ABAP Select data from SAP table ROIUREP_WY_M1_D into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP ROIUREP_WY_M1_D table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ROIUREP_WY_M1_D. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the ROIUREP_WY_M1_D table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_ROIUREP_WY_M1_D TYPE STANDARD TABLE OF ROIUREP_WY_M1_D, WA_ROIUREP_WY_M1_D TYPE ROIUREP_WY_M1_D, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <ROIUREP_WY_M1_D> TYPE ROIUREP_WY_M1_D. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_ROIUREP_WY_M1_D. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM ROIUREP_WY_M1_D INTO TABLE IT_ROIUREP_WY_M1_D. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM ROIUREP_WY_M1_D * INTO TABLE @DATA(IT_ROIUREP_WY_M1_D2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_ROIUREP_WY_M1_D INDEX 1 INTO DATA(WA_ROIUREP_WY_M1_D2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_ROIUREP_WY_M1_D ASSIGNING <ROIUREP_WY_M1_D>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<ROIUREP_WY_M1_D>-FIELD = 1.
<ROIUREP_WY_M1_D>-AGENCY = 1.
<ROIUREP_WY_M1_D>-AGENCY_PD_CD = 1.
<ROIUREP_WY_M1_D>-YEAR_MONTH = 1.
<ROIUREP_WY_M1_D>-YEAR_MONTH_AMND = 1.
ENDLOOP. LOOP AT IT_ROIUREP_WY_M1_D INTO WA_ROIUREP_WY_M1_D. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_ROIUREP_WY_M1_D-AGENCY_LEASE, sy-vline,
WA_ROIUREP_WY_M1_D-OIL_GAS_IND, sy-vline,
WA_ROIUREP_WY_M1_D-OPR_VOL_W1, sy-vline,
WA_ROIUREP_WY_M1_D-OPR_PPU_W1, sy-vline,
WA_ROIUREP_WY_M1_D-OPR_VAL_W1, sy-vline,
WA_ROIUREP_WY_M1_D-OPR_ROY_PER_W1, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ROIUREP_WY_M1_D you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ROIUREP_WY_M1_D TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ROIUREP_WY_M1_D INTO WA_ROIUREP_WY_M1_D. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field FIELD CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIUREP_WY_M1_D-FIELD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUREP_WY_M1_D-FIELD.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ROIUREP_WY_M1_D_STR,
FIELD TYPE STRING,
AGENCY TYPE STRING,
AGENCY_PD_CD TYPE STRING,
YEAR_MONTH TYPE STRING,
YEAR_MONTH_AMND TYPE STRING,
AGENCY_LEASE TYPE STRING,
OIL_GAS_IND TYPE STRING,
OPR_VOL_W1 TYPE STRING,
OPR_PPU_W1 TYPE STRING,
OPR_VAL_W1 TYPE STRING,
OPR_ROY_PER_W1 TYPE STRING,
OPR_VOL_S1 TYPE STRING,
OPR_PPU_S1 TYPE STRING,
OPR_VAL_S1 TYPE STRING,
OPR_ROY_PER_S1 TYPE STRING,
OSLD_VOL_W1 TYPE STRING,
OSLD_PPU_W1 TYPE STRING,
OSLD_VAL_W1 TYPE STRING,
OSLD_ROY_PER_W1 TYPE STRING,
OSLD_VOL_S1 TYPE STRING,
OSLD_PPU_S1 TYPE STRING,
OSLD_VAL_S1 TYPE STRING,
OSLD_ROY_PER_S1 TYPE STRING,
CON_PRD_VOL_W2 TYPE STRING,
CON_PRD_PPU_W2 TYPE STRING,
CON_PRD_VAL_W2 TYPE STRING,
CON_PRD_ROY_PER_W2 TYPE STRING,
CON_PRD_VOL_S2 TYPE STRING,
CON_PRD_PPU_S2 TYPE STRING,
CON_PRD_VAL_S2 TYPE STRING,
CON_PRD_ROY_PER_S2 TYPE STRING,
CON_SLD_VOL_W2 TYPE STRING,
CON_SLD_PPU_W2 TYPE STRING,
CON_SLD_VAL_W2 TYPE STRING,
CON_SLD_ROY_PER_W2 TYPE STRING,
CON_SLD_VOL_S2 TYPE STRING,
CON_SLD_PPU_S2 TYPE STRING,
CON_SLD_VAL_S2 TYPE STRING,
CON_SLD_ROY_PER_S2 TYPE STRING,
GAS_PRD_VOL_W3 TYPE STRING,
GAS_PRD_PPU_W3 TYPE STRING,
GAS_PRD_VAL_W3 TYPE STRING,
GAS_PRD_ROY_PER_W3 TYPE STRING,
GAS_PRD_VOL_S3 TYPE STRING,
GAS_PRD_PPU_S3 TYPE STRING,
GAS_PRD_VAL_S3 TYPE STRING,
GAS_PRD_ROY_PER_S3 TYPE STRING,
GAS_SLD_VOL_W3 TYPE STRING,
GAS_SLD_PPU_W3 TYPE STRING,
GAS_SLD_VAL_W3 TYPE STRING,
GAS_SLD_ROY_PER_W3 TYPE STRING,
GAS_SLD_VOL_S3 TYPE STRING,
GAS_SLD_PPU_S3 TYPE STRING,
GAS_SLD_VAL_S3 TYPE STRING,
GAS_SLD_ROY_PER_S3 TYPE STRING,
PEN_SLD_VOL_W4 TYPE STRING,
PEN_SLD_PPU_W4 TYPE STRING,
PEN_SLD_VAL_W4 TYPE STRING,
PEN_SLD_ROY_PER_W4 TYPE STRING,
PEN_SLD_VOL_S4 TYPE STRING,
PEN_SLD_PPU_S4 TYPE STRING,
PEN_SLD_VAL_S4 TYPE STRING,
PEN_SLD_ROY_PER_S4 TYPE STRING,
BUT_SLD_VOL_W5 TYPE STRING,
BUT_SLD_PPU_W5 TYPE STRING,
BUT_SLD_VAL_W5 TYPE STRING,
BUT_SLD_ROY_PER_W5 TYPE STRING,
BUT_SLD_VOL_S5 TYPE STRING,
BUT_SLD_PPU_S5 TYPE STRING,
BUT_SLD_VAL_S5 TYPE STRING,
BUT_SLD_ROY_PER_S5 TYPE STRING,
SUL_SLD_VOL_W6 TYPE STRING,
SUL_SLD_PPU_W6 TYPE STRING,
SUL_SLD_VAL_W6 TYPE STRING,
SUL_SLD_ROY_PER_W6 TYPE STRING,
SUL_SLD_VOL_S6 TYPE STRING,
SUL_SLD_PPU_S6 TYPE STRING,
SUL_SLD_VAL_S6 TYPE STRING,
SUL_SLD_ROY_PER_S6 TYPE STRING,
REP_IND TYPE STRING,
ST_ROY_PER TYPE STRING,
COUNTY_NM TYPE STRING,END OF T_EKKO_STR. DATA: WA_ROIUREP_WY_M1_D_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ROIUREP_WY_M1_D_STR-FIELD sy-vline
WA_ROIUREP_WY_M1_D_STR-AGENCY sy-vline
WA_ROIUREP_WY_M1_D_STR-AGENCY_PD_CD sy-vline
WA_ROIUREP_WY_M1_D_STR-YEAR_MONTH sy-vline
WA_ROIUREP_WY_M1_D_STR-YEAR_MONTH_AMND sy-vline
WA_ROIUREP_WY_M1_D_STR-AGENCY_LEASE sy-vline
WA_ROIUREP_WY_M1_D_STR-OIL_GAS_IND sy-vline
WA_ROIUREP_WY_M1_D_STR-OPR_VOL_W1 sy-vline
WA_ROIUREP_WY_M1_D_STR-OPR_PPU_W1 sy-vline
WA_ROIUREP_WY_M1_D_STR-OPR_VAL_W1 sy-vline
WA_ROIUREP_WY_M1_D_STR-OPR_ROY_PER_W1 sy-vline
WA_ROIUREP_WY_M1_D_STR-OPR_VOL_S1 sy-vline
WA_ROIUREP_WY_M1_D_STR-OPR_PPU_S1 sy-vline
WA_ROIUREP_WY_M1_D_STR-OPR_VAL_S1 sy-vline
WA_ROIUREP_WY_M1_D_STR-OPR_ROY_PER_S1 sy-vline
WA_ROIUREP_WY_M1_D_STR-OSLD_VOL_W1 sy-vline
WA_ROIUREP_WY_M1_D_STR-OSLD_PPU_W1 sy-vline
WA_ROIUREP_WY_M1_D_STR-OSLD_VAL_W1 sy-vline
WA_ROIUREP_WY_M1_D_STR-OSLD_ROY_PER_W1 sy-vline
WA_ROIUREP_WY_M1_D_STR-OSLD_VOL_S1 sy-vline
WA_ROIUREP_WY_M1_D_STR-OSLD_PPU_S1 sy-vline
WA_ROIUREP_WY_M1_D_STR-OSLD_VAL_S1 sy-vline
WA_ROIUREP_WY_M1_D_STR-OSLD_ROY_PER_S1 sy-vline
WA_ROIUREP_WY_M1_D_STR-CON_PRD_VOL_W2 sy-vline
WA_ROIUREP_WY_M1_D_STR-CON_PRD_PPU_W2 sy-vline
WA_ROIUREP_WY_M1_D_STR-CON_PRD_VAL_W2 sy-vline
WA_ROIUREP_WY_M1_D_STR-CON_PRD_ROY_PER_W2 sy-vline
WA_ROIUREP_WY_M1_D_STR-CON_PRD_VOL_S2 sy-vline
WA_ROIUREP_WY_M1_D_STR-CON_PRD_PPU_S2 sy-vline
WA_ROIUREP_WY_M1_D_STR-CON_PRD_VAL_S2 sy-vline
WA_ROIUREP_WY_M1_D_STR-CON_PRD_ROY_PER_S2 sy-vline
WA_ROIUREP_WY_M1_D_STR-CON_SLD_VOL_W2 sy-vline
WA_ROIUREP_WY_M1_D_STR-CON_SLD_PPU_W2 sy-vline
WA_ROIUREP_WY_M1_D_STR-CON_SLD_VAL_W2 sy-vline
WA_ROIUREP_WY_M1_D_STR-CON_SLD_ROY_PER_W2 sy-vline
WA_ROIUREP_WY_M1_D_STR-CON_SLD_VOL_S2 sy-vline
WA_ROIUREP_WY_M1_D_STR-CON_SLD_PPU_S2 sy-vline
WA_ROIUREP_WY_M1_D_STR-CON_SLD_VAL_S2 sy-vline
WA_ROIUREP_WY_M1_D_STR-CON_SLD_ROY_PER_S2 sy-vline
WA_ROIUREP_WY_M1_D_STR-GAS_PRD_VOL_W3 sy-vline
WA_ROIUREP_WY_M1_D_STR-GAS_PRD_PPU_W3 sy-vline
WA_ROIUREP_WY_M1_D_STR-GAS_PRD_VAL_W3 sy-vline
WA_ROIUREP_WY_M1_D_STR-GAS_PRD_ROY_PER_W3 sy-vline
WA_ROIUREP_WY_M1_D_STR-GAS_PRD_VOL_S3 sy-vline
WA_ROIUREP_WY_M1_D_STR-GAS_PRD_PPU_S3 sy-vline
WA_ROIUREP_WY_M1_D_STR-GAS_PRD_VAL_S3 sy-vline
WA_ROIUREP_WY_M1_D_STR-GAS_PRD_ROY_PER_S3 sy-vline
WA_ROIUREP_WY_M1_D_STR-GAS_SLD_VOL_W3 sy-vline
WA_ROIUREP_WY_M1_D_STR-GAS_SLD_PPU_W3 sy-vline
WA_ROIUREP_WY_M1_D_STR-GAS_SLD_VAL_W3 sy-vline
WA_ROIUREP_WY_M1_D_STR-GAS_SLD_ROY_PER_W3 sy-vline
WA_ROIUREP_WY_M1_D_STR-GAS_SLD_VOL_S3 sy-vline
WA_ROIUREP_WY_M1_D_STR-GAS_SLD_PPU_S3 sy-vline
WA_ROIUREP_WY_M1_D_STR-GAS_SLD_VAL_S3 sy-vline
WA_ROIUREP_WY_M1_D_STR-GAS_SLD_ROY_PER_S3 sy-vline
WA_ROIUREP_WY_M1_D_STR-PEN_SLD_VOL_W4 sy-vline
WA_ROIUREP_WY_M1_D_STR-PEN_SLD_PPU_W4 sy-vline
WA_ROIUREP_WY_M1_D_STR-PEN_SLD_VAL_W4 sy-vline
WA_ROIUREP_WY_M1_D_STR-PEN_SLD_ROY_PER_W4 sy-vline
WA_ROIUREP_WY_M1_D_STR-PEN_SLD_VOL_S4 sy-vline
WA_ROIUREP_WY_M1_D_STR-PEN_SLD_PPU_S4 sy-vline
WA_ROIUREP_WY_M1_D_STR-PEN_SLD_VAL_S4 sy-vline
WA_ROIUREP_WY_M1_D_STR-PEN_SLD_ROY_PER_S4 sy-vline
WA_ROIUREP_WY_M1_D_STR-BUT_SLD_VOL_W5 sy-vline
WA_ROIUREP_WY_M1_D_STR-BUT_SLD_PPU_W5 sy-vline
WA_ROIUREP_WY_M1_D_STR-BUT_SLD_VAL_W5 sy-vline
WA_ROIUREP_WY_M1_D_STR-BUT_SLD_ROY_PER_W5 sy-vline
WA_ROIUREP_WY_M1_D_STR-BUT_SLD_VOL_S5 sy-vline
WA_ROIUREP_WY_M1_D_STR-BUT_SLD_PPU_S5 sy-vline
WA_ROIUREP_WY_M1_D_STR-BUT_SLD_VAL_S5 sy-vline
WA_ROIUREP_WY_M1_D_STR-BUT_SLD_ROY_PER_S5 sy-vline
WA_ROIUREP_WY_M1_D_STR-SUL_SLD_VOL_W6 sy-vline
WA_ROIUREP_WY_M1_D_STR-SUL_SLD_PPU_W6 sy-vline
WA_ROIUREP_WY_M1_D_STR-SUL_SLD_VAL_W6 sy-vline
WA_ROIUREP_WY_M1_D_STR-SUL_SLD_ROY_PER_W6 sy-vline
WA_ROIUREP_WY_M1_D_STR-SUL_SLD_VOL_S6 sy-vline
WA_ROIUREP_WY_M1_D_STR-SUL_SLD_PPU_S6 sy-vline
WA_ROIUREP_WY_M1_D_STR-SUL_SLD_VAL_S6 sy-vline
WA_ROIUREP_WY_M1_D_STR-SUL_SLD_ROY_PER_S6 sy-vline
WA_ROIUREP_WY_M1_D_STR-REP_IND sy-vline
WA_ROIUREP_WY_M1_D_STR-ST_ROY_PER sy-vline
WA_ROIUREP_WY_M1_D_STR-COUNTY_NM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.