU_SB_RES_RPT1_ALV1 TYPE ROIU_SB_RES_RPT1_ALV1, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <ROIU_SB_RES_RPT1_ALV1> TYPE ROIU_SB_RES_RPT1_ALV1. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_ROIU_SB_RES_RPT1_ALV1. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM ROIU_SB_RES_RPT1_ALV1 INTO TABLE IT_ROIU_SB_RES_RPT1_ALV1. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM ROIU_SB_RES_RPT1_ALV1 * INTO TABLE @DATA(IT_ROIU_SB_RES_RPT1_ALV12). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_ROIU_SB_RES_RPT1_ALV1 INDEX 1 INTO DATA(WA_ROIU_SB_RES_RPT1_ALV12). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_ROIU_SB_RES_RPT1_ALV1 ASSIGNING <ROIU_SB_RES_RPT1_ALV1>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<ROIU_SB_RES_RPT1_ALV1>-WELL_NO = 1.
<ROIU_SB_RES_RPT1_ALV1>-WC_NO = 1.
<ROIU_SB_RES_RPT1_ALV1>-WELL_DES = 1.
<ROIU_SB_RES_RPT1_ALV1>-MP_NO = 1.
<ROIU_SB_RES_RPT1_ALV1>-MP_DES = 1.
ENDLOOP. LOOP AT IT_ROIU_SB_RES_RPT1_ALV1 INTO WA_ROIU_SB_RES_RPT1_ALV1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_ROIU_SB_RES_RPT1_ALV1-MK_REP_NO, sy-vline,
WA_ROIU_SB_RES_RPT1_ALV1-MK_ISQ_NO, sy-vline,
WA_ROIU_SB_RES_RPT1_ALV1-MK_REP_NAME, sy-vline,
WA_ROIU_SB_RES_RPT1_ALV1-BASIS_QTY, sy-vline,
WA_ROIU_SB_RES_RPT1_ALV1-OWN_NO, sy-vline,
WA_ROIU_SB_RES_RPT1_ALV1-OWN_INT_TYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ROIU_SB_RES_RPT1_ALV1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ROIU_SB_RES_RPT1_ALV1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ROIU_SB_RES_RPT1_ALV1 INTO WA_ROIU_SB_RES_RPT1_ALV1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field WELL_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIU_SB_RES_RPT1_ALV1-WELL_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIU_SB_RES_RPT1_ALV1-WELL_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field WC_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIU_SB_RES_RPT1_ALV1-WC_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIU_SB_RES_RPT1_ALV1-WC_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field OWN_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIU_SB_RES_RPT1_ALV1-OWN_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIU_SB_RES_RPT1_ALV1-OWN_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field OWN_ISQ CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIU_SB_RES_RPT1_ALV1-OWN_ISQ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIU_SB_RES_RPT1_ALV1-OWN_ISQ.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ROIU_SB_RES_RPT1_ALV1_STR,
WELL_NO TYPE STRING,
WC_NO TYPE STRING,
WELL_DES TYPE STRING,
MP_NO TYPE STRING,
MP_DES TYPE STRING,
MK_REP_NO TYPE STRING,
MK_ISQ_NO TYPE STRING,
MK_REP_NAME TYPE STRING,
BASIS_QTY TYPE STRING,
OWN_NO TYPE STRING,
OWN_INT_TYPE TYPE STRING,
OWN_ISQ TYPE STRING,
OWN_FLAG_KW TYPE STRING,
CT_NO TYPE STRING,
CT_TYPE_CD TYPE STRING,
VOL_BASIS TYPE STRING,
ACTL_VOL TYPE STRING,
ACTL_ENERGY TYPE STRING,
LIST_COUNT TYPE STRING,END OF T_EKKO_STR. DATA: WA_ROIU_SB_RES_RPT1_ALV1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ROIU_SB_RES_RPT1_ALV1_STR-WELL_NO sy-vline
WA_ROIU_SB_RES_RPT1_ALV1_STR-WC_NO sy-vline
WA_ROIU_SB_RES_RPT1_ALV1_STR-WELL_DES sy-vline
WA_ROIU_SB_RES_RPT1_ALV1_STR-MP_NO sy-vline
WA_ROIU_SB_RES_RPT1_ALV1_STR-MP_DES sy-vline
WA_ROIU_SB_RES_RPT1_ALV1_STR-MK_REP_NO sy-vline
WA_ROIU_SB_RES_RPT1_ALV1_STR-MK_ISQ_NO sy-vline
WA_ROIU_SB_RES_RPT1_ALV1_STR-MK_REP_NAME sy-vline
WA_ROIU_SB_RES_RPT1_ALV1_STR-BASIS_QTY sy-vline
WA_ROIU_SB_RES_RPT1_ALV1_STR-OWN_NO sy-vline
WA_ROIU_SB_RES_RPT1_ALV1_STR-OWN_INT_TYPE sy-vline
WA_ROIU_SB_RES_RPT1_ALV1_STR-OWN_ISQ sy-vline
WA_ROIU_SB_RES_RPT1_ALV1_STR-OWN_FLAG_KW sy-vline
WA_ROIU_SB_RES_RPT1_ALV1_STR-CT_NO sy-vline
WA_ROIU_SB_RES_RPT1_ALV1_STR-CT_TYPE_CD sy-vline
WA_ROIU_SB_RES_RPT1_ALV1_STR-VOL_BASIS sy-vline
WA_ROIU_SB_RES_RPT1_ALV1_STR-ACTL_VOL sy-vline
WA_ROIU_SB_RES_RPT1_ALV1_STR-ACTL_ENERGY sy-vline
WA_ROIU_SB_RES_RPT1_ALV1_STR-LIST_COUNT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.