ABAP Select data from SAP table ROIUX1_OK_300R_DL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ROIUX1_OK_300R_DL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ROIUX1_OK_300R_DL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ROIUX1_OK_300R_DL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ROIUX1_OK_300R_DL TYPE STANDARD TABLE OF ROIUX1_OK_300R_DL,
      WA_ROIUX1_OK_300R_DL TYPE ROIUX1_OK_300R_DL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ROIUX1_OK_300R_DL> TYPE ROIUX1_OK_300R_DL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ROIUX1_OK_300R_DL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ROIUX1_OK_300R_DL
  INTO TABLE IT_ROIUX1_OK_300R_DL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ROIUX1_OK_300R_DL
*  INTO TABLE @DATA(IT_ROIUX1_OK_300R_DL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ROIUX1_OK_300R_DL INDEX 1 INTO DATA(WA_ROIUX1_OK_300R_DL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ROIUX1_OK_300R_DL ASSIGNING <ROIUX1_OK_300R_DL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ROIUX1_OK_300R_DL>-RPT_COMP = 1.
<ROIUX1_OK_300R_DL>-SSN = 1.
<ROIUX1_OK_300R_DL>-TAXPAYER_TYPE = 1.
<ROIUX1_OK_300R_DL>-COUNTY_NAME = 1.
<ROIUX1_OK_300R_DL>-PROD_CODE = 1.
ENDLOOP.

LOOP AT IT_ROIUX1_OK_300R_DL INTO WA_ROIUX1_OK_300R_DL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ROIUX1_OK_300R_DL-RPT_MM, sy-vline,
WA_ROIUX1_OK_300R_DL-RPT_YY, sy-vline,
WA_ROIUX1_OK_300R_DL-RPT_TYPE, sy-vline,
WA_ROIUX1_OK_300R_DL-CONTRACT_NO, sy-vline,
WA_ROIUX1_OK_300R_DL-PRODUNIT_NO, sy-vline,
WA_ROIUX1_OK_300R_DL-OP_PU_NO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ROIUX1_OK_300R_DL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ROIUX1_OK_300R_DL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ROIUX1_OK_300R_DL INTO WA_ROIUX1_OK_300R_DL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ROIUX1_OK_300R_DL_STR,
RPT_COMP TYPE STRING,
SSN TYPE STRING,
TAXPAYER_TYPE TYPE STRING,
COUNTY_NAME TYPE STRING,
PROD_CODE TYPE STRING,
RPT_MM TYPE STRING,
RPT_YY TYPE STRING,
RPT_TYPE TYPE STRING,
CONTRACT_NO TYPE STRING,
PRODUNIT_NO TYPE STRING,
OP_PU_NO TYPE STRING,
GROSS_VOL TYPE STRING,
GROSS_VAL TYPE STRING,
DISPOSITION TYPE STRING,
BTU TYPE STRING,
NGPA_CD TYPE STRING,
NGPA_SFX TYPE STRING,
GAS_CODE TYPE STRING,
GRAVITY TYPE STRING,
OIL_TIER_CD TYPE STRING,
OIL_CL_CD TYPE STRING,
ADD_VALUE TYPE STRING,
TAX_REIMB TYPE STRING,
EXEMPT_CD TYPE STRING,
EXEMPT_DEC TYPE STRING,
EXEMPT_VOL TYPE STRING,
EXEMPT_VAL TYPE STRING,
NET_VOL TYPE STRING,
NET_VAL TYPE STRING,
GP_TAX TYPE STRING,
PE_TAX TYPE STRING,
FILLER TYPE STRING,END OF T_EKKO_STR. DATA: WA_ROIUX1_OK_300R_DL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ROIUX1_OK_300R_DL_STR-RPT_COMP sy-vline
WA_ROIUX1_OK_300R_DL_STR-SSN sy-vline
WA_ROIUX1_OK_300R_DL_STR-TAXPAYER_TYPE sy-vline
WA_ROIUX1_OK_300R_DL_STR-COUNTY_NAME sy-vline
WA_ROIUX1_OK_300R_DL_STR-PROD_CODE sy-vline
WA_ROIUX1_OK_300R_DL_STR-RPT_MM sy-vline
WA_ROIUX1_OK_300R_DL_STR-RPT_YY sy-vline
WA_ROIUX1_OK_300R_DL_STR-RPT_TYPE sy-vline
WA_ROIUX1_OK_300R_DL_STR-CONTRACT_NO sy-vline
WA_ROIUX1_OK_300R_DL_STR-PRODUNIT_NO sy-vline
WA_ROIUX1_OK_300R_DL_STR-OP_PU_NO sy-vline
WA_ROIUX1_OK_300R_DL_STR-GROSS_VOL sy-vline
WA_ROIUX1_OK_300R_DL_STR-GROSS_VAL sy-vline
WA_ROIUX1_OK_300R_DL_STR-DISPOSITION sy-vline
WA_ROIUX1_OK_300R_DL_STR-BTU sy-vline
WA_ROIUX1_OK_300R_DL_STR-NGPA_CD sy-vline
WA_ROIUX1_OK_300R_DL_STR-NGPA_SFX sy-vline
WA_ROIUX1_OK_300R_DL_STR-GAS_CODE sy-vline
WA_ROIUX1_OK_300R_DL_STR-GRAVITY sy-vline
WA_ROIUX1_OK_300R_DL_STR-OIL_TIER_CD sy-vline
WA_ROIUX1_OK_300R_DL_STR-OIL_CL_CD sy-vline
WA_ROIUX1_OK_300R_DL_STR-ADD_VALUE sy-vline
WA_ROIUX1_OK_300R_DL_STR-TAX_REIMB sy-vline
WA_ROIUX1_OK_300R_DL_STR-EXEMPT_CD sy-vline
WA_ROIUX1_OK_300R_DL_STR-EXEMPT_DEC sy-vline
WA_ROIUX1_OK_300R_DL_STR-EXEMPT_VOL sy-vline
WA_ROIUX1_OK_300R_DL_STR-EXEMPT_VAL sy-vline
WA_ROIUX1_OK_300R_DL_STR-NET_VOL sy-vline
WA_ROIUX1_OK_300R_DL_STR-NET_VAL sy-vline
WA_ROIUX1_OK_300R_DL_STR-GP_TAX sy-vline
WA_ROIUX1_OK_300R_DL_STR-PE_TAX sy-vline
WA_ROIUX1_OK_300R_DL_STR-FILLER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.