ABAP Select data from SAP table ROIUPR_WCCO into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP ROIUPR_WCCO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ROIUPR_WCCO. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the ROIUPR_WCCO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_ROIUPR_WCCO TYPE STANDARD TABLE OF ROIUPR_WCCO, WA_ROIUPR_WCCO TYPE ROIUPR_WCCO, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <ROIUPR_WCCO> TYPE ROIUPR_WCCO. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_ROIUPR_WCCO. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM ROIUPR_WCCO INTO TABLE IT_ROIUPR_WCCO. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM ROIUPR_WCCO * INTO TABLE @DATA(IT_ROIUPR_WCCO2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_ROIUPR_WCCO INDEX 1 INTO DATA(WA_ROIUPR_WCCO2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_ROIUPR_WCCO ASSIGNING <ROIUPR_WCCO>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<ROIUPR_WCCO>-WL_NO = 1.
<ROIUPR_WCCO>-WC_NO = 1.
<ROIUPR_WCCO>-GPLT_CMPNT_CD = 1.
<ROIUPR_WCCO>-HLD_ADJ_THEO_QY = 1.
<ROIUPR_WCCO>-INJECT_VOL = 1.
ENDLOOP. LOOP AT IT_ROIUPR_WCCO INTO WA_ROIUPR_WCCO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_ROIUPR_WCCO-THEO_RESIDUE, sy-vline,
WA_ROIUPR_WCCO-BEG_REM_INV, sy-vline,
WA_ROIUPR_WCCO-BEG_INV_QY, sy-vline,
WA_ROIUPR_WCCO-TOP_LEVEL_MTR, sy-vline,
WA_ROIUPR_WCCO-GP_METERED_PROD, sy-vline,
WA_ROIUPR_WCCO-METERED_PROD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ROIUPR_WCCO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ROIUPR_WCCO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ROIUPR_WCCO INTO WA_ROIUPR_WCCO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field WL_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIUPR_WCCO-WL_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUPR_WCCO-WL_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field WC_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIUPR_WCCO-WC_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUPR_WCCO-WC_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field LO_PRES_MP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIUPR_WCCO-LO_PRES_MP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUPR_WCCO-LO_PRES_MP.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field HI_PRES_MP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIUPR_WCCO-HI_PRES_MP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUPR_WCCO-HI_PRES_MP.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field STD_VOL_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROIUPR_WCCO-STD_VOL_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUPR_WCCO-STD_VOL_U.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ROIUPR_WCCO_STR,
WL_NO TYPE STRING,
WC_NO TYPE STRING,
GPLT_CMPNT_CD TYPE STRING,
HLD_ADJ_THEO_QY TYPE STRING,
INJECT_VOL TYPE STRING,
THEO_RESIDUE TYPE STRING,
BEG_REM_INV TYPE STRING,
BEG_INV_QY TYPE STRING,
TOP_LEVEL_MTR TYPE STRING,
GP_METERED_PROD TYPE STRING,
METERED_PROD TYPE STRING,
CALCD_PROD TYPE STRING,
TOTAL_EXTR_LOSS TYPE STRING,
TOTAL_SALES_QY TYPE STRING,
TOTAL_OFFLSE_QY TYPE STRING,
TOTAL_ONLSE_QY TYPE STRING,
LOAD_OIL_EFF_DT TYPE STRING,
LOAD_OIL_FL TYPE STRING,
ADJ_LO_PRES_QY TYPE STRING,
ADJ_HI_PRES_QY TYPE STRING,
LO_PRES_QY TYPE STRING,
HI_PRES_QY TYPE STRING,
LO_PRES_MP TYPE STRING,
HI_PRES_MP TYPE STRING,
WC_HAS_HILO_PRES TYPE STRING,
SUP_PCVT_SPL_FL TYPE STRING,
SUP_CONTAM_PD_FL TYPE STRING,
WC_IS_MTRD TYPE STRING,
PRD_HRS TYPE STRING,
ALLOC_VOL TYPE STRING,
STD_VOL_U TYPE STRING,
THEO_RAT_FAC TYPE STRING,
THEO_QY TYPE STRING,
ORIG_THEO_QY TYPE STRING,
ADJ_THEO_QY TYPE STRING,
THEO_QY_SPLIT TYPE STRING,
UP_SPLIT_QY TYPE STRING,
UP_SPLIT_QY_CALC TYPE STRING,
UP_SPLIT_QY_HOLD TYPE STRING,
GL_REC_QY TYPE STRING,
BTU_FAC_VOL TYPE STRING,
VRU_THEO_QY TYPE STRING,
NGL_C1C2TRA_QY TYPE STRING,
SUM_NGL_QY TYPE STRING,
SUM_NGL_MOL_QY TYPE STRING,
TABIX_COTB TYPE STRING,END OF T_EKKO_STR. DATA: WA_ROIUPR_WCCO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ROIUPR_WCCO_STR-WL_NO sy-vline
WA_ROIUPR_WCCO_STR-WC_NO sy-vline
WA_ROIUPR_WCCO_STR-GPLT_CMPNT_CD sy-vline
WA_ROIUPR_WCCO_STR-HLD_ADJ_THEO_QY sy-vline
WA_ROIUPR_WCCO_STR-INJECT_VOL sy-vline
WA_ROIUPR_WCCO_STR-THEO_RESIDUE sy-vline
WA_ROIUPR_WCCO_STR-BEG_REM_INV sy-vline
WA_ROIUPR_WCCO_STR-BEG_INV_QY sy-vline
WA_ROIUPR_WCCO_STR-TOP_LEVEL_MTR sy-vline
WA_ROIUPR_WCCO_STR-GP_METERED_PROD sy-vline
WA_ROIUPR_WCCO_STR-METERED_PROD sy-vline
WA_ROIUPR_WCCO_STR-CALCD_PROD sy-vline
WA_ROIUPR_WCCO_STR-TOTAL_EXTR_LOSS sy-vline
WA_ROIUPR_WCCO_STR-TOTAL_SALES_QY sy-vline
WA_ROIUPR_WCCO_STR-TOTAL_OFFLSE_QY sy-vline
WA_ROIUPR_WCCO_STR-TOTAL_ONLSE_QY sy-vline
WA_ROIUPR_WCCO_STR-LOAD_OIL_EFF_DT sy-vline
WA_ROIUPR_WCCO_STR-LOAD_OIL_FL sy-vline
WA_ROIUPR_WCCO_STR-ADJ_LO_PRES_QY sy-vline
WA_ROIUPR_WCCO_STR-ADJ_HI_PRES_QY sy-vline
WA_ROIUPR_WCCO_STR-LO_PRES_QY sy-vline
WA_ROIUPR_WCCO_STR-HI_PRES_QY sy-vline
WA_ROIUPR_WCCO_STR-LO_PRES_MP sy-vline
WA_ROIUPR_WCCO_STR-HI_PRES_MP sy-vline
WA_ROIUPR_WCCO_STR-WC_HAS_HILO_PRES sy-vline
WA_ROIUPR_WCCO_STR-SUP_PCVT_SPL_FL sy-vline
WA_ROIUPR_WCCO_STR-SUP_CONTAM_PD_FL sy-vline
WA_ROIUPR_WCCO_STR-WC_IS_MTRD sy-vline
WA_ROIUPR_WCCO_STR-PRD_HRS sy-vline
WA_ROIUPR_WCCO_STR-ALLOC_VOL sy-vline
WA_ROIUPR_WCCO_STR-STD_VOL_U sy-vline
WA_ROIUPR_WCCO_STR-THEO_RAT_FAC sy-vline
WA_ROIUPR_WCCO_STR-THEO_QY sy-vline
WA_ROIUPR_WCCO_STR-ORIG_THEO_QY sy-vline
WA_ROIUPR_WCCO_STR-ADJ_THEO_QY sy-vline
WA_ROIUPR_WCCO_STR-THEO_QY_SPLIT sy-vline
WA_ROIUPR_WCCO_STR-UP_SPLIT_QY sy-vline
WA_ROIUPR_WCCO_STR-UP_SPLIT_QY_CALC sy-vline
WA_ROIUPR_WCCO_STR-UP_SPLIT_QY_HOLD sy-vline
WA_ROIUPR_WCCO_STR-GL_REC_QY sy-vline
WA_ROIUPR_WCCO_STR-BTU_FAC_VOL sy-vline
WA_ROIUPR_WCCO_STR-VRU_THEO_QY sy-vline
WA_ROIUPR_WCCO_STR-NGL_C1C2TRA_QY sy-vline
WA_ROIUPR_WCCO_STR-SUM_NGL_QY sy-vline
WA_ROIUPR_WCCO_STR-SUM_NGL_MOL_QY sy-vline
WA_ROIUPR_WCCO_STR-TABIX_COTB sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.